User manual
5-52 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
RF Test with Manual Test
Table 5-10 describes measurement items of RF test. The limit for
measurement items can be set on the [Configuration: Test
Condition] screen. Refer to Configuration: Test Condition
Screen on page 5-158.
Table 5-10 Manual Test: Measurement Items (MC-1x)
Input Field Description
TX Power Measures the transmission power of the mobile phone
during connection. The measurement range is from -60
to +36 dBm.
Frequency Error Measures a transmission frequency error of the mobile
phone. The measurement range is ±10kHz.
Rho/Multi-code Rho Measures the modulation accuracy (ρ) of transmission
waveforms of the mobile phone. The measurement
range is from 0.900 to 0.999.
Origin Offset Measures the origin offset. The measurement range is
from –50.0 to –20.0 dBc.
Time Offset Measures the transmission timing error of the mobile
phone. The measurement range is ±10 μsec.
FER/TDSO FER Measures the frame error ratio of the mobile phone.
Max TX Power Press the Max & Min Power softkey to measure the
maximum transmission power of the mobile phone.
The measurement range is from –60 to +36 dBm.
Min TX Power Press the Max & Min Power softkey to measure the
minimum transmission power of the mobile phone.
The measurement range is from –60 to +36 dBm.
Code Domain Power Measures the power of each code channel (code
domain power) of the mobile phone.