User manual
Description of Screens 5
N9360A Multi UE Tester CDMA2000 User Manual 5-95
Manual RF Test
Table 5-23 describes measurement items of Manual RF Test. The
limit for measurement items can be set on the Configuration:
Test Condition Screen on page 5-158.
Table 5-23 Standard Test Items in 1xEV-DO Manual Test Measurement Item
Test Item Description
TX Power Measures the transmission power of the mobile phone during connection. The measurement
range is from –60 to +36 dBm.
Frequency Error Measures a transmission frequency error of the mobile phone. The measurement range is ±10
kHz.
Multi-code Rho Measures the modulation accuracy (ρ) of transmission waveforms of the mobile phone. The
measurement range is from 0.900 to 0.999.
Origin Offset Measures the origin offset of the mobile phone. The measurement range is from –50.0 to –20.0
dBc.
Time Offset Measures a transmission timing error of the mobile phone. The measurement range is ±10 μsec.
PER Measures the packet error rate of the mobile phone.
Max TX Power Press the maximum transmission power of the mobile phone.
The measurement range is from –60 to +36 dBm.
Min TX Power Press the minimum transmission power of the mobile phone.
The measurement range is from –60 to +36 dBm.
Code Domain Power Measures the power of each code channel (code domain power) of the mobile phone.
NOTE
The value of default status was stored in the internal memory when the
Tester was previously turned off.
A changing magnification softkey to input numerical values will be
enabled. Refer to Storing Numeric Values on page 4-10 and Changing
Magnification Softkey on page 4-13.