User manual

Description of Screens 5
N9360A Multi UE Tester CDMA2000 User Manual 5-155
Screen Field
Set the input items required to execute tests, referring to the
description shown in Table 5-46.
Table 5-45Combination of test item settings (1xEV-DO)
Test step Item Test
1 UATI Assignment Run Run Run Run
2 BS Call Run Run Run Run
3RF Test Run Run
4 Softer Handoff Run Run
5 Connection Close Run Run Run Run
6 Session Close Run Run Run Run
Table 5-46 Input items on the [Configuration: Test Sequence] Screen (1xEV-DO)
Input Item Description
Test items Specifies execution or skip at each step. Refer to Table 5-45, Combination of test item settings
(1xEV-DO).
Radio System Radio system of Sequence No. 1 and 2
Select it from CDMA2000 MC1x and CDMA2000 1xEV-DO. If you do not select radio system for the
sequence-2, set it to ——.
Sequence No Sets the sequence number to set test items.
Detail of RF Test RFCH:
Specifies the band and channel number. The allowable range of channel number for each band is as
follows:
B0 (Cel US): 1024 to 1323 CH, 991 to 1023 CH, 1 to 799 CH
B1 (PCS US): 0 to 1199 CH
B3 (Cel JP): 1041 to 1199 CH, 1201 to 1600 CH, 801 to 1039 CH, 1 to 799 CH
B4 (PCS KR): 0 to 599 CH
B6 (IMT-2K): 0 to 1199 CH
Refer to Appendix B General information on cdma2000 system for details.
ATT In, ATT Out:
Set the path loss value of the coupler and cable connected to the mobile phone.
Refer to Actual Input/Output Level and Correction.
To en abl e c h a n g e s on ATT setting, set Loss on the [Configuration] screen to On.