User manual

5-98 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
W-CDMA: Changes the system to W-CDMA. The W00 Option
is required.
HSDPA: Changes the system to
HSDPA. The W00 and W06
Options are required.
CDMA2000>>: Displays the Softkey Menu 5 to select the
cdma2000 system.
Cancel: Cancels selecting a system and returns to the
Softkey Menu 2.
Softkey Menu 5
MC-1x: Changes the system to the MC-1x mode on the
CDMA Mode. The C00 and C01 Options are required.
1xEV-DO: This softkey is unavailable.
Cancel: Cancels selecting the cdma2000 system and
returns to the Softkey Menu 2.
Screen Field
Set the input fields in the screen field according to the following
description of Table 5-24 to execute a new test.
Table 5-24 Entries on the [Manual Test: Stand-by] Screen (1xEV-DO)
Input Field Description
Measuring
mode
Sets On (measure) or Off (not measure) for each test item group or measurement item.
TX Power
Frequency Error
Multi-code Rho, Origin Offset
Time Offset
PER
Procedure Specifies a parameter file to be used for the test.
This item displays the file name for the parameter file that is currently in use.
It is also possible to select a parameter file from existing parameter files and specify it as the file to be
used for the test.
RFCH
*
Specify the band and channel number. This parameter can be changed when the stand-by or Connection
status.
The allowable range of channel number for each band is as follows:
B0 (Cel US): 1024 to 1323CH, 991 to 1023CH, 1 to 799CH
B1 (PCS US): 0 to 1199CH
B3 (Cel JP): 1041 to 1199CH, 1201 to 1600CH, 801 to 1039CH, 1 to 799CH
B4 (PCS KR): 0 to 599CH
B6 (IMT-2K): 0 to 1199CH