User manual

5-54 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
The measurement is terminatedends when the trigger
mode is changed from
Cont to Sing.
Trigger: Starts measurement during the Connection status.
This softkey is inactivated in the stand-by status but
activated in the connection status.
More (1 of 3): Displays the softkey menu 2.
Return: Returns to the [Initial] screen.
Softkey Menu 2
Print Screen: Prints a hardcopy of the screen or saves a
graphic file of the screen in a USB memory device
depending on the setting of the Printer input field on the
[Configuration] screen.
RF Output On/Off: Selects the RF power output from
On and
Off. When it is set to On, the Tester outputs the BS level of
the signal. When it is set to
OFF, the Tester outputs less
than –120 dBm of the signal..
System >>: Displays the Softkey Menu 4 to select a system.
Code Power: Displays the [Code Domain Power]
measurement screen. This softkey displayed when the
Service Option is set to 2, 9, 32, or 55 and the Radio Config is
set to F3R3, F4R3 or F5R4.
More (2 of 3): Displays the Softkey Menu 3.
Softkey Menu 3
Debug Data > USB: Stores the debug data into the USB
memory device.
Call Drop Timer On/Off: Sets Call Drop Timer to
On or Off.
More (3 of 3): Displays the Softkey Menu 1.
Softkey Menu 4
GSM: Changes the system to GSM. The G00 option is
required.
GPRS: Changes the system to
GPRS. Installation for G00
Option is required.
EGPRS: Changes the system to
EGPRS. Installation for G00
Option and G03 Option is required.