User manual

Description of Screens 5
N9360A Multi UE Tester CDMA2000 User Manual 5-157
* A changing magnification softkey is available. Refer to Storing Numeric Values and Changing Magnification Softkey.
3GPP System Sets the value for W-CDMA system. This input field exists on the Sequence 1 screen regardless of the
radio system setting.
Table 5-46 Input items on the [Configuration: Test Sequence] (continued)Screen (1xEV-DO)
Input Item Description
Table 5-47 Measurement items on the [Configuration: Test Sequence] Screen (1xEV-DO)
Measurement Item Description
Access Probe Power Sets execution or skip the Access Probe Power measurement.
Inner Loop Power Sets execution or skip the Inner Loop Power measurement.
Max TX Power Sets execution or skip the maximum TX power measurement.
Min TX Power Sets execution or skip the minimum TX power measurement.
Frequency Error Sets execution or skip the Frequency Error measurement.
Multi-code Rho Sets execution or skip the waveform quality (ρ) measurement.
Time Offset Sets execution or skip the transmission timing error measurement.
Sensitivity/ PER1 Sets execution or skip the Sensitivity measurement in PER1. The signal output level
from the Tester and the number of test frames are set on the [Configuration: Test
Condition] screen.
Sensitivity/ PER2 Sets execution or skip the Sensitivity measurement in PER2. The signal output level
from the Tester and the number of test frames are set on the [Configuration: Test
Condition] screen.
Sensitivity/ PER3 Sets execution or skip the Sensitivity measurement in PER3. The signal output level
from the Tester and the number of test frames are set on the [Configuration: Test
Condition] screen.
This item is displayed only when the 3GPP2 Config is set to 3 or 4 (1xEV-DO Rev. A).