5-56 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
RFCH
*
Specifies the band and channel number. This parameter can be changed when in the stand-by or
Connection status.
The allowable range of channel number for each band is as follows:
• B0(Cel US): 1024 to 1323CH, 991 to 1023CH, 1 to 799CH
• B1(PCS US): 0 to 1199CH
• B3(Cel JP): 1041 to 1199CH, 1201 to 1600CH, 801 to 1039CH, 1 to 799CH
• B4(PCS KR): 0 to 599CH
• B6(IMT-2K): 0 to 1199CH
Refer to Appendix B, Channel frequency and channel number for details.
BS Level
*
Sets the RF output level of the Tester, ranging from -110.0 to -50.0 dBm in 0.1 dB steps. The
default value is set on the [Configuration: Test Condition] screen.
Service Option Specify the service options. The selectable service options are limited depending on the Radio Config
setting. Changing Radio Config setting will lead the previously specified service option to be set. This
parameter cannot be changed during connection status.
The allowable types are as follows:
1: Normal Voice
2: 9.6k Data Loop Back
3: EVRC 9.6k Voice
9: 14.4k Data Loop Back
17: 14.4k Voice
32: TDSO
55: Data Loop Back
32768: 14.4k Voice
• Setting the Service Option 32 will display the measurement item TDS0 FER; selecting others will
display FER.
Refer to Ta b l e A- 2 , “Relation between Radio Config and Service Option,” on page 20 for details.
RX Power Sets On (measured) or Off (not measured) for Rx Power Measurement. This parameter can be set in
Stand-by state and Connection State.
Caller ID Sets Caller ID notification to On or Off.
• On: Caller ID notified
• Off: Caller ID not notified
When setting the Caller ID notification to ON, the Tester notifies the Caller ID to the mobile phone at BS
Call step.
Averaging Specifies the average number of the measurement of the TX Power, Frequency Error, Waveform Quality
(Rho or multi-code Rho), Origin Offset, Time Offset, Max TX Power, Min TX Power and Code Domain
Power measurement.
Set the average number of times to 2 to99 or Off.
Table 5-11 Input Items in [Manual Test: Stand-by] Screen (MC-1x)
Input Field Description