User manual
5-38 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
• Abort: Aborts the measurement and returns to the
[Stand-by] screen.
Softkey Menu 2
• Simple: Displays a Pass/Fail result of whole measurement
in the center of the measurement result field in zoom.
• Detail: Displays a Pass/Fail result at each item cell in the
measurement result field.
• Value: Displays a measurement value at each item cell in
the measurement result field.
• Cancel: Cancels changing the display mode and returns to
the softkey menu 1.
Screen Field
The information from the mobile phone as Table 5-7 is displayed
in the screen field
Message Field
The following message is displayed on [Measuring] screens:
Press the desired softkey.
Table 5-7 Items that provide information from the Mobile Phone and the Tester on the [Automatic Test:
Measuring] Screen (MC-1x)
Item Information Description
IMSI Displays the International Mobile Subscriber Identity sent from the mobile phone.
ESN Displays the international mobile station identity that is sent from the mobile phone.
Caller ID Displays dialer number sent from the Tester at BS Call step. Maximum 32 digits, including
arbitrary digits (0 to 9) and symbols (* and #) can be usable. This value can be changed only by
using a remote control command.
Dialed No. Displays the number dialed from the mobile phone at MS Call step.
3GPP-SYS Displays the value of the 3GPP System that is set on the [Configuration: Test Sequence] and the
[Configuration: Test Condition] screens.
SIG-PTN Displays the value of the Signaling Pattern that is set on the [Configuration: Test Condition]
screen.
3GPP2-CONF Displays the value of the 3GPP2-Config that is set on the [Configuration: Test Condition] screen.