User manual
Performance and Specifications 7
N9360A Multi UE Tester CDMA2000 User Manual 7-5
Access Probe Power Measurement
Access Probe Power Measurement specification is shown on
Table 7-7.
Origin Offset Measurement
Origin Offset Measurement specifications are shown on
Table 7-8.
Code Domain Power Measurement
Code Domain Power Measurement specification is shown on
Table 7-9.
Table 7-7 Access Probe Power Measurement
Item Specification Unit Remarks
Input Level –40 to +36 dBm
Table 7-8 Origin Offset
Item Specification Unit Remarks
Input Level –20 to +36 dBm
Measurement Range –20 to –50 dBc Downlink Output Level
: <–50 dBm
Resolution 0.01 dB
Residential Offset ≤–35 dBc
Table 7-9 Code Domain Power Measurement
Item Specification Unit Remarks
Measurement Range –20 to +36 dBm
Resolution 0.1 dB
Accuracy At Code Power reading
≥–10 dBc ±1.5
dB
Downlink Output Level
: <–50 dBm
At Code Power reading
≥–20 dBc ±3.0
Residual ≤–27 dB