User manual
Description of Screens 5
N9360A Multi UE Tester CDMA2000 User Manual 5-129
Information is also displayed in the information display area.
The information of Table 5-37 sent from the Tester is displayed
on the screen.
RFCH
*
Specifies the band and channel number. This parameter can be changed when the stand-by or
Connection status.
The allowable range of channel number for each band is as follows:
B0 (Cel US): 1024 to 1323 CH, 991 to 1023 CH, 1 to 799 CH
B1 (PCS US): 0 to 1199 CH
B3 (Cel JP): 1041 to 1199 CH, 1201 to 1600 CH, 801 to 1039 CH, 1 to 799 CH
B4 (PCS KR): 0 to 599 CH
B6 (IMT-2K): 0 to 1199 CH
Refer to Appendix B General information on cdma2000 system for details.
Amplitude
*
Sets the RF output level from the Tester between –115.0 and –18.0 dBm in 0.1 dB steps.
Modulation Sets the Modulation Data to either of the available setting:
• Cont Pilot
• Pilot+MAC+Cntrl
• Pilot+MAC+Cntrl+Tch
Sets Modulation Mode to either of the available setting:
• QPSK
• 8PSK
• 16QAM
when the Modulation Data is set to Pilot+MAC+Cntrl+Tch on the 1xEV-DO mode.
The selectable modulation systems depend on the mode you have selected. For the allowable
combinations of Mode and Modulation system, refer to Appendix D Parameters of physical channels.
Subtype Sets the Subtype. The allowable setting is as follows.
• 0
• 2
Subtype is available when the 3GPP2 Config is set to 3 or 4 (1xEV-DO Rev. A), and the Modulation is set
to Pilot+MAC+Cntrl+Tch.
Averaging Specifies the average number for the TX Power, Frequency Error, Multi-code Rho, Origin Offset, Time
Offset and Code Domain Power measurements.
Sets the averaging number from 2 to 99, or Off.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on
page 4-13.
Table 5-36 Entries on the [TX Analyzer: Stand-by] Code Domain Power Screen (1xEV-DO)
Input Item Description