5-160 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
Base Station
*
Set parameters for the base station. The allowable range by item is as follows:
• MCC (Mobile Country Code)
• 0 to 999 (1 step)
• MNC (Mobile Network Code)
• 0 to 99 (1 step)
• NID (Network ID)
• 0 to 65535 (1 step)
• Rgstr NID (Network ID for Zone-based Registration)
• 0 to 65535 (1 step)
• SID (System ID)
• 0 to 32767 (1 step)
• Rgstr SID (System ID for Zone-based Registration)
• 0 to 32767 (1 step)
• Power Up Rgstr (Power Up Registration)
• On/Off
• Max Slot Cycle Index
• 0 to 7 (1 step)
Access Probe
*
Set parameters for the access probe. The allowable range by item is as follows:
• Nom Pwr (Nominal Transmit Power Offset)
• -8 to 7(1 step)
• Init Pwr (Initial Power Offset)
• -16 to 15(1 step)
• Setting Power Step
• 0 to 15(1 step)x0.5dB
• If you turn on Access Probe Pwr Meas, Power Step is disabled and 0 is displayed.
• When you turn off Access Probe Pwr Meas, Power Step is enabled. Values will be
restored (before they were set to ON) and displayed.
• Setting Num Step
1 to 15
• Setting Max Req Seq,Max Rsp Seq (Maximum sequence number of Access Channel
Request/Response)
•1 to 15 (1 step)
Access Probe Pwr Meas Set measurement of Access Probe Power.
• On or Off
Max TX Power BS Level
*
Set BS level to measure Max Power in a manual test.
The allowable range is between -115.0 and -18.0 dBm in 0.1 dB step.
Min TX Power BS Level
*
Set BS level to measure Min Power in a manual test.
The allowable range is between -115.0 and -18.0 dBm in 0.1 dB step.
Table 5-48 [Configuration: Test Condition] Screen Input Field (MC-1x) (continued)
Input Field Description