User manual
Description of Screens 5
N9360A Multi UE Tester CDMA2000 User Manual 5-163
• Limit: Displays the [Configuration: Test Condition (Limit)]
screen.
• Return: Returns to the [Configuration] screen.
Screen Field
Before starting the Automatic Test, Manual Test or TX Analyzer,
set the input items required to execute tests, referring to the
description shown in Table 5-49.
Table 5-49 [Configuration: Test Condition] Screen Input Field (1xEV-DO)
Input Field Description
CDMA Mode Sets the CDMA to either MC-1x or 1xEV-DO. This is the setting for a manual test.
Band Set the band.
• B0:Cel US
• B1:PCS US
• B3:Cel JP
• B4:PCS KR
• B6:IMT-2K
3GPP System
*
Set 3GPP System. The allowable range is as follows:
• 1 to 4 (1 step)
Signaling Pattern
*
Set the signaling pattern. The allowable range is as follows:
• 1 to 255 (1 step)
3GPP2 Config
*
Set 3GPP2 Config. The allowable range is as follows:
• 1 to 4 (1 step)
• The relationship of the setting value for the 3GPP2 Config and the protocol version of
MC-1x and 1xEV-DO is as follows.
Set Value MC-1x 1xEV-DO
1 Rel. 0 Rel. 0
2 Rel. A Rel. 0
3 Rel. 0 Rev. A
4 Rel. A Rev. A