User manual

5-142 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
Configuration: Test Sequence Screen
When the Tes t Sequence softkey on the [Configuration] screen is
pressed, the [Configuration: Test Sequence] Screen (MC-1x) as
Figure 5-67, the [Configuration: Test Sequence] Screen (3GPP2
Config is set to
1 or 2 (1xEV-DO Rel. 0)) as Figure 5-68 or
[Configuration: Test Sequence] Screen (3GPP2 Config is set to
3
or
4 (1xEV-DO Rev. A)) as Figure 5-69 is displayed.
Set test conditions of Automatic Test on this screen.
Use the connection loss set in the Loss field on the
[Configuration] screen to correct the connection loss between
the tester and the mobile phone for every band. If, on the other
hand, the connection loss depends on the frequency or channel
in one band, the Tester can correct the RF test result with the
attenuation set on this screen.
When the radio system is in MC-1x mode
Figure 5-67 shows the [Configuration: Test Sequence] screen
(MC-1x) when the Radio System is set to CDMA2000 (MC-1x)
mode.
Figure 5-67 [Configuration: Test Sequence] screen (MC-1x)