User manual
5-58 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
Table 5-12 lists the items that provide information from the
mobile phone and the Tester.
SCH Level Sets code level of the forward supplemental Channel. This item is displayed only when the Radio Config
is set to F3R3, F4R3, or F5R4 with the Service Option of 32.
The allowable range is as follows:
–20.00 to –2.50 dB (in 0.25 dB steps)
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on
page 4-13.
Table 5-11 Input Items in [Manual Test: Stand-by] Screen (MC-1x)
Input Field Description
Table 5-12 Mobile Phone Information in [Manual Test: Stand-by] Screen (MC-1x)
Item Information Description
IMSI Displays the International Mobile Subscriber Identity sent from the mobile phone, with
maximum 15 digits.
ESN Displays the international mobile station identity sent from the mobile phone, with
maximum 8 digits.
Caller ID Displays dialer number sent from the Tester at BS Call step. Maximum 32 digits,
including arbitrary digits (0 to 9) and symbols (* and #) can be usable. This value can be
changed only by using a remote control command.
Dialed No. Displays the number dialed from the mobile phone at MS Call step.
Pilot Strength Displays the pilot channel measured level at the mobile phone between –31.5 and 0.0 dB
when the mobile phone receives the Measurement Report message.
Radio System Displays CDMA2000 on the lower left of the screen.
RX Power Displays the pilot channel measured level at the mobile phone between –120 to –18
dBm when the mobile phone receives the Pilot Strength Measurement message.
Access Probe Power Measures and displays the access probe power when receiving an access probe before
connection. The display range is -60.0 to 36.0 dBm
• Turning Setting off on the [Configuration: Test Condition] screen will disable the
measurement and display.
3GPP-SYS Displays the value for 3GPP System that is set in the [Configuration: Test Sequence] and
the [Configuration: Test Condition] screens.
SIG-PTN Displays the value for Signaling Pattern that is set in the [Configuration: Test Condition]
screen.
3GPP2-CONF Displays the value for 3GPP2-Config that is set in the [Configuration: Test Condition]
screen.