5-34 N9360A Multi UE Tester CDMA2000 User Manual
5 Description of Screens
The input fields of parameters except procedure are protected if
the Panel Key is set to
Lock on the [Configuration] screen.
Set the input fields in the screen field according to the following
description of Table 5-18 to execute a new test. The file name
for the file currently in use will be displayed in this item.
The information from the mobile phone as Table 5-6 is displayed
in the screen field.
Table 5-5 Input Items on the [Auto Test: Stand-by] Screen (MC-1x)
Input Field Description
Procedure Specify a parameter file to be used for the test.
This item displays the file name for the parameter file that is currently in use.
It is also possible to select a parameter file from existing parameter files and specify it as the file to be
used for the test.
RFCH
*
Specify the band and channel number. This parameter can be changed when in the stand-by status.
The allowable range of channel number for each band is as follows:
• B0:Cel US 1024 to 1323CH, 991 to 1023CH, 1 to 799CH
• B1:PCS US 0 to 1199CH
• B3:Cel JP 1041 to 1199CH, 1201 to 1600CH, 801 to 1039CH, 1 to 799CH
• B4:PCS KR 0 to 599CH
• B6:IMT-2K 0 to 1199CH
• "----":Skip
Refer to Appendix B General information on cdma2000 system for details.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on
page 4-13.
Table 5-6 Items that provide information from the Mobile Phone and the Tester on the [Automatic Test: Stand-by]
Screen (MC-1x)
Item Information Description
IMSI Displays the International Mobile Subscriber Identity sent from the mobile phone, with Max. 15
digits. If the state is Stand-by and IMSI information has not been received, data from the
procedure file (dummy data) is displayed.
ESN Displays the international mobile station identity that is sent from the mobile phone, with Max. 8
digits. This number is not displayed when the state is Stand-by.
Caller ID Displays dialer number sent from the Tester at BS Call step. Max. 32 digits, including arbitrary
digits (0 to 9) and symbols (* and #) can be displayed usable. This value can be changed only by
using a remote control command.
Dialed No. Displays the number dialed from the mobile phone at MS Call step.