User manual

Troubleshooting 6
N9360A Multi UE Tester CDMA2000 User Manual 6-3
Is the Call Drop Timer set to
Off?
Set the Call Drop Timer to On.
Is there interference from the
external noise?
Shut out external noise by using the shield case, etc.
Is the path loss set correctly? Set the path loss between the Tester and the mobile phone
correctly in the Loss field on the [Configuration: Test
Condition (Loss)] screen.
Connection is lost in the
Max TX Power
measurement.
Is BS level too weak? Set the Max Tx Power BS Level to appropriate value.
Is the Call Drop Timer set to
Off?
Set the Call Drop Timer to On.
Is there interference from the
external noise?
Shut out external noise by using the shield case, etc.
Is the path loss set correctly? Set the path loss between the Tester and the mobile phone
correctly in the Loss field on the [Configuration: Test
Condition (Loss)] screen.
Table 6-1 Items to be checked
Symptom Section to be checked Remedy