User manual
5-68 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
The information from the mobile phone and the Tester as
Table 5-16 is displayed on the screen field.
RFCH
*
Specify the band and channel number. Available in the stand-by or Connection status.
The allowable range for each band is as follows:
• B0:Cel US 1024 to 1323CH, 991 to 1023CH, 1 to 799CH
• B1:PCS US 0 to 1199CH
• B3:Cel JP 1041 to 1199CH, 1201 to 1600CH, 801 to 1039CH, 1 to 799CH
• B4:PCS KR 0 to 599CH
• B6:IMT-2K 0 to 1199CH
• Setting RFCH in the Connection status will start handoff. Handoff is also available between bands.
Refer to Appendix B General information on cdma2000 system for details.
BS Level
*
Sets the RF output level of the Tester, ranging from -115.0 to -18.0 dBm in 0.1 dB step. The
default value is set on the [Configuration: Test Condition] screen.
RX Power Sets On (measure) or Off (not measure) for RX Power measurement.
When this parameter set to on during the Stand-by status and starts the MS call or the BS Call, measure
the RX power once and the Tester display the result.
Averaging Specifies the average number of the measurement of the TX Power, Frequency Error, Waveform Quality
(Rho or multi-code Rho), Origin Offset, Time Offset, Max TX Power, Min TX Power and Code Domain
Power measurement.
Sets the averaging number from 2 to 99, or Off.
PWR CNTL
*
Specify one of the elements of the power control level defined by the radio system.
HOLD| UP| DOWN| CNT UP|CNT DWN
• HOLD: Set to HOLD.
• UP: Set to UP by the specified value. (Not available in the stand-by status.)
• DOWN: Set to DOWN by the specified value. (Not available in the stand-by status.)
• CNT UP: Set to Continuous UP.
• CNT DWN: Set to Continuous DOWN.
This softkey is not available when the voice call (Service Option) is set to 1, 3, 17, or 32768.
Max Frames
*
Specify the number of frames to measure Frame Error Ratio.
The allowable range is as follows: 25 to 10000000
Confidence Selects confidence level of the Frame Error Ratio measurement. Select 95% or Off.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on
page 4-13.