User manual
4-22 N9360A Multi UE Tester CDMA2000 User Manual
4 Operating Procedure
Entering Loss on the Configuration: Test Condition (Loss) Screen
Determine and enter the loss values caused by the antenna
coupler, RF cable, or shield case used to connect the mobile
phone to the Tester. If the Loss is set to
On, these path loss
values are applied to all through the test flow for the band
system being currently tested.
Correction of input/output signal is described in Actual
Input/Output Level and Correction on page 4-19. Also, refer to
Entering Channel Attenuations on the Configuration: Test Sequence
Screen on page 4-23 for the correction of RF test in Automatic
Test.
1 Press the CDMA2000 softkey on the [Top Menu] screen to
activate the cdma2000 system. Refer to Selection of System
on page 4-14 for detail.
2 Press Config > Test Condition > Loss softkeys from the [Initial]
screen to display the [Configuration: Test Condition (Loss)]
screen.
Figure 4-14 [Configuration: Test Condition (Loss)] Screen