Agilent N9360A Multi UE Tester CDMA2000 User Manual Agilent Technologies
Notices © Agilent Technologies, Inc. 2008 Manual Part Number No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. N9360-90706 Edition Second Edition, March 2008 Printed in Malaysia Agilent Technologies Microwave Products (Malaysia) Sdn. Bhd.
Preface Thank-you for purchasing the Agilent N9360A Code Division Multiple Access (cdma2000) Option. This option is the cdma2000 software for the Agilent N9360A Multi UE Tester. • Before using the tester, the user is advised to read this manual carefully to ensure correct usage and also to fully utilize the tester capability. • This manual is a reference document and the user is advised to keep it carefully for future reference.
Trademarks • Ethernet is the registered trademark of the Xerox Corporation. • EPSON is the registered trademark of the EPSON Corporation. • cdma2000 is a registered trademark of the telecommunications Industry Association (TIA-USA). • Other product names and companies used herein are trademarks or registered trademarks of their respective companies or Agilent Technologies, Inc. For registered trademarks, the trademarks symbols ® and ™ are omitted in this manual.
DECLARATION OF CONFORMITY According to EN ISO/IEC 17050-1:2004 Generic example Manufacturer’s Name: Manufacturer’s Address: Agilent Technologies Microwave Products (M) Sdn.
Product Regulations EMC Performance Criteria IEC 61326-1:2002 / EN 61326-1:1997+A1:1998+A2:2001+A3:2003 CISPR 11:1990 / EN 55011:1990 – Group 1 Class A IEC 61000-4-2:1995 / EN 61000-4-2:1995 (ESD 4kV CD, 8kV AD) IEC 61000-4-3:1995 / EN 61000-4-3:1996 (3V/m, 80% AM) IEC 61000-4-4:1995 / EN 61000-4-4:1995 (EFT 0.5kV line-line, 1kV line-earth) IEC 61000-4-5:1995 / EN 61000-4-5:1995 (Surge 0.5kV line-line, 1kV line-earth) IEC 61000-4-6:1996 / EN 61000-4-6:1996 (3V, 0.
Contents Preface 1-3 Notation 1-3 Notices 1-3 Trademarks 1-4 1 Legal Information Legal Information 1-2 Warranty 1-2 Technology Licenses 1-2 Restricted Rights Legend 1-2 Service And Support 1-3 Agilent On The Web 1-3 Agilent By Phone 1-3 Table 1-1. Agilent Call Centers and Regional Headquarters 2 Caution and Safety Requirements Safety Information 2-2 Safety Summary 2-2 Safety Notices 2-2 Warning Label 2-2 General 2-3 When Operating The Tester 3 1-3 2-3 Overview Functions 3-2 Table 3-1.
4 Operating Procedure Test Flow 4-2 Figure 4-1. Test Flow 4-2 Preparation for Each Test 4-3 System Requirement 4-3 Figure 4-2. Typical Test Setup of the Tester 4-3 Connection 4-3 Figure 4-3. Connecting a Printer 4-5 Figure 4-4. Connecting a USB-GPIB Converter 4-6 Test Procedure 4-7 Activating the Tester 4-7 General Operation 4-7 Figure 4-5. Display Annotation 4-7 Table 4-1. Description of the Display Annotation 4-8 Figure 4-6. Value Storage Softkeys 4-10 Figure 4-7. Memory Function 4-11 Figure 4-8.
Figure 4-27. [Configuration: Test Condition (Limit)] Screen 4-36 Figure 4-28. [Manual Test: Stand-by] Screen (MC-1x) 4-37 Figure 4-29. [Manual Test: Measuring] Connection Screen (MC-1x) 4-38 Figure 4-30. [Manual Test: Measuring] Result Screen (MC-1x) 4-39 Figure 4-31. [Manual Test: Measuring] Max & Min TX Power Summary Screen (MC-1x) 4-40 Figure 4-32. [Manual Test] Code Domain Power Result Screen (MC-1x) 4-41 Figure 4-33.
Figure 4-59. [TX Analyzer: Stand-by] Result Screen 4-70 Testing a Mobile Phone by Signal Generator 4-71 Figure 4-60. [Initial] Screen 4-71 Figure 4-61. [Configuration: Test Condition (Loss)] Screen 4-72 Figure 4-62. [Signal Generator] Screen 4-72 Ending a Test 4-74 Disconnecting the Mobile Phone 5 4-74 Description of Screens Screen Structure 5-2 Figure 5-1. Screen Structure 5-2 Top Menu Screen 5-3 Figure 5-2. Top Menu Structure Figure 5-3.
Stand-by Screen 5-31 Figure 5-14. [Auto Test: Stand-by] Simplified Screen (MC-1x) 5-31 Figure 5-15. [Auto Test: Stand-by] Detailed Screen (MC-1x) 5-32 Figure 5-16. [Auto Test: Stand-by] Value Screen (MC-1x) 5-32 Table 5-5. Input Items on the [Auto Test: Stand-by] Screen (MC-1x) 5-34 Table 5-6. Items that provide information from the Mobile Phone and the Tester on the [Automatic Test: Stand-by] Screen (MC-1x) 5-34 Measuring Screen 5-36 Figure 5-17.
Figure 5-31. [Manual Test: Measuring] MS Call Connection Screen (MC-1x) 5-62 Table 5-13. Input Items on [Manual Test] Connection Screen (MC-1x) 5-63 Table 5-14. Mobile Phone Information on [Manual Test: Measuring] Screen (MC-1x) 5-65 Figure 5-32. [Manual Test: Measuring] Code Domain Power Screen (MC-1x) 5-66 Table 5-15. Input Items on [Manual Test: Measuring] Code Domain Power Measurement Screen (MC-1x) 5-67 Table 5-16.
Figure 5-47. [Automatic Test: Stand-by] Result Value Screen (1xEV-DO) 5-91 Table 5-21. Input Items on [Automatic Test: Stand-by] Result Screen (1xEV-DO) 5-92 Table 5-22. Mobile-Phone Information on [Automatic Test: Stand-by] Result Screen (1xEV-DO) 5-93 Manual Test (1xEV-DO Mode) 5-94 Overview 5-94 Manual RF Test 5-95 Table 5-23. Standard Test Items in 1xEV-DO Manual Test Measurement Item 5-95 Stand-by Screen 5-96 Figure 5-48. [Manual Test: Stand-by] Screen (1xEV-DO) 5-96 Table 5-24.
Measuring Screen 5-120 Figure 5-55. [TX Analyzer: Measuring] Screen 5-120 Result Screen 5-121 Figure 5-56. [TX Analyzer: Stand-by] Result Screen 5-121 Code Domain Power Measuring Screen (MC-1x Mode) 5-123 Figure 5-57. [TX Analyzer: Stand-by] Code Power Screen (MC-1x Mode) 5-123 Table 5-34. Entries on the [TX Analyzer: Stand-by] Code Domain Power Screen (MC-1x) 5-124 Table 5-35.
Table 5-44. Input items on the [Configuration: Test Sequence] Screen (MC-1x) 5-152 Figure 5-68. [Configuration: Test Sequence] Screen (3GPP2 Config is set to 1 or 2 (1xEV-DO Rel. 0)) 5-153 Figure 5-69. [Configuration: Test Sequence] Screen (3GPP2 Config is set to 3 or 4 (1xEV-DO Rev. A)) 5-154 Table 5-45. Combination of test item settings (1xEV-DO) 5-155 Table 5-46. Input items on the [Configuration: Test Sequence] Screen (1xEV-DO) 5-155 Table 5-47.
Figure 5-85. [Configuration: File Management] Delete-1 screen 5-183 Figure 5-86. [Configuration: File Management] Delete-2 screen 5-184 Figure 5-87. [Configuration: File Management] Delete-3 screen 5-185 File Replace Confirmation screen (when HDD selected) 5-186 Figure 5-88. File Replace Confirmation screen (HDD) 5-186 File Replace Confirmation screen (USB Memory Device is selected) 5-188 Figure 5-89.
Table 7-15. Minimum TX Power Measurement Table 7-16. Access Probe Power Measurement Table 7-17. Origin Offset 7-9 Table 7-18. Code Domain Power Measurement A 7-8 7-9 7-9 Appendix A Input Items and Allowable Options or Ranges Table A-1. Input fields and allowance choices or ranges A-2 Table A-2. Relation between Radio Config and Service Option A-20 B Appendix B General information on cdma2000 system Channel frequency and channel number Table B-1. RF channel B-2 Frequency band B-2 Table B-2.
xii N9360A Multi UE Tester CDMA2000 User Manual
Agilent N9360A Multi UE Tester CDMA2000 User Manual 1 Legal Information Warranty 1-2 Technology Licenses 1-2 Restricted Rights Legend 1-2 Service And Support 1-3 Agilent On The Web 1-3 Agilent By Phone 1-3 Agilent Technologies 1-1
1 Legal Information Legal Information Warranty The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.
Legal Information 1 Service And Support Any adjustment, maintenance, or repair of this product must be performed by qualified personnel. Contact your customer engineer through your local Agilent Technologies Service Center. Agilent On The Web You can find information about technical and professional services, product support, and equipment repair and service on the Web: http://www.agilent.com/ Double-click the link to Test & Measurement. Select your country from the drop-down menus.
1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK 1-4 N9360A Multi UE Tester CDMA2000 User Manual
Agilent N9360A Multi UE Tester CDMA2000 User Manual 2 Caution and Safety Requirements Safety Summary 2-2 Safety Notices 2-2 Warning Label 2-2 General 2-3 When Operating The Tester 2-3 Agilent Technologies 2-1
2 Caution and Safety Requirements Safety Information Safety Summary The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies, Inc. assumes no liability for the customer's failure to comply with these requirements.
Caution and Safety Requirements 2 General WA RNING The protection provided by the Agilent N9360A Tester may be impaired if the tester is used in a manner not specified by Agilent or the instructions on the display are not followed. WA RNING DO NOT INSTRUMENT COVERS. Operating personnel must not remove any instrument covers. Component replacement and internal adjustments must be made only by qualified service personnel.
2 Caution and Safety Requirements THIS PAGE IS INTENTIONALLY LEFT BLANK.
Agilent N9360A Multi UE Tester CDMA2000 User Manual 3 Overview Functions 3-2 Features 3-4 Configuration 3-5 Options 3-6 Accessories 3-6 This chapter outlines the feature of the CDMA2000 Option. For functions of the GSM Option, refer to the N9360A Multi UE Tester GSM User Manual, and for functions of the W-CDMA Option, refer to the N9360A Multi UE Tester W-CDMA User Manual.
3 Overview The CDMA2000 Option for the N9360A Multi UE Tester supports the Protocol and RF performance tests to inspect mobile phones in the process of production, service, repair and maintenance. The N9360A can carry out the radio performance tests including call processes. In addition, it provides TX Analyzer function which offer RF radio performance tests without call processes and Signal Generator function to adjust radio parts.
3 Overview Table 3-1 Main Functions Option Function cdma2000 (continued) Radio Performance Test MC-1x (Option C01) TX Power Measurement Frequency Error Measurement Rho/Multi-code Rho Measurement Origin Offset Measurement Maximum TX Power Measurement Minimum TX Power Measurement Time Offset Measurement Sensitivity/FER Measurement, Sensitivity/TDSO FER Measurement 1 Code Domain Power Measurement TX Power 2 Pilot 2 Traffic (Fundamental) 2 Max Inactive Channel 2 Access Probe Power Measurement Inner Loop P
3 Overview Table 3-1 Main Functions Option Function Remote Control Ethernet Serial (Option E01) GP-IB (Option E02) 1. The measurement is valid only when the Radio Configuration is set to F3R3, F4R3 and F5R4 and the Service Option is set to 32. 2. The measurement is valid only when the Radio Configuration is set to F3R3, F4R3 and F5R4. 3. The measurement is valid only when the 3GPP2 Config is set to 3 or 4 (1xEV-DO Rev. A).
3 Overview Extensive Interface Options The N9360A Tester offers various interface options including Ethernet, USB, GP-IB (Option E02) and Serial (Option E01). The USB ports are offered to connect a printer, a USB-GPIB converter (Option E02), or a USB memory device for firmware update or parameter saving/recalling. Ethernet, GP-IB, and Serial are used for remote control.
3 Overview Options Table 3-3 shows the options of the Tester. For the specification of the options, contact the Agilent Sales Department or an approved distributor. Table 3-3 Options Item Name Type Remarks CDMA2000 Band15:AWS C03 Band15: Advanced Wireless Services Serial Port E01 DSub 9-pin male connector USB-GPIB Converter E02 Use a USB interface IEEE 24 pin connector (Amphenol) cdma2000 PoST 1 E05 PoST software for cdma2000 1.
Overview 3 THIS PAGE IS INTENTIONALLY LEFT BLANK.
3 3-8 Overview N9360A Multi UE Tester CDMA2000 User Manual
Agilent N9360A Multi UE Tester CDMA2000 User Manual 4 Operating Procedure Test Flow 4-2 Preparation for Each Test Test Procedure 4-7 Ending a Test 4-74 4-3 This chapter describes the preparations required and the operating procedures before starting the test of the CDMA Mobile Unit.
4 Operating Procedure Test Flow This section describes a test flow to inspect the Mobile Unit with the CDMA2000 Option (MC-1x mode: Option C01, 1xEV-DO mode: Option C02). Figure 4-1 shows the test operation flow. Subsequently, the mobile phone operation method is described according to the test flow. Figure 4-1 Test Flow 2.2.1 System Requirement 2.2.2 Installing the Test SIM 2.3.1 Activating the Tester 2.3.3 Selection of System cdma2000 GSM 2.3.
Operating Procedure 4 Preparation for Each Test CAUTION Make sure that the input signal level does not exceed the maximum level allowed. Otherwise, an accident or Tester failure may occur. The following procedures are required before starting each test. System Requirement The following equipment are required to set up a test system: • The Agilent N9360A Multi UE Tester. • An RF cable, RF antenna coupler (type N9360A-A02) to connect RF signals from/to the mobile phone under test.
4 Operating Procedure 2 Using a User-Supplied RF Cable If you have a cable which connects between the RF port of the mobile phone and the RF IN/OUT connector of the Tester, use it instead of the Antenna Coupler. 3 Using the Shield Case Connect the ANTENNA COUPLER IN/OUT connector of the shield case (type N9360A-S01) to the RF IN/OUT connector on the front panel of the Tester. Place the mobile phone on the antenna coupler board inside the shield case using the horizontal and vertical holders.
Operating Procedure 4 Figure 4-3 Connecting a Printer Agilent N9360A Multi UE Tester USB Connector Printer USB Interface Connector Printer Cable Using a USB Memory Device To save graphic files of screen in a USB memory device, connect the USB memory device to the USB connector on the front panel of the Tester. Graphic files are saved in Portable Network Graphics (PNG) format and with a file name: COPY and the number from 00 to 99 which automatically increases.
4 Operating Procedure Figure 4-4 Connecting a USB-GPIB Converter Agilent N9360A Multi UE Tester USB Connector GP-IB (USB) FL USB-GPIB Converter USB Cable 4-6 N9360A Multi UE Tester CDMA2000 User Manual
4 Operating Procedure Test Procedure Activating the Tester To activate the Tester, turn on the LINE switch on the rear panel of the Tester and press the LINE switch on the front panel. NOTE Provide warm up of 30 minutes or more to ensure correct measurement. General Operation Display Annotation Depending on functions and test situations, there are several types of screen. Figure 4-5 shows the common areas on the typical screen.
4 Operating Procedure Table 4-1 Description of the Display Annotation No. Name Description 1 Function Mode Field The current function mode, for example, Automatic Test, Manual Test, TX Analyzer and Configuration, is displayed in this field. 2 Status Display Field The current operation status, for example, Stand-by, Measuring, Test Sequence and Test Condition, is displayed in this field. 3 Date/Time Field The current date and time are displayed in this field.
Operating Procedure 4 move it upward or left, and place it next to the input field you want to change. 2 Press the CURSOR CONTROL knob once. The highlighted input field changes to normal display and circular cursor changes to a triangular one. 3 Rotate the CURSOR CONTROL knob clockwise or counterclockwise to find the values to specify for it. 4 Press the CURSOR CONTROL knob to enter the desired value in the input field.
4 Operating Procedure Storing Numeric Values For numeric input fields such as channel numbers and relevancies of amplitude, you can store up to four numeric values into the memory softkey menus with the following procedure: 1 Move the cursor to one of the numeric input fields of channels and relevancies of amplitude. 2 Press the CURSOR CONTROL knob to select the field. The softkey menu as Figure 4-6 is displayed on the screen.
4 Operating Procedure 4 Press the Store Value to Memory >> softkey. The softkey menu including Memory 1, Memory 2, Memory 3 and Memory 4 softkeys as shown in Figure 4-7. Figure 4-7 Memory Function 5 Press one of the memory softkeys from Memory 1 to Memory 4 where you desire to store that value. 6 The memory softkey menu returns to the state in step 2 showing the value newly stored. 7 Press the CURSOR CONTROL knob to set the value into the field. The softkey menu returns to that of step 1.
4 Operating Procedure Recalling Numeric Values 1 Move the cursor to one of the numeric input fields of channels or relevancies of amplitude. 2 Press the CURSOR CONTROL knob to select the field. The softkey menu displayed as shown in Figure 4-8. The four memory softkeys show the values previously stored in the memories if any. Figure 4-8 Value Storage Softkeys Channel Output Level 3 Press Memory 1, Memory 2, Memory 3 or Memory 4 softkey to enter the stored value to the field.
4 Operating Procedure Changing Magnification Softkey Press the CURSOR CONTROL knob to select a numeric input field, such as channels and relevancies of amplitude. A changing magnification softkey as in Figure 4-9 is displayed with memory softkeys. A selected magnification is underlined. Figure 4-9 Changing Magnification Softkey Pressing this softkey changes the multiplier from 1 to 1000.
4 Operating Procedure Selection of System On this screen, select a system from GSM, W-CDMA or cdma2000. NOTE This N9360A CDMA2000 User Manual describes only the cdma2000 system. Refer to the N9360A GSM User Manual for GSM system and the N9360A W-CDMA User Manual for W-CDMA system. 1 Turn on the Tester. The [Top Menu] screen is displayed as Figure 4-10.
4 Operating Procedure 2 Press the CDMA2000 softkey to select the cdma2000 system. The [Initial] screen for cdma2000 is displayed after the Tester completes its initialization and self-test routine.Figure 4-11 shows the [Initial] screen of the MC-1x mode. When shifting the 1xEV-DO mode, press the CDMA Mode>>, 1xEV-DO softkey. (See Figure 4-12) Or, specify the CDMA Mode field on the [Configuration: Test Condition] screen obtained to press the Config and Test Condition softkeys.
4 Operating Procedure Figure 4-12 [Initial] Screen 1xEV-DO Mode NOTE When the Autoboot function is set to FUNC GSM, FUNC WCDMA or, FUNC CDMA2000, the Tester will automatically select the GSM, W-CDMA or cdma2000 system mode if no softkey is pressed within the specified time (10 to 60 seconds). When the Tester is shipped, the AutoBoot function is set to None.
4 Operating Procedure Selection of the Function Mode on the Initial Screen Press one of the softkeys to select a function mode. Figure 4-13 [Initial] Screen MC-1x Mode Softkey Menu Field Softkey menu 1 • Automatic Test: Starts the Automatic Test. Refer to Testing a Dual Band Mobile Phone by Automatic Test (MC-1x Mode) and Tests using 1xEV-DO Mode(Option C02). • Manual Test: Starts the Manual Test.
4 Operating Procedure • Config: Displays the [Configuration] screen to set parameters. Refer to Configuration. Softkey menu 2 • Print Screen: Prints the screen hard-copy or stores the screen image in the USB memory device, according to the Printer field setting on the [Configuration] screen. • Return to Menu: This softkey is not for selecting a function mode. The screen returns to the [Top Menu] screen when this softkey is pressed. Refer to Return to Menu Screen for detail.
4 Operating Procedure Correction Actual Input/Output Level and Correction 1 Actual Output Level and Correction in Automatic Test (Except RF test), Manual Test, and Signal Generator Output signal level of the Tester is corrected according to cable loss, coupling loss, and etc. Some of parameters should be set properly.
4 Operating Procedure InputLevel = MsLevel + LossRFIn Where, InputLevel = Corrected measured value of the Tester. MsLevel = Input signal level of the mobile phone at the RF IN/OUT connector. LossRfIn = Setting value at the RF In field on the [Configuration: Test Condition (Loss)] screen. 3 Actual Output Level and Correction for RF Test in Automatic Test Output signal level of the Tester is corrected according to cable loss, coupling loss, and etc. Some of parameters should be set properly.
4 Operating Procedure 4 Actual Input Signal Level and Correction for RF Test in Automatic Test Input signal level of the Tester (for uplink signal) is corrected according to cable loss, coupling loss, and etc. Some of parameters should be set properly. The measurement results of RF test in the Automatic Test mode are corrected by the following equation. InputLevel = MsLevel + LossRFIn + AttIn Where, InputLevel = Corrected measured value of the Tester.
4 Operating Procedure Entering Loss on the Configuration: Test Condition (Loss) Screen Determine and enter the loss values caused by the antenna coupler, RF cable, or shield case used to connect the mobile phone to the Tester. If the Loss is set to On, these path loss values are applied to all through the test flow for the band system being currently tested. Correction of input/output signal is described in Actual Input/Output Level and Correction on page 4-19.
4 Operating Procedure 3 Set the Loss field to On with the CURSOR CONTROL knob. 4 Enter the appropriate loss values, depending on the band, in the RF In and RF Out fields with the CURSOR CONTROL knob. These loss values are used all through the test flow. 5 Press the Return softkey to return to the [Initial] screen. Entering Channel Attenuations on the Configuration: Test Sequence Screen This section describes correction for RF test results in Automatic Test.
4 Operating Procedure Figure 4-15 [Configuration: Test Sequence)] Screen 3 Enter the appropriate attenuation values, depending on the traffic channel, in the ATT In and ATT Out fields with the CURSOR CONTROL knob. These values are effective for the RF tests in the test flow. 4 Press the Return softkey twice to return to the [Initial] screen.
4 Operating Procedure Testing a Dual Band Mobile Phone by Automatic Test (MC-1x Mode) This section describes the operation method of the Tester and a dual band (B1:PCS US and B0:Cel US) mobile phone under the test by Automatic Test MC-1x mode. This section shows the example of the Tester operation to test the mobile phone supporting B1:PCS US and B0:Cel US by using the Automatic Test mode. The handover from the B1:PCS US and B0:Cel US is performed during the test.
4 Operating Procedure Figure 4-17 [Configuration: Test Condition (Loss)] Screen 4 Press the Return softkey twice and then the Test Sequence softkey to display the [Configuration: Test Sequence] screen for required setting in Automatic Test.
Operating Procedure 4 Figure 4-18 [Configuration: Test Sequence1] Screen Figure 4-19 [Configuration: Test Sequence2] Screen N9360A Multi UE Tester CDMA2000 User Manual 4-27
4 Operating Procedure 5 Set CDMA2000 MC-1x in Radio System 1 and 2, and set other fields as shown in Figure 4-18 and Figure 4-19. 6 Set Run at test item field which you want to execute in the test flow. Set Run at measurement item cell which you want to measure in the measurement item table. 7 Press the Return and then the Test Condition softkey to display the [Configuration: Test Condition] screen as Figure 4-20 to set the test condition.
4 Operating Procedure Figure 4-21 [Configuration: Test Condition (Limit)] Screen 11 Set appropriate test limits in the cells of the test item table in the upper right side of Figure 4-21. 12 Repeat step 11 to set the test condition for Cel US after replacing B1:PCS US to B0:Cel US at the Band field. 13 Press the Return softkey three times and then the Automatic Test softkey to start Automatic Test. The [Auto Test: Stand-by] screen as Figure 4-22 is displayed.
4 Operating Procedure Figure 4-22 [Automatic Test: Stand-by] Value Screen (MC-1x) 14 Press the Start softkey to start a test. A screen status changes from Stand-by to Measuring. 15 Turn the mobile phone on. Wait for the mobile phone to camp on, and P is shown at the Location Update step. 16 At the MS Call step, make a call from the mobile phone. Dial an arbitrary number and press the Off Hook button on the mobile phone.
4 Operating Procedure 20 At the Talk step, check the quality of loop back voice and press the Pass or the Fail softkey according to its result. 21 At the BS Release step, the Tester automatically finishes the call. 22 At the BS Call (RF Test) step, the mobile phone automatically responds to the call from the Tester. 23 As each step is running in the test flow, the corresponding test item field in the table is highlighted.
4 Operating Procedure 26 If a printer is available, print the test results. Press the More (1 of 2) softkey, and then the Print Screen softkey to print a screen hardcopy. 27 Press the More (2 of 2) softkey to return to the previous softkey menu. 28 If you want to repeat the same test again, press the Start softkey.
4 Operating Procedure Testing a Dual Band Mobile Phone by Manual Test (MC-1x Mode) This section describes the operation method of the Tester and a dual band (B1: PCS US and B0: Cel US) mobile phone under the test by the Manual Test MC-1x mode. This section shows the example of the Tester operation to test the mobile phone supporting B1:PCS US and B0:Cel US by using the Manual Test mode. 1 Turn on the Tester and select the cdma2000 system on the [Top Menu] screen.
4 Operating Procedure [Configuration: Test Condition (Loss)] screen specifying the Loss value. Refer to Entering Loss on the Configuration: Test Condition (Loss) Screen on page 4-22. Figure 4-25 [Configuration: Test Condition (Loss)] Screen 4 Press the Return softkey to display the [Configuration: Test Condition] screen for required setting in Manual Test MC-1x mode.
4 Operating Procedure Figure 4-26 [Configuration: Test Condition] Screen 5 Select MC-1x at the CDMA Mode field with the CURSOR CONTROL knob. This value might be set to MC-1x, if the operation of step 2 is proceeded. 6 Set the SID and Rgstr SID fields for requiring number of the mobile phone. 7 Press the Limit softkey to display the [Configuration: Test Condition (Limit)] Screen as Figure 4-27.
4 Operating Procedure Figure 4-27 [Configuration: Test Condition (Limit)] Screen 8 Set the appropriate test limits in the cells of the test item table in the right side of the Figure 4-27. 9 Press the Return softkey three times and then the Manual Test softkey to start Manual Test. The [Manual Test: Stand-by] Screen (MC-1x) as Figure 4-28 is displayed. Set the RFCH to the control channel of the mobile phone.
4 Operating Procedure Figure 4-28 [Manual Test: Stand-by] Screen (MC-1x) 10 Press the Location Update softkey, and turn the mobile phone on. Wait for it to camp on, and P is shown at the Location Update step. 11 Set the Service Option field to 2, 9, 32 or 55 to start RF test. Set the Service Option field to 1, 3 or 17 to start voice test. 12 Start MS Call or BS Call with the following operation. • Dial an arbitrary number and press the Off Hook button on the mobile phone.
4 Operating Procedure Figure 4-29 [Manual Test: Measuring] Connection Screen (MC-1x) 14 When starting the voice test, the Tester returns voice back to the mobile phone. When starting the RF test, refer the following descriptions. • If the trigger mode is set to Cont (continuous), continuous measurement starts immediately. • If the trigger mode is set to Sing (single), press the Trigger softkey to start single measurement.
4 Operating Procedure Figure 4-30 [Manual Test: Measuring] Result Screen (MC-1x) 16 Press the Meas Max & Min TX Power softkey to measure maximum and minimum TX Power. To measure maximum and minimum TX Power, set the Service Option field to either of 2, 9, 32 and 55.
4 Operating Procedure Figure 4-31 [Manual Test: Measuring] Max & Min TX Power Summary Screen (MC-1x) 17 If you want to measure the Code Domain Power, press the More (1 of 3) and Code Power softkeys to display the Code Domain Power measurement screen. To measure the Code Domain Power, set the Service Option field to either of 2, 9, 32 and 55. • If the trigger mode is set to Cont (continuous), continuous measurement starts immediately.
4 Operating Procedure Figure 4-32 [Manual Test] Code Domain Power Result Screen (MC-1x) • Press the Return softkey to return to the previous screen. 18 Release the call with the following operation. • BS release: Press the Release softkey. • MS release: Press the On Hook button on the mobile phone.
4 Operating Procedure Figure 4-33 [Manual Test: Stand-by] Result Screen (MC-1x) After the release process is completed, the screen will return to the [Stand-by] screen.
4 Operating Procedure Handoff Softer Handoff 1 Follow the process of step 1 to step 13 of Testing a Dual Band Mobile Phone by Manual Test (MC-1x Mode) and set the mobile phone to call connection status. 2 Press the More (1 of 2) and Softer Handoff softkeys to start Softer handoff. The Softer Handoff step is highlighted. When the handoff is completed, P is shown at the Softer Handoff step. 3 Release the call with the following operation. • BS release: Press the Release softkey.
4 Operating Procedure Emergency Call NOTE To test the emergency call function, place the mobile phone and the Tester where the radio signal (electromagnetic wave) from base station of a cell phone operator does not propagate, such as in a shield room, an anechoic chamber, and etc. 1 Follow the process of step 1 to step 11 of Testing a Dual Band Mobile Phone by Manual Test (MC-1x Mode) and set the mobile phone to Stand-by status. 2 Set the Service Option to 1, 3 or 17.
Operating Procedure 4 Figure 4-34 [Manual Test: Measuring] MS Call Emergency Call Screen (MC-1x) N9360A Multi UE Tester CDMA2000 User Manual 4-45
4 Operating Procedure Tests using 1xEV-DO Mode(Option C02) Testing a Dual Band Mobile Phone by Automatic Test (1xEV-DO Mode) This section describes the operation method of the Tester and a dual band (B1:PCS US and B0:Cel US) mobile phone under the test by Automatic Test 1xEV-DO mode. The handoff from the B1:PCS US and B0:Cel US is performed during the test. Set the mobile phone to 1xEV-DO Only mode before measurement. 1 Turn on the Tester and select the cdma2000 system on the [Top Menu] screen.
Operating Procedure 4 3 Set the path loss value. Press the Config, Test Condition and the Loss softkeys from the [Initial] screen to display the [Configuration: Test Condition (Loss)] screen specifying the Loss value. Refer to Entering Loss on the Configuration: Test Condition (Loss) Screen on page 4-22.
4 Operating Procedure Figure 4-37 [Configuration: Test Sequence1] Screen Figure 4-38 [Configuration: Test Sequence 2] Screen 4-48 N9360A Multi UE Tester CDMA2000 User Manual
4 Operating Procedure 5 Set CDMA2000 1xEV-DO in Radio System 1 and 2, respectively, and set other fields as shown in Figure 4-37 and Figure 4-38. 6 Set Run at test item field which you want to execute in the test flow. 7 Set Run at measurement item cell which you want to measure in the measurement item table. 8 Press the Return softkey and then the Test Condition softkey to display the [Configuration: Test Condition] Screen as Figure 4-39 to set the test condition.
4 Operating Procedure Figure 4-40 [Configuration: Test Condition (Limit)] Screen (1xEV-DO) 11 Set appropriate test limits in the cells of the test item table in the upper right side of Figure 4-40. 12 Repeat step 8 to step 11 to set the test condition for Cel US after replacing B1:PCS US with B0:Cel US in Band field. 13 Press the Return softkey three times and then the Automatic Test softkey to start Automatic Test. The [Automatic Test: Stand-by] screen as Figure 4-41 is displayed.
4 Operating Procedure Figure 4-41 [Automatic Test: Stand-by] Value Screen 14 Press the Start softkey to start a test. A screen status changes from Stand-by to Measuring. 15 Turn the mobile phone on. Wait for the mobile phone to camp on, and P is shown at the UATI Assignment step. 16 At the BS Call step, , the mobile phone automatically responds to the call from the Tester. When connected, P is shown at the BS Call step.
4 Operating Procedure Figure 4-42 [Automatic Test: Stand-by] Result Screen 20 If a printer is available, print the test results. Press the More (1 of 2) softkey, and then the Print Screen softkey to print a screen hardcopy. 21 Press the More (2 of 2) softkey to return to the previous softkey menu. 22 If you want to repeat the same test again, press the Start softkey.
4 Operating Procedure Testing a Dual Band Mobile Phone by Manual Test (1xEV-DO Mode) This section describes the operation method of the Tester and a dual band (PCS US and Cel US) mobile phone under the test by the Manual Test 1xEV-DO mode. Set the mobile phone to 1xEV-DO Only mode before measurement. 1 Turn on the Tester and select the cdma2000 system on the [Top Menu] screen. Refer to Selection of System on page 4-14 for selecting a system.
4 Operating Procedure [Configuration: Test Condition (Loss)] screen specifying the Loss value. Refer to Entering Loss on the Configuration: Test Condition (Loss) Screen on page 4-22. Figure 4-44 [Configuration: Test Condition (Loss)] Screen 4 Press the Return softkey to display the [Configuration: Test Condition] screen for required setting in Manual Test 1xEV-DO mode.
4 Operating Procedure Figure 4-45 [Configuration: Test Condition] Screen 5 Select 1xEV-DO at the CDMA Mode field by using the CURSOR CONTROL knob. This value might be set to 1xEV-DO, if the operation of step 2 is preceded. 6 Press the Limit softkey to display the [Configuration: Test Condition (Limit)] Screen (1xEV-DO) as Figure 2.46.
4 Operating Procedure Figure 4-46 [Configuration: Test Condition (Limit)] Screen (1xEV-DO) 7 Set appropriate test limits in the cells of the test item table in the upper right side of Figure 4-46. 8 Press the Return softkey three times and then the Manual Test softkey to start Manual Test. The [Manual Test: Stand-by] Screen (1xEV-DO) as Figure 4-47 is displayed. Set the RFCH to the control channel of the mobile phone.
4 Operating Procedure Figure 4-47 [Manual Test: Stand-by] Screen (1xEV-DO) 9 Press the UATI Assign softkey, and turn the mobile phone on. Wait for the mobile phone to camp on. P is shown at the UATI Assignment step, and Session Opened is highlighted.
4 Operating Procedure Figure 4-48 [Manual Test: Measuring] UATI Assignment Screen (1xEV-DO) 10 Press the BS Call softkey. The mobile phone replies automatically. After BS call starts, the screen as shown in Figure 4-49 is displayed. P is shown at the BS Call step as the test result of BS Call, and Connection is highlighted.
4 Operating Procedure Figure 4-49 [Manual Test: Measuring] BS Screen (1xEV-DO) 11 When starting the RF Test, refer the following descriptions. • If the trigger mode is set to Cont (continuous), continuous measurement starts immediately. • If the trigger mode is set to Sing (single), press Trigger softkey to start single measurement. 12 After the measurement is completed, a [Measuring] summary screen containing test results is displayed.
4 Operating Procedure Figure 4-50 [Manual Test: Measuring] Result Screen (1xEV-DO) 13 Press the Meas Max & Min TX Power softkey to measure Max & Min TX Power.
4 Operating Procedure Figure 4-51 [Manual Test: Measuring] Max & Min TX Power Screen (1xEV-DO) 14 When measuring Code Domain Power, press the More (1 of 3) and Code Power softkeys to display the Code Domain Power measurement screen. Perform Code Domain Power measurement in accordance with the trigger mode setting described below. • If the trigger mode is set to Cont (continuous), continuous measurement starts immediately.
4 Operating Procedure Figure 4-52 [Manual Test] Code Domain Power Result Screen (1xEV-DO) • Press the Return softkey to return to the previous screen. 15 Release the call with the following operation. • Press the Connection Close, More (1 of 3) and Session Close softkeys. After the release process is completed, the screen is returned to the [Stand-by] screen.
Operating Procedure 4 Figure 4-53 [Manual Test: Stand-by] Result Screen (1xEV-DO) N9360A Multi UE Tester CDMA2000 User Manual 4-63
4 Operating Procedure Handoff Softer Handoff 1 Follow the process of step 1 to step 10 of Testing a Dual Band Mobile Phone by Manual Test (1xEV-DO Mode) and set the mobile phone to call connection status. 2 Press More (1 of 3) and Softer Handoff softkeys to start Softer handoff. The Softer Handoff step is highlighted. When the handoff is completed, P is shown at the Softer Handoff step. 3 Release the call with the following operation.
4 Operating Procedure Testing a Mobile Phone by TX Analyzer This section describes the operation method of the Tester for a test by the TX Analyzer. 1 Turn on the Tester and select the cdma2000 system on the [Top Menu] screen. Refer to Selection of System on page 4-14 for selecting a system. 2 The [Initial] screen as Figure 4-54 is displayed after completion of initialization and self-test routine of the Tester. Figure 4-54 [Initial] Screen 3 Set the path loss values.
4 Operating Procedure Figure 4-55 [Configuration: Test Condition (Loss)] Screen 4 Press the Return softkey to display the [Configuration: Test Condition] screen to set the test condition.
Operating Procedure 4 Figure 4-56 [Configuration: Test Condition] Screen 5 Set the input fields of the test parameter as shown in Figure 4-56. 6 Press the Limit softkey to display the [Configuration: Test Condition (Limit)] screen as Figure 4-57.
4 Operating Procedure Figure 4-57 [Configuration: Test Condition (Limit)] Screen 7 Enter appropriate test limits in the cells of the test item table on the [Configuration: Test Condition] screen. 8 Press the Return softkey three times and the TX Analyzer softkey. The [TX Analyzer: Stand-by] screen as Figure 4-58 is displayed.
4 Operating Procedure Figure 4-58 [TX Analyzer: Stand-by] Screen 9 Set the mobile phone to transmit the bursted RF signal. 10 Start a test with the following operation. • When the trigger mode is Sing, single measurement starts after the Trigger softkey is pressed. • To change the trigger mode to Cont in order to start continuous measurement, press the Trigger Sing/Cont softkey. When the trigger mode is Cont, continuous measurement starts as soon as the [TX Analyzer: Stand-by] screen is displayed.
4 Operating Procedure Figure 4-59 [TX Analyzer: Stand-by] Result Screen 4-70 N9360A Multi UE Tester CDMA2000 User Manual
4 Operating Procedure Testing a Mobile Phone by Signal Generator This section describes the operation method of the Tester for a test by the Signal Generator. 1 Turn on the Tester and select the cdma2000 system on the [Top Menu] screen. Refer to Selection of System on page 4-14 for selecting a system. 2 The [Initial] screen as Figure 4-60 is displayed after completion of initialization and self-test routine of the Tester. Figure 4-60 [Initial] Screen 3 Set the path loss values.
4 Operating Procedure Figure 4-61 [Configuration: Test Condition (Loss)] Screen 4 Press the Return three times and then press the Signal Generator softkey on the [Initial] screen. The [Signal Generator] screen as Figure 4-62 is displayed.
Operating Procedure 4 5 Set the input fields. 6 Press the RF Output On/Off softkey to change On/Off state from Off to On for transmitting RF signal to the mobile phone. 7 Press the RF Output On/Off softkey again to change On/Off state from On to Off for termination of the test.
4 Operating Procedure Ending a Test CAUTION In the Tester, the HDD is used for storage. Do not turn off the Line switch on the rear panel of the Tester while the LINE LED on the front panel of the Tester is lit in green. Otherwise, Tester failure may occur. Disconnecting the Mobile Phone Disconnect the mobile phone from the connection cable or the antenna coupler. Turning off the Tester Turn off the Tester with the following procedure.
Agilent N9360A Multi UE Tester CDMA2000 User Manual 5 Description of Screens Screen Structure 5-2 Top Menu Screen 5-3 Configuration Screen 5-6 Firmware Update Screen 5-12 Update Flash Screen 5-16 Network Setting 5-19 Initial Screen 5-23 Return to Menu Screen 5-26 PRESET Mode Selection Screen 5-27 Automatic Test (MC-1x Mode) 5-29 Measuring Screen 5-36 Manual Test (MC-1x Mode) 5-51 Automatic Test (1xEV-DO Mode) 5-76 Measuring Screen 5-83 Manual Test (1xEV-DO Mode) 5-94 TX Analyzer 5-114 Signal Generator 5-13
5 Description of Screens Screen Structure The following Figure 5-1 shows the screen structure that consists of screens for each mode. Each box represents a screen in a different mode or test conditions.
Description of Screens 5 Top Menu Screen After power on, the [Top Menu] screen as Figure 5- 2 is displayed. This screen is used to select a system or to display the [Configuration] screen. Options for the Tester system are GSM, W- CDMA, and/or cdma2000. Figure 5-2 Top Menu Structure Menu GSM NOTE WCDMA cdma2000 Configuration Firmware Update This N9360A Multi UE Tester CDMA2000 USer Manual provides information for the cdma2000 system only.
5 Description of Screens Figure 5-3 [Top Menu] Screen Softkey Menu Field Softkey Menu 1 • GSM: Selects the GSM system. After the system is selected, the Tester is automatically rebooted, and then displays the [Initial] screen for GSM system. This softkey is activated when the GSM system is installed in the Tester. • WCDMA: Selects the W-CDMA system. After the system is selected, the Tester is automatically rebooted, and then displays the [Initial] screen for W-CDMA system.
Description of Screens 5 Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves an image file of the screen into a USB memory device depending on the setting of the Printer field on the [Configuration] screen. • Reboot: Aborts the current system and returns the [Top Menu] screen after reboots the Tester. • More (2 of 2): Displays the Softkey Menu 1.
5 Description of Screens Configuration Screen When the Config softkey is pressed on the [Top Menu] screen, the [Configuration] screen as Figure 5-4 is displayed. If the option E02 is not installed, the screen is as shown in Figure 5-5; if the option E01 is not installed, the screen is as shown in Figure 5-6. The following various conditions are set on this screen.
5 Description of Screens Softkey Menu Field Softkey Menu • Print Screen: Prints a hardcopy of the screen or saves it in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • FW Update: Displays the [Firmware Update] screen. • Network Setting: Displays the [Network Setting] screen. • Option Install: Used to install option functions to display in E01 or E02. • Option Backup: Backs up the installed option functions.
5 Description of Screens Screen Field Set the input items required to use the Tester, referring to the description shown in Table 5-1. Table 5-1 Input Items on the [Configuration] Screen Input Field Reference Description Selects the reference signal from Internal and External. • Internal: Use the internal 10 MHz reference signal. • External: Use the external 10 MHz reference signal. The 10 MHz reference signal must be supplied to the 10MHz Reference IN connector on the rear panel.
5 Description of Screens Table 5-1 Input Items on the [Configuration] Screen Input Field Description Beeper Sets the beep sound. Selects On or Off. • On: Beeps for each step of operation. • Off: Beeps only for noticing some errors and warnings. AutoBoot Selects the system for automatic boot when a certain time (time-out period) has passed since the [Top Menu] screen was displayed.
5 Description of Screens Option Installation/Backup On the [Configuration] screen, you can install/back up option functions such as C01, C02, W00, and G00. NOTE To install options, the option key suitable for required option is necessary. For further information, contact the Agilent Sales Department or an authorized distributor. Option Installation Install option functions to the Tester. There are two way to install it. One is using a USB memory device. The other is not using a USB memory device.
5 Description of Screens 4 The option number is added in the Option field in the information field. Option Backup Before Back up option information, prepare the USB memory device containing a suitable Option Key. 1 Press the Config softkey on the [Top menu] screen to display [Configuration] screen. 2 Insert USB memory device containing the Option Key into the USB connector on the front panel of the Tester. 3 Press the Option Backup softkey.
5 Description of Screens Firmware Update Screen The Tester provides three methods to update the firmware: USB (installs the firmware files placed in the USB memory device which is connected to the Tester), HDD (installs the firmware files placed in the Tester's internal HDD), SERVER (installs the firmware files placed on the external server). You can select one method by setting the Update Type to either of USB, HDD, and SERVER.
5 Description of Screens • Revision: The current firmware revision in the Tester and the revision of the firmware files placed at the file storage area specified by the selected Update Type. • ?.??.??: Indicates that there is no firmware files at the file storage area specified by the selected Update Type. • -.--.--: or "*.**.**" Indicates that the firmware is not installed in the Tester. • (complete): Indicates that the firmware is updated successfully. It is displayed in the Update Version display area.
5 Description of Screens • Press this softkey to update the Top Menu functions after placing the firmware files of the Top Menu functions at the file storage area specified by the selected Update Type. Restart the Tester after updating the Top Menu functions. • Update Func Tester: Updates the Function Tester functions. • Press this softkey to update the Function Tester functions after placing the firmware files of the Function Test functions at the file storage area specified by the selected Update Type.
5 Description of Screens Message Field The following messages are displayed depending on the state: • Press [Update xxxx] to update. (This message is displayed if any firmware exists in the USB memory.) • Press [Update System] to update. ("xxxx") (This message is displayed when the available firmware files exist at the file storage area specified by the selected Update Type.) • System condition error. Please execute system update. • USB memory is not inserted. • USB memory is accessed now.
5 Description of Screens Update Flash Screen The Tester provides three methods to update the firmware: USB (installs the firmware files placed in the USB memory device which is connected to the Tester), HDD (installs the firmware files placed in the Tester's internal HDD), SERVER (installs the firmware files placed on the external server). You can select one method by setting the Update Type to either of USB, HDD, and SERVER.
5 Description of Screens • Revision: Displays the current firmware revision in the Tester and the revision of the firmware files placed at the file storage area specified by the selected Update Type. • "?.??.??": Indicates that there is no firmware files at the file storage area specified by the selected Update Type. • "-.--.--" or"*.**.**: Indicates that the firmware is not installed in the Tester. • "(complete)": Indicates that the firmware is updated successfully.
5 Description of Screens • Update 1xEV-DO: Updates the 1xEV-DO functions. • Press this softkey to update the 1xEV-DO functions after placing the firmware files of the 1xEV-DO functions at the file storage area specified by the selected Update Type. • More (1 of 2): Displays the Softkey Menu 2. • Return: Return to the [Firmware Updater] screen.
5 Description of Screens Network Setting On the [Network Setting] screen, you can configure the network settings. Press the Network Setting softkey on the [Configuration] screen, the [Network Setting] screen as shown in Figure 5-9 is displayed. This screen allows you to configure various settings for the following.
5 Description of Screens • Apply Address: Applies the changes of IP Addr, Mask, Default Gateway, Host/Net, Gateway, and CIDR to the Tester. This softkey is not activated when the [Network Setting] screen is displayed and no setting is changed. This softkey is activated when any input field is changed. After applying the settings, this softkey is inactivated again. • Cancel: Returns to the [Configuration] screen. Values changed before the Apply Address softkey is pressed revert to the former values.
5 Description of Screens Table 5-2 Input Items on the [Network Setting] Screen (continued) Input Field Description Default Gateway Sets active or inactive of the Default Gateway setting and sets Default Gateway address. The allowable settings are as follows: • None: Default Gateway setting is inactivated. • ACT: Default Gateway setting is activated. • If you select None, the field to set an address will be grayed out and inactivated. • 1.0.0.1 to 223.255.255.255.255 (From 192.168.1.1 to 192.168. 1.
5 Description of Screens Table 5-2 Input Items on the [Network Setting] Screen (continued) Input Field Description Gateway Sets the gateway addresses for gateway setting from 1 through 5. Allowable settings are as follows: • 1.0.0.1 to 223.255.255.255 (From 192.168.1.1 to 192.168.1.255 are unavailable to setting.) • The IP address setting supports Class A through C. • The Tester does not support Class D (multicast address) and Class E (reserved address).
5 Description of Screens Initial Screen When the CDMA2000 softkey on the [Top Menu] screen is pressed, the [Initial] screen as Figure 5-10 is displayed. This screen is used to select one of the function modes or to return to the [Top Menu] screen. To return to the [Initial] screen from any function mode, press the Return softkey (multiple times if necessary). Figure 5-10 [Initial] Screen Softkey Menu Field Softkey Menu • Automatic Test: Displays the [Auto Test: Stand-by] screen.
5 Description of Screens • CDMA Mode>>: Selects the CDMA mode. Displays the Sub Softkey Menu 3 to select the mode from MC-1x or 1xEV-DO. • More (1 of 2): Displays the Softkey Menu 2. • Config: Displays the [Configuration] screen. Refer to Configuration on page 5-137. Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or stores the screen image in the USB memory, according to the Printer field on the [Configuration] screen.
Description of Screens 5 Message Field The following message is displayed in the message field: Select a Test Mode or Configuration.
5 Description of Screens Return to Menu Screen When the Return to Menu softkey is pressed on the [Initial] screen, the following screen as Figure 5-11 is displayed. Figure 5-11 [Return to Menu] Screen Softkey Menu Field Softkey Menu • OK: Returns to the [Top Menu] screen • Cancel: Returns to the [Initial] screen. Screen Field The following message is displayed in the screen field: To reboot the instrument is necessary for returning to the menu.
5 Description of Screens PRESET Mode Selection Screen When the PRESET button on the front panel of the Tester is pressed before selecting the system, the [PRESET Mode Selection] Screen (Top Menu) as Figure 5-12 is displayed. Figure 5-12 [PRESET Mode Selection] Screen (Menu) Press the PRESET key after selecting cdma2000 system, the [PRESET Mode Selection] Screen (cdma2000) as Figure 5-13 appears.
5 Description of Screens Figure 5-13 [PRESET Mode Selection] Screen (cdma2000) Softkey Menu Field Softkey Menu • Factory Default: All the parameters of the Tester other than parameters related to external control revert to the default. They revert to the factory default. After selecting this softkey, the [Top Menu] screen or the [Initial] screen for the cdma2000 appear. This influences the parameters of GSM, W-CDMA, and cdma2000.
5 Description of Screens Automatic Test (MC-1x Mode) Overview Feature of Automatic Test • Pass or Fail test results in the test flow and measurement items are automatically obtained. • This function executes RF test changing frequencies on up to six channels automatically. Combining Sequence1 and Sequence2 enables measurement up to 12 channels in one test.
5 Description of Screens Automatic RF Test Table 5-4 shows the measurement items of the RF test. For the judgment criteria of measurement items, refer to Table 5-49. Table 5-4 Measurement Items for Automatic Test (MC-1x) Measurement Item Description Access Probe Power Measures and displays the access probe power when receiving an access probe before connection.
Description of Screens 5 Stand-by Screen When the Automatic Test softkey is pressed on the [Initial] screen, the [Auto Test: Stand-by] simplified screen is displayed. Then, any of the [Auto Test: Stand-by] simplified screen (Figure 5-14), the [Auto Test: Stand-by] detailed screen (Figure 5-15), or the [Auto Test: Stand-by] value screen (Figure 5-16) is displayed according to the setting of the Simple, the Detail and the Value softkey.
5 Description of Screens Figure 5-15 [Auto Test: Stand-by] Detailed Screen (MC-1x) Figure 5-16 [Auto Test: Stand-by] Value Screen (MC-1x) Softkey Menu Field Softkey Menu 1 • Start: Starts testing the mobile phone by Automatic Test. • Previous Screen: Changes the screen to the previous sequence one. This softkey is inactivated when the screen of the sequence 1 is displayed.
5 Description of Screens • Next Screen: Changes the screen to the next sequence one. This softkey is inactivated when the sequence 2 is set to Off or the screen of Sequence 2 is displayed. • Screen>>: Displays the softkey menu 3 containing the softkeys to select the display mode. • More (1 of 2): Displays the softkey menu 2. • Return: Returns to the [Initial] screen.
5 Description of Screens The input fields of parameters except procedure are protected if the Panel Key is set to Lock on the [Configuration] screen. Set the input fields in the screen field according to the following description of Table 5-18 to execute a new test. The file name for the file currently in use will be displayed in this item. Table 5-5 Input Items on the [Auto Test: Stand-by] Screen (MC-1x) Input Field Description Procedure Specify a parameter file to be used for the test.
5 Description of Screens Table 5-6 Items that provide information from the Mobile Phone and the Tester on the [Automatic Test: Stand-by] Screen (MC-1x) Item Information Description 3GPP-SYS Displays the value of the 3GPP System that is set on the [Configuration: Test Sequence] and the [Configuration: Test Condition] screens. SIG-PTN Displays the value of the Signaling Pattern that is set on the [Configuration: Test Condition] screen.
5 Description of Screens Measuring Screen When the Start softkey is pressed on the [Auto Test: Stand-by] screen, a [Auto Test: Measuring] Simplified Display Screen as shown in Figure 5-17 is displayed and then a test starts. The status of sequences is shown on the upper left corner of the screen. The sequence under test execution is underlined. One of the test flow steps is highlighted to show which step is currently being tested.
Description of Screens 5 Figure 5-18 [Auto Test: Measuring] Detailed Screen (MC-1x) Figure 5-19 [Auto Test: Measuring] Value Screen (MC-1x) Softkey Menu Field Softkey Menu 1 • Screen>>: Displays the softkey menu 2 containing the softkeys to select the display mode.
5 Description of Screens • Abort: Aborts the measurement and returns to the [Stand-by] screen. Softkey Menu 2 • Simple: Displays a Pass/Fail result of whole measurement in the center of the measurement result field in zoom. • Detail: Displays a Pass/Fail result at each item cell in the measurement result field. • Value: Displays a measurement value at each item cell in the measurement result field. • Cancel: Cancels changing the display mode and returns to the softkey menu 1.
Description of Screens 5 Measuring Talk Screen During Talk test execution, a [Measuring] Talk screen is displayed. This test is to determine whether the test is passed or failed by checking the quality of the looped back voice.
5 Description of Screens Figure 5-21 [Automatic Test: Measuring] Talk Detailed Screen (MC-1x) Figure 5-22 [Automatic Test: Measuring] Talk Value Screen (MC-1x) Softkey Menu Field Softkey Menu 1 • Pass: Press this softkey if the loop back voice is of good quality. Then this softkey disappears and P is shown next to the Talk step.
5 Description of Screens • Fail: Press this softkey if the loop back voice is of poor quality or the voice does not loop back. Then this softkey disappears and F is shown next to the Talk step. • Screen>>: Displays the softkey menu 2 containing the softkeys to select the display mode. • Abort: Aborts the test and returns to the [Stand-by] screen. Softkey Menu 2 • Simple: Displays a Pass/Fail result of whole measurement in the middle of the measurement result field in zoom.
5 Description of Screens Aborted screen When the Abort softkey is pressed, the measurement is aborted. Any of the [Automatic Test: Stand-by] Aborted Simplified Screen (MC-1x), the [Automatic Test: Stand-by] Aborted Detailed Screen, or the [Automatic Test: Measuring] Aborted Value Screen is displayed, depending on the previous setting of the Simple, the Detail or the Value softkey. Figure 5-23 is a screen with the Simple softkey setting.
5 Description of Screens Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • More (2 of 2): Returns to the softkey menu 1. Softkey Menu 3 • Simple: Displays a Pass/Fail result of whole measurement in the middle of the measurement result field in zoom. • Detail: Displays a Pass/Fail result at each item cell in the measurement result field.
5 Description of Screens Sequence 2 Screen When Sequence 2 is set on the [Configuration: Test Sequence] screen in the Configuration mode, Sequence 2 start after completion in Sequence 1. When Sequence 2 is started, the [Automatic Test: Measuring] Sequence 2 Screen (MC-1x) as Figure 5-24 is displayed. (Figure 5-24 shows a screen changing to Sequence 2, when Sequence 1 is set to cdma2000 MC-1x, Sequence 2 is set to cdma2000 MC-1x, and System Handoff, the 11th of Sequence 1, is set to BS Release (Run).
5 Description of Screens Softkey Menu 2 • Simple: Displays a Pass/Fail result of whole measurement in the middle of the measurement result field in zoom. • Detail: Displays a Pass/Fail result at each item cell in the measurement result field. • Value: Displays a measurement value at each item cell in the measurement result field. • Cancel: Cancels changing the display mode and returns to the softkey menu 1.
5 Description of Screens Measurement Result Display Screen When all the pre-configured tests are finished, the measurement results are displayed in the stand-by screens.
Description of Screens 5 Figure 5-25 [Automatic Test: Stand-by] Result Simplified Screen (MC-1x) for Measurement Results Figure 5-26 [Automatic Test: Stand-by] Result Detailed Screen (MC-1x) for Measurement Results N9360A Multi UE Tester CDMA2000 User Manual 5-47
5 Description of Screens Figure 5-27 [Automatic Test: Stand-by] Result Value Screen (MC-1x) for Measurement Results Softkey Menu Field Softkey Menu 1 • Start: Starts the testing the mobile phone by the Automatic Test. • Previous Screen: Displays the previous sequence screen. This softkey is inactivated when the screen of the sequence 1 is displayed. • Next Screen: Displays the next sequence screen. This softkey is inactivated when the sequence 2 is set to Off or the screen of Sequence 2 is displayed.
5 Description of Screens Softkey Menu 3 • Simple: Displays a Pass/Fail result of whole measurement in the middle of the measurement result field in zoom. • Detail: Displays a Pass/Fail result at each item cell in the measurement result field. • Value: Displays a measurement value at each item cell in the measurement result field. • Cancel: Cancels changing the display mode and returns to the softkey menu 1.
5 Description of Screens Table 5-9 Items that provide information from the Mobile Phone and the Tester on the [Automatic Test: Stand-by] Result Screen (MC-1x) Item Information Description IMSI Displays the International Mobile Subscriber Identity sent from the mobile phone. ESN Displays the international mobile station identity that is sent from the mobile phone. Caller ID Displays dialer number sent from the Tester at BS Call step. Dialed No.
5 Description of Screens Manual Test (MC-1x Mode) Overview Feature of Manual Test • All test items are executed while the mobile phone and the Tester are connected by call control protocol. • Measurement in the Talk/RF test step in the test flow is executed in a real-time. • The following systems can be selected directly from the Manual Test screen. Required options are in parentheses.
5 Description of Screens RF Test with Manual Test Table 5-10 describes measurement items of RF test. The limit for measurement items can be set on the [Configuration: Test Condition] screen. Refer to Configuration: Test Condition Screen on page 5-158. Table 5-10 Manual Test: Measurement Items (MC-1x) NOTE Input Field Description TX Power Measures the transmission power of the mobile phone during connection. The measurement range is from -60 to +36 dBm.
5 Description of Screens Stand-by Screen When the Manual Test softkey is pressed on the [Initial] screen, the [Manual Test: Stand-by] Screen (MC-1x) as Figure 5-28 is displayed. Figure 5-28 [Manual Test: Stand-by] Screen (MC-1x) Softkey Menu Field Softkey Menu 1 • Location Update: Executes the Location Update process in the Tester.
5 Description of Screens •The measurement is terminatedends when the trigger mode is changed from Cont to Sing. • Trigger: Starts measurement during the Connection status. This softkey is inactivated in the stand-by status but activated in the connection status. • More (1 of 3): Displays the softkey menu 2. • Return: Returns to the [Initial] screen.
5 Description of Screens • W-CDMA: Changes the system to W-CDMA. Installation for W00 Option is required. • HSDPA: Changes the system to HSDPA. Installation for G06 Option is required. • CDMA2000>>: Displays the Softkey Menu 5 to select the cdma2000 system. • Cancel: Cancels selecting a system and returns to the Softkey Menu 2. Softkey Menu 5 • MC-1x: This softkey is unavailable. • 1xEV-DO: Changes the system to the 1xEV-DO mode on the CDMA Mode. The C00, C01, and C02 options are required.
5 Description of Screens Table 5-11 Input Items in [Manual Test: Stand-by] Screen (MC-1x) Input Field Description RFCH * Specifies the band and channel number. This parameter can be changed when in the stand-by or Connection status.
5 Description of Screens Table 5-11 Input Items in [Manual Test: Stand-by] Screen (MC-1x) Input Field Description PWR CNTL* Specifies the power control bit to control TX Power of the mobile phone.
5 Description of Screens Table 5-11 Input Items in [Manual Test: Stand-by] Screen (MC-1x) Input Field Description SCH Level Sets code level of the forward supplemental Channel. This item is displayed only when the Radio Config is set to F3R3, F4R3, or F5R4 with the Service Option of 32. The allowable range is as follows: –20.00 to –2.50 dB (in 0.25 dB steps) * The changing magnification softkey is available. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on page 4-13.
5 Description of Screens The RF On indicator is displayed at the screen lower left corner only when the RF signal from the Tester is present at the RF IN/OUT connector. CDT Off is displayed on the lower left of the display only when the Call Drop Timer is set to Off. Message Field The following message is displayed in the message field on the [Stand-by] screen: Press {Loc Update}, {BS Call} or dial and call from the mobile. The word surrounded by {} in the message field denotes the softkey.
5 Description of Screens Figure 5-29 [Manual Test: Measuring] MS Call Hold Screen (MC-1x) The following test result is displayed on the test result field of the MS Call step. • P: Displayed on blue background when a proper call setup is executed and MS Call is passed. • F: Displayed on red background when MS Call is failed. When one of above procedure is performed, the screen changes from [Stand-by] screen to [Measuring] screen and a test starts.
5 Description of Screens Connection Screen When call connection between the mobile phone and the Tester is succeeded, a [Measuring] connection screen as Figure 5-30 or Figure 5-31 is displayed. If the Service Option field is set to 2, 9, 32 or 55, and the trigger mode is set to Cont, continuous measurement of RF test starts when the [Measuring] connection screen is displayed.
5 Description of Screens Figure 5-31 [Manual Test: Measuring] MS Call Connection Screen (MC-1x) Softkey Menu Field Softkey Menu 1 • Release: Starts the BS release step. • Meas Max & Min TX Power: Starts measuring the maximum and minimum transmission powers. This softkey is not available when the Service Option is set to 1, 3, 17, or 32768. • Clear Status: Clears Pass/Fail results of the protocol test.
5 Description of Screens • More (1 of 3): Displays the Softkey Menu 2 Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • Softer Handoff: Starts Softer handoff. • Code Power: Displays the [Code Domain Power] measurement screen. • More (2 of 3): Displays the Softkey Menu 3. Softkey Menu 3 • Debug Data > USB: This softkey is unavailable.
5 Description of Screens Table 5-13 Input Items on [Manual Test] Connection Screen (MC-1x) Input Field Description RFCH * Specifies the band and channel number. This parameter can be changed when the stand-by or Connection status.
5 Description of Screens Table 5-14 Mobile Phone Information on [Manual Test: Measuring] Screen (MC-1x) Item Information Description IMSI Displays the International Mobile Subscriber Identity sent from the mobile phone, with Max. 15 digits. ESN Displays the international mobile station identity sent from the mobile phone, with Max. 8 digits. This number cannot be displayed when the state is Stand-by. Caller ID Displays the dialer number sent from the Tester at BS Call step.
5 Description of Screens Message Field The following message is displayed in the message field on the Connection screens: Press the desired softkey. Code Domain Power Measurement Screen Code Domain Power Measurement simultaneously measures all test items regardless of whether the result is pass or fail.
5 Description of Screens Softkey Menu Field Softkey Menu 1 • Trigger Sing/Cont: Measures the Code Domain Power. Select Sing (single measurement) or Cont (continuous measurement) as the trigger mode. This item is unavailable on this screen. • Selecting Cont as the trigger mode will immediately start the continuous measurement. • Changing the trigger mode from Cont to Sing will end the measurement. • Trigger: Measures the Code Domain Power.
5 Description of Screens Table 5-15 Input Items on [Manual Test: Measuring] Code Domain Power Measurement Screen (MC-1x) Input Field Description RFCH * Specify the band and channel number. Available in the stand-by or Connection status.
5 Description of Screens Table 5-16 Mobile Phone Information on [Manual Test: Measuring] Code Domain Power Screen (MC-1x) Item Information Description Caller ID Display the Caller ID notification setting. When the Caller ID notification is set to ON, the Tester notifies the Caller ID to the mobile phone at BS Call step. Procedure Displays the file name of the parameter file in current use. Radio System Displays CDMA2000 on the lower left of the screen.
5 Description of Screens Measuring Screen In connection state, RF test can be executed to measure the mobile phone performance before the call is released. When the Service Option is set to 1, 3, 17, or 32768 (voice call is selected), the RF test cannot be executed..
Description of Screens 5 Figure 5-34 [Manual Test: Measuring] MS Call Screen (MC-1x) Softkey Menu Field Softkey Menu • Trigger Sing/Cont: Starts the RF test. Selects the trigger mode from Sing (single) and Cont (continuous). •Selecting Cont as the trigger mode will immediately start the continuous measurement. •Changing the trigger mode from Cont to Sing will terminate the measurement.
5 Description of Screens Result Screen When the measurement is completed, a [Measuring] measurement result display screen showing the measurement results is displayed. • To end the measurement by BS release, press the Release softkey to disconnect from the Tester. • To end the measurement by MS release, press the On Hook button on the mobile phone or the Release softkey to disconnect from the mobile phone.
5 Description of Screens Figure 5-36 [Manual Test: Stand-by] MS Call Result Screen (MC-1x) Softkey Menu Field Softkey Menu 1 • Location Update: Executes the Location Update process in the Tester. When the softkey is pressed, the NID and the SID on the broadcast information are changed to the Rgstr NID and the Rgstr SID setting on the [Configuration: Test Condition] screen. • BS Call: Executes BS Call. • Clear Status: Clears Pass/Fail results at signaling steps in the test flow.
5 Description of Screens • Trigger: Starts measurement in the Connection status. This softkey is inactivated in the stand-by status but activated in the Connection status. • More (1 of 3): Displays the Softkey Menu 2. • Return: Returns to the [Initial] screen. Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen.
5 Description of Screens • HSDPA: Changes the system to HSDPA. The W00 and W06 options are required. • CDMA2000>>: Displays the Softkey Menu 5 to select the cdma2000 system. • Cancel: Cancels selecting a system and returns to the Softkey Menu 2. Softkey Menu 5 • MC-1x: This softkey is unavailable. • 1xEV-DO: Changes the system to the 1xEV-DO mode on the CDMA Mode. The C00, C01 and C02 options are required. • Cancel: Cancels selecting the display mode and returns to the Softkey Menu 2.
5 Description of Screens Automatic Test (1xEV-DO Mode) This section explains how to test a mobile phone by Automatic Test: 1xEV-D0 mode. NOTE Install the C02 option to use the test function in the 1xEV-D0 mode. Overview Feature of Automatic Test • Pass or Fail test results in the test flow and measurement items are automatically obtained. • This function executes RF test changing frequencies up to six channels automatically.
5 Description of Screens • Sequence: Up to two test sequences can be set on the [Configuration: Test Sequence] screen. RF Test in Automatic Test Table 5-17 shows the measurement items of the RF test. For the judgment criteria of measurement items, refer to Configuration: Test Condition Screen. Table 5-17 explains the measurement items for Automatic Test. The result (pass or fail) of each measurement item is set on the [Configuration: Test Condition] screen.
5 Description of Screens NOTE A changing magnification softkey to input numerical values will be enabled. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on page 4-13. Default settings for the Tester at the time when the power is turned on represent the settings that were set last time the power was turned off.
Description of Screens 5 Stand-by Screen When the Automatic Test is pressed on the [Initial] screen, the [Auto Test: Stand-by] Simplified Screen (1xEV-DO) is displayed as shown in Figure 5-37. Then, any of the [Automatic Test: Stand-by] Simplified Screen (1xEV-DO) (Figure 5-37), the [Automatic Test: Stand-by] Detailed Screen (1xEV-DO) (Figure 5-38), or the [Automatic Test: Stand-by] Value Screen (Figure 5-39) is displayed according to the setting of the Simple, the Detail and the Value softkey.
5 Description of Screens Figure 5-38 [Automatic Test: Stand-by] Detailed Screen (1xEV-DO) Figure 5-39 [Automatic Test: Stand-by] Value Screen (1xEV-DO) Softkey Menu Field Softkey Menu 1 • Start: Starts testing the mobile phone by the Automatic Test. • Previous Screen: Displays the previous sequence screen. This softkey is inactive when the Sequence 1 screen is displayed.
5 Description of Screens • Next Screen: Displays the next sequence screen. This softkey is inactive when Sequence 2 is set to Off or the Sequence 2 screen is displayed. • Screen>>: Displays the Softkey Menu 3 containing the softkeys to select the display mode. • More (1 of 2): Displays the Softkey Menu 2. • Return: Returns to the [Initial] screen.
5 Description of Screens Table 5-18 Input Items on [Automatic Test: Stand-by] Screen (1xEV-DO) Input Field Description Procedure Specify a parameter file to be used for the test. This item displays the file name for the parameter file that is currently in use. It is also possible to select a parameter file from existing parameter files and specify it as the file to be used for the test. RFCH * Specify the band and channel number. This parameter can be changed when the stand-by status.
5 Description of Screens Measuring Screen When the Start softkey is pressed on the [Automatic Test: Stand-by] screen, a [Automatic Test: Measuring] screen is displayed and then a test starts. The status of sequences is displayed on the upper left corner of the screen. The sequence under test execution is underlined. One of the test flow steps is highlighted to show which step is currently being tested.
5 Description of Screens Figure 5-41 [Automatic Test: Measuring] Detailed Screen (1xEV-DO) Figure 5-42 [Measuring] Numeric Value Display Screen Softkey Menu Field Softkey Menu 1 • Screen>>: Displays the Softkey Menu 2 containing the softkeys to select the display mode. • Abort: Aborts the measurement and returns to the [Stand-by] screen.
5 Description of Screens Softkey Menu 2 • Simple: Displays a Pass/Fail result of whole measurement in the middle of the measurement result field in zoom. • Detail: Displays a Pass/Fail result at each item cell in the measurement result field. • Value: Displays a measurement value at each item cell in the measurement result field. • Cancel: Cancels changing the display mode and returns to the Softkey Menu 1. Screen Field The information from the mobile phone as Table 5-20 is displayed in the screen field.
5 Description of Screens Aborted screen When the Abort softkey is pressed, the measurement is aborted. Any of the [Stand-by] Simple Display Screen for Abort (Figure 5-43), [Stand-by] Detail Display Screen for Abort, or [Stand-by] Numeric Value Display Screen for Abort depending on the previous setting of the Simple, the Detail or the Value softkey. Figure 5-43 is a screen with the Simple softkey setting.
5 Description of Screens Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • More (2 of 2): Returns to the Softkey Menu 1. Softkey Menu 3 • Simple: Displays a Pass/Fail result of whole measurement in the middle of the measurement result field in zoom. • Detail: Displays a Pass/Fail result at each item cell in the measurement result field.
5 Description of Screens Description Detailed measurement results up to the aborted operation can be obtained. The status of the Tester is returned to Stand-by. The status of the mobile phone is not ensured; therefore, the mobile phone power-on process is required for a new test. Sequence 2 Screen When Sequence 2 is set on the [Configuration: Test Sequence] screen in the Configuration mode, the test for Sequence 2 start after completion of Sequence 1 last test.
5 Description of Screens Softkey Menu 1 • Screen>>: Displays the softkey menu 2 containing the softkeys to select the display mode. • Abort: Aborts the measurement and returns to the [Stand-by] screen. Softkey Menu 2 • Simple: Displays a Pass/Fail result of whole measurement in the middle of the measurement result field in zoom. • Detail: Displays a Pass/Fail result at each item cell in the measurement result field. • Value: Displays a measurement value at each item cell in the measurement result field.
5 Description of Screens • On the result detailed display screen, a Pass or Fail measurement result is shown at each item cell in the measurement result field. • On the result value screen, a measurement value is shown at each item cell in the measurement result field. When some test items and measurement items are set to be skipped on the [Configuration: Test Sequence] screen, each result of test items and measurement items is shown by – or —.
5 Description of Screens Figure 5-46 [Automatic Test: Stand-by]Result Detailed Screen (1xEV-DO) Figure 5-47 [Automatic Test: Stand-by] Result Value Screen (1xEV-DO) Softkey Menu Field Softkey Menu 1 • Start: Starts testing the mobile phone by the Automatic Test. • Previous Screen: Changes the screen to the previous sequence one. This softkey is inactivated when the screen of the sequence 1 is displayed.
5 Description of Screens • Next Screen: Changes the screen to the next sequence one. This softkey is inactivated when the sequence 2 is set to Off or the screen of Sequence 2 is displayed. • Screen>>: Displays the Softkey Menu 3 containing the softkeys to select the display mode. • More (1 of 2): Displays the Softkey Menu 2. • Return: Returns to the [Initial] screen.
5 Description of Screens Table 5-21 Input Items on [Automatic Test: Stand-by] Result Screen (1xEV-DO) Input Field Description RFCH * Specifies the band and channel number. This parameter can be changed when the stand-by status.
5 Description of Screens Manual Test (1xEV-DO Mode) This section explains the standard manual test procedure of a mobile phone in the 1xEV-DO Manual Test mode. NOTE Install the C02 option to use the test function in the 1xEV-D0 mode. Overview Features of Manual Test • All test items are executed while the mobile phone and the Tester are connected by call control protocol. • Measurement in the RF test step in the test flow is executed in a real-time.
5 Description of Screens Manual RF Test Table 5-23 describes measurement items of Manual RF Test. The limit for measurement items can be set on the Configuration: Test Condition Screen on page 5-158. Table 5-23 Standard Test Items in 1xEV-DO Manual Test Measurement Item Test Item Description TX Power Measures the transmission power of the mobile phone during connection. The measurement range is from –60 to +36 dBm. Frequency Error Measures a transmission frequency error of the mobile phone.
5 Description of Screens Stand-by Screen When the Manual Test softkey is pressed on the [Initial] screen, the [Manual Test: Stand-by] Screen (1xEV-DO) as Figure 5-48 is displayed. Figure 5-48 [Manual Test: Stand-by] Screen (1xEV-DO) Softkey Menu Field Softkey Menu 1 • UATI Assign: Executes the UATI assignment. • BS Call: This softkey menu is unavailable at the Stand-by status, and become available at the Session Opened status after UATI Assign completed successfully, then executes BS call.
5 Description of Screens • Trigger: Starts measurement during the Connection status. This softkey is inactivated in the Stand-by status but activated in the Connection status. • More (1 of 3): Displays the Softkey Menu 2. • Return: Returns to the [Initial] screen. Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen.
5 Description of Screens • W-CDMA: Changes the system to W-CDMA. The W00 Option is required. • HSDPA: Changes the system to HSDPA. The W00 and W06 Options are required. • CDMA2000>>: Displays the Softkey Menu 5 to select the cdma2000 system. • Cancel: Cancels selecting a system and returns to the Softkey Menu 2. Softkey Menu 5 • MC-1x: Changes the system to the MC-1x mode on the CDMA Mode. The C00 and C01 Options are required. • 1xEV-DO: This softkey is unavailable.
5 Description of Screens Table 5-24 Entries on the [Manual Test: Stand-by] Screen (1xEV-DO) Input Field Description BS Level * Sets the RF output level of the Tester, ranging from -115.0 to -18.0 dBm in 0.1 dB step. The default value is set on the [Configuration: Test Condition] screen. PER FT Rate Sets the Forward Data Rate (FT Rate) for the packet error rate measurement. The selectable values are: • 307.2 kbps • 2457.6 kbps • 3072.
5 Description of Screens Table 5-25 Information from a Mobile Phone displayed on the [Manual Test: Stand-by] Screen (1xEV-DO) Item Information Description SIG-PTN Displays the value of the Signaling Pattern that is set on the [Configuration: Test Condition] screen. 3GPP2-CONF Displays the value of the 3GPP2-Config that is set on the [Configuration: Test Condition] screen.
Description of Screens 5 Connection Screen When call connection between the mobile phone and the Tester is succeeded, a [Manual Test: Measuring] Connection Screen (1xEV-DO) as Figure 5-49 is displayed. If the trigger mode is set to Cont, continuous measurement of RF test starts when the [Manual Test: Measuring] Connection Screen is displayed. Figure 5-49 [Manual Test: Measuring] Connection Screen (1xEV-DO) Softkey Menu Field Softkey Menu 1 • Connection Close: Starts the Connection Close step.
5 Description of Screens •Switch the Cont trigger mode to Sing (Single measurement) to terminate the measurement. • Trigger: : Starts single measurement of the RF test when the trigger mode is set to Sing and the Trigger softkey is pressed. • More (1 of 3): Displays the Softkey Menu 2. Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen.
Description of Screens 5 Table 5-26 Entries on the [Manual Test: Measuring] Connection Screen (1xEV-DO) Input Item Description RFCH * Specifies the band and channel number. This parameter can be changed when the stand-by or Connection status.
5 Description of Screens Table 5-27 Mobile Phone Information on the [Manual Test: Measuring] Screen (1xEV-DO) Item Information Description ESN Displays the Electronic Serial Number sent from the mobile phone with maximum 8 digits. Pilot Strength Displays the pilot channel measured level at the mobile phone between –13.5 and 0.0 dB when the mobile phone receives the Measurement Report message. Procedure Displays the name of parameter file currently in use.
Description of Screens 5 Code Domain Power Measuring Screen Code Domain Power Measurement measures all test items without the Pass/Fail results.
5 Description of Screens Figure 5-51 [Manual Test] Code Domain Power Screen ("3GPP2 Config" is set to 3 or 4) (1xEV-DO) Softkey Menu Field Softkey Menu • Trigger Sing/Cont: Measures the Code Domain Power. Selects the trigger mode from Sing (single) and Cont (continuous). •If you select the Cont (Continuous measurement) trigger mode, the continuous measurement starts immediately. •Switch the Cont trigger mode to Sing (Single measurement) to terminate the measurement.
Description of Screens 5 Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • Call Drop Timer On/Off: Set Call Drop Timer to On or Off. • More (2 of 2): Returns to the Softkey Menu 1. Screen Field Set the input fields in the screen field according to the following description of Table 5-28 to execute a new test.
5 Description of Screens Table 5-28 Entries on the [Manual Test: Measuring] Screen for Code Domain Power Measurement (MC-1x) Input Item Description Confidence Sets confidence level of the PER Measurement. Selects 95% or Off. Averaging Specifies the average number of the measurement of the TX Power, Frequency Error, Waveform Quality (Multi-code Rho), Origin Offset, Time Offset, Max TX Power, Min TX Power and Code Domain Power measurement. Sets the averaging number from 2 to 99, or Off.
Description of Screens 5 Measuring Screen During connection, RF test can be executed to measure the mobile phone performance before the call is released. Figure 5-52 [Manual Test: Measuring] Measuring Screen (1xEV-DO) Softkey Menu Field Softkey Menu • Trigger Sing/Cont: Starts the RF test. Selects the trigger mode from Sing (single) and Cont (continuous). •If you select the Cont (Continuous measurement) trigger mode, the continuous measurement starts immediately.
5 Description of Screens Table 5-30 Mobile Phone Information on the [Manual Test: Measuring] Screen (1xEV-DO) Item Information Description ESN Displays the Electronic Serial Number sent from the mobile phone, with maximum 8 digits. Pilot Strength Displays the pilot channel measured level at the mobile phone between –13.5 and 0.0 dB when the mobile phone receives the Measurement Report message. Access Probe Power Measures and displays the access probe TX power of the mobile phone.
Description of Screens 5 Result Screen When the measurement is complete, the [Measuring] result screen is displayed. • To disconnect the connection, press the Connection Close softkey. • Press the Session Close softkey to close the session from the tester. When the call is disconnected, the [Manual Test: Stand-by] Result Screen (1xEV-DO) during as Table 5-53 is displayed. • Pass: Displayed on blue background when the measurement is passed.
5 Description of Screens • Trigger Sing/Cont: Executes RF test. Selects the trigger mode from Sing (single) and Cont (continuous). •If you select the Cont (Continuous measurement) trigger mode, the continuous measurement starts immediately. •Switch the Cont trigger mode to Sing (Single measurement) to terminate the measurement. • Trigger: Starts measurement during the Connection status. This softkey is inactivated in the Stand-by status but activated in the Connection status.
Description of Screens 5 • GSM: Changes the system to GSM. The G00 option is required. • GPRS: Changes the system to GPRS. Installation for G00 Option is required. • EGPRS: Changes the system to EGPRS. Installation for G00 Option and G03 Option is required. • W-CDMA: Changes the system to W-CDMA. Installation for W00 Option is required. • HSDPA: Changes the system to HSDPA. Installation for W00 and W06 Options are required. • CDMA2000>>: Displays the Softkey Menu 5 to select the cdma2000 system.
5 Description of Screens TX Analyzer Overview Features of TX Analyzer • This mode is used to test RF transmission performance of a mobile phone without call protocol. Down-link signal setting • The RF On/Off, BS Level and Modulation settings are linked to the [Signal Generator] screen. TX Analyzer settings in Configuration mode • Loss: The path loss values for each band can be set on the [Configuration: Test Condition (Loss)] screen to correct the RF attenuation between the mobile phone and the Tester.
Description of Screens 5 Radio Performance Test in TX Analyzer Table 5-31 describes the measurement items of Radio Performance Test in the TX Analyzer test. Table 5-31 TX Analyzer Measurement Item NOTE Measurement Item Description TX Power Measures the transmission power of a mobile phone. Frequency Error Measures a transmission frequency error of the mobile phone. Multi-code Rho Measures the waveform quality (ρ) of the mobile phone.
5 Description of Screens Stand-by Screen When the TX Analyzer softkey is pressed on the [Initial] screen, the [TX Analyzer: Stand-by] screen as Figure 5-54 is displayed: Figure 5-54 [TX Analyzer: Stand-by] Screen Softkey Menu Field Softkey Menu 1 • RF Output On/Off: Selects the RF signal output from On and Off. • Trigger Sing/Cont: Selects the trigger mode from Sing (single) and Cont (continuous).
Description of Screens 5 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • System >>: Displays the Softkey Menu 3 to select system. • Code Power: Displays the [Code Domain Power] measurement screen. It is displayed only when the Modulation mode is NOT selected to AM Modulation 1 or AM Modulation 2. • More (2 of 2): Returns to the Softkey Menu 1.
5 Description of Screens Table 5-32 Entries on the [TX Analyzer: Stand-by] Screen (continued) Input Item Description RFCH * Specifies the band and channel number. This parameter can be changed in the stand-by status.
Description of Screens 5 The information of Table 5-33 sent from the Tester is displayed on the screen. Table 5-33 TX Analyzer: Stand-by] Screen Information Item Information Description Radio System The CDMA2000 message is displayed at lower left of the screen. 3GPP-SYS Displays the value of the 3GPP System that is set on the [Configuration: Test Sequence] and the [Configuration: Test Condition] screens.
5 Description of Screens Measuring Screen When measurement starts, the [Measuring] screen as shown Figure 5-55 is displayed. Figure 5-55 [TX Analyzer: Measuring] Screen Softkey Menu Field Softkey Menu • Trigger Sing/Cont: Selects the trigger mode from Sing (single) and Cont (continuous). •If you select the Cont (Continuous measurement) trigger mode, the continuous measurement starts immediately. •Switch the Cont trigger mode to Sing (Single measurement) to terminate the measurement.
Description of Screens 5 Result Screen When the measurement is complete, the [TX Analyzer: Stand-by] Result Screen is displayed. The measured results and the acceptance or failure of each item are displayed at the right to the test item. • Pass: Displayed on blue background when the measurement is passed. • Fail: Displayed on red background when the measurement is failed.
5 Description of Screens • More (1 of 2): Displays the Softkey Menu 2. • Return: Returns to the [Initial] screen. Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • System >>: Displays the Softkey Menu 3 to select system. • Code Power: Displays the [Code Domain Power] measurement screen.
Description of Screens 5 Code Domain Power Measuring Screen (MC-1x Mode) During Code Power measurement, all test items are measured but their acceptance or failure is NOT determined. The [TX Analyzer: Stand-by] Code Domain Power Screen (MC-1x) as Figure 5-57 appears if the Modulation mode has been set to Pilot Only, Pilot+Sync+Pch+OCNS+Fch or Pilot+Sync+Pch+OCNS+Fch+Sch (MC-1x mode).
5 Description of Screens • Trigger Sing/Cont: Selects the trigger mode from Sing (single) and Cont (continuous). •If you select the Cont (Continuous measurement) trigger mode, the continuous measurement starts immediately after the [TX Analyzer] screen is displayed. •Switch the Cont trigger mode to Sing (Single measurement) to terminate the measurement. • Trigger: Performs single measurement when the trigger mode is set to Sing. • More (1 of 2): Displays the Softkey Menu 2.
Description of Screens 5 Table 5-34 Entries on the [TX Analyzer: Stand-by] Code Domain Power Screen (MC-1x) Input Item Description RFCH * Specifies the band and channel number. This parameter can be changed when the Stand-by status.
5 Description of Screens Message Field The following message is displayed in the message field on the Connection screens: Press the desired softkey. Code Domain Power Measuring Screen (1xEV-DO Mode) During Code Power measurement, all test items are measured but their acceptance or failure is NOT determined. The Code Power measuring screens of Figure 5-58 and Figure 5-59 are displayed if the Modulation mode has been set to Cont Pilot, Pilot+MAC+Cntr1 or Pilot+MAC+Cntrl+Tch (1xEV-MO mode).
Description of Screens 5 Figure 5-58 Code Power Screen (If "3GPP2 Config" is set to 1 or 2) (1xEV-DO) Figure 5-59 Code Power Screen (If "3GGP2 Config" is set to 3 or 4) (1xEV-DO) Softkey Menu Field Softkey Menu 1 • RF Output On/Off: Selects the RF signal output from On and Off.
5 Description of Screens • Trigger Sing/Cont: Selects the trigger mode from Sing (single) and Cont (continuous). •If you select the Cont (Continuous measurement) trigger mode, the continuous measurement starts immediately after the [TX Analyzer] screen is displayed. •Switch the Cont trigger mode to Sing (Single measurement) to terminate the measurement. • Trigger: Performs single measurement when the trigger mode is set to Sing. • More (1 of 2): Displays the Softkey Menu 2.
Description of Screens 5 Table 5-36 Entries on the [TX Analyzer: Stand-by] Code Domain Power Screen (1xEV-DO) Input Item Description RFCH * Specifies the band and channel number. This parameter can be changed when the stand-by or Connection status.
5 Description of Screens Table 5-37 Mobile Phone Information on the [TX Analyzer] Code Domain Power Screen (1xEV-DO) Item Information Description Radio System The CDMA2000 message is displayed at lower left of the screen. 3GPP-SYS Displays the value of the 3GPP System that is set in the [Configuration: Test Sequence] and the [Configuration: Test Condition] screens. SIG-PTN Displays the value of the Signaling Pattern that is set in the [Configuration: Test Condition] screen.
Description of Screens 5 Signal Generator Overview Features of the Signal Generator The Tester can can output to generate RF signal for cdma2000. NOTE Install the C02 option to use the test function in the 1xEV-DO mode. Signal Generator (Signal Generator) Screen When the Signal Generator softkey is pressed on the [Initial], the [Signal Generator] screen as Figure 5-60 is displayed.
5 Description of Screens • RF Output: Selects the RF power output from On and Off. RF On is shown at the lower left corner of screen when this softkey is set to On. • System >>: Displays the Softkey Menu 2 to select a system. • Return: Returns to the Softkey Menu 1. Softkey Menu 2 • GSM: Changes the system to GSM. The G00 option is required. • W-CDMA: Changes the system to W-CDMA. Installation for W00 Option is required. • CDMA2000: This softkey is unavailable.
Description of Screens 5 Table 5-38 Input field of the [Signal Generator] screen Input Field Description Modulation Specifies the Modulation from the Modulation Data setting and the Modulation Mode setting.
5 Description of Screens Table 5-39 [Manual Test: Measuring] Mobile Phone information on the 1xEV-DO mode connection screen Item Information Description SIG-PTN Displays the value of the Signaling Pattern that is set on the [Configuration: Test Condition] screen. 3GPP2-CONF Displays the value of the 3GPP2-Config that is set on the [Configuration: Test Condition] screen.
Description of Screens 5 Modulation Waveform In this clause, the RF output waveform is described when the Modulation field is set to Off, AM Modulation 1 or AM Modulation 2. When the Modulation is set to Off The Tester outputs continuous wave (CW). The output frequency is set in the RFCH field. The output level is set in the Amplitude field. The output signal is shown in Figure 5-61.
5 Description of Screens Figure 5-62 Waveform (Modulation is set to AM Modulation 1) Amplitude about –0.64 dB about –11 dB fc = –30 kHz fc fc = +30 kHz (fc = RFCH) When the Modulation is set to AM Modulation 2 The Tester outputs DSB-SC (double sideband suppressed carrier) wave. The LSB (lower sideband) frequency is set in the RFCH field. The output signal is shown in Figure 5-63.
Description of Screens 5 Configuration Features of the Configuration Screen In this mode, there are four major functions as follows: • Configuration • Test Sequence • Test Condition • File Management NOTE A changing magnification softkey to input numerical values will be enabled. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on page 4-13.
5 Description of Screens Figure 5-64 [Configuration] screen Softkey Menu Field Softkey Menu 1 • Test Sequence: Displays the [Configuration: Test Sequence] screen. • Test Condition: Displays the [Configuration: Test Condition] screen. • File Management: Displays the [Configuration: File Management] screen. • Network Setting: Displays the [Network Setting] screen. • More (1 of 3): Displays the Softkey Menu 2. • Return: Returns to the [Initial] screen.
Description of Screens 5 Softkey Menu 3 • Debug Data > USB: Outputs debug data into a USB memory device. • More (3 of 3): Returns to the Softkey Menu 1. If option E02 is not installed, setting items for GP-IB are grayed out (disabled) as Figure 5-65. Figure 5-65 Part of the [Configuration] Screen (without Option E02) If option E01 is not installed, setting items for the serial port are grayed out (disabled) as Figure 5-66.
5 Description of Screens Table 5-40 Input items on the [Configuration] Screen Input Field Description Panel Key Restricts operation on the front panel of the tester. Select either Lock or Unlock. • Lock: Functions except Automatic test and Configuration are locked. Test Sequence, Test Condition and File Management are not available in Configuration. • Unlock: No operational restriction on the front panel of the tester.
Description of Screens 5 Table 5-40 Input items on the [Configuration] Screen Input Field Description System Time* Set the system time according to the following format. The System Time is information contained in the cdma2000 broadcast signal. • YYYY: Set the year. The allowable range is from 1990 to 2037. • MM: Set the month. The allowable range is from 01 to 12. • DD: Set the day. The allowable range is from 01 to 31. • HH: Set the hour. The allowable range is from 00 to 23. • MM: Set the minute.
5 Description of Screens Configuration: Test Sequence Screen When the Test Sequence softkey on the [Configuration] screen is pressed, the [Configuration: Test Sequence] Screen (MC-1x) as Figure 5-67, the [Configuration: Test Sequence] Screen (3GPP2 Config is set to 1 or 2 (1xEV-DO Rel. 0)) as Figure 5-68 or [Configuration: Test Sequence] Screen (3GPP2 Config is set to 3 or 4 (1xEV-DO Rev. A)) as Figure 5-69 is displayed. Set test conditions of Automatic Test on this screen.
Description of Screens 5 Softkey Menu Field Softkey Menu • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • Return: Returns to the [Configuration] screen. Automatic Test Flow Refer to the following description and Table 5-42 to set test items for Automatic Test. Select Run to execute the step, or select —— to skip the step in the test flow.
5 Description of Screens Number Item Test 3 Talk Run Run — 4 MS Release Run Run — If you set Call to Run, the corresponding Release will be set to Run. Talk or RF Test is not changed to Run. Number 2 Item Test MS Call (Talk) — → Run → Run (Set) 3 Talk — — — 4 MS Release — — Run If you set Talk or RF Test to Run, Call and Release are changed to Run automatically even though Call is set to ---.
Description of Screens 5 If you change the 11th sequence BS Release to System Handoff, you will have the following result. Number Item Test 10 Softer Handoff Run 11 BS Release Run → Softer Handoff Run System Handoff Run → Softer Handoff Run System Handoff Run (Set) When the Radio System of the sequence-2 is set to -------------, the 7th and 11th steps are fixed to BS Release and may not be configured.
5 Description of Screens Seq.2 Number Item Test 3 Talk Run — 4 MS Release Run — 5 BS Call (Talk) Run — 6 Talk Run — 7 BS Release Run 8 BS Call (RF Test) Run — 9 RF Test Run Run 10 Softer Handoff Run Run 11 BS Release Run Run → — Location Update up to BS Call (RF Test) of the sequence-2 are changed to --- and the invalid display will be released at the same time when the 11th step System Handoff of the sequence-1 is set to BS Release.
Description of Screens 5 Seq.
5 Description of Screens Seq.1 Number Item Test 9 RF Test Run RF Test — 10 Softer Handoff Run Softer Handoff — 11 BS Release Run BS Release — Seq.
Description of Screens 5 Seq.1 Number Item Test 1 Location Update Run Location Update Run 2 MS Call (Talk) Run MS Call (Talk) Run 3 Talk Run Talk Run 4 MS Release Run MS Release Run 5 BS Call (Talk) Run BS Call (Talk) Run 6 Talk Run Talk Run 7 System Handoff Run BS Release (Set) Run 8 BS Call (RF Test) — BS Call (RF Test) — 9 RF Test — RF Test — 10 Softer Handoff — Softer Handoff — 11 BS Release — BS Release — → Seq.
5 Description of Screens Screen Fields Set the input items required to execute tests, referring to the description shown in Table 5-43. Table 5-43 Input items on the [Configuration: Test Sequence] Screen (MC-1x) Input Item Description Test items Specifies execution or skip at each step. Refer to Table 5-42, Test flow item settings (MC-1x). Radio System Radio system of Sequence No. 1 and 2. Select it from cdma2000 MC1x and cdma2000 1xEV-DO.
Description of Screens 5 Table 5-43 Input items on the [Configuration: Test Sequence] (continued)Screen (MC-1x) Input Item Description BS Level (Band) Sets output signal level from the Tester for each band. Band: Selects the band to set the BS level. • 0: Band 0 (Cel US) • 1: Band 1 (PCS US) • 3: Band 3 (Cel JP) • 4: Band 4 (PCS KR) • 6: Band 6 (IMT-2K) BS Level: Sets the BS level for the protocol test and the Access Probe Power measurement. • –115.0 to –18.0 dBm (0.
5 Description of Screens Table 5-43 Input items on the [Configuration: Test Sequence] (continued)Screen (MC-1x) Input Item Description Service Option Sets the service option. Talk • 1:Normal Voice • 3:EVRC 9.6 kVoice • 17:14.4 k Voice • 32768:14.4 k Voice RF Test • 2:9.6 k Data Loop Back • 9:14.4 k Data Loop Back • 55:Data Loop Back The Radio Config and the Service Option settings of after handoff are same value of before handoff.
Description of Screens 5 Table 5-44 Input items on the [Configuration: Test Sequence] Screen (MC-1x) Measurement Item Description Time Offset Sets execution or skip the transmission timing error measurement. Sensitivity/ FER Sets execution or skip the Sensitivity measurement in FER. The signal output level from the Tester and the number of test frames are set on the [Configuration: Test Condition] screen.
5 Description of Screens Figure 5-69 [Configuration: Test Sequence] Screen (3GPP2 Config is set to 3 or 4 (1xEV-DO Rev. A)) Softkey Menu Field Softkey Menu • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • Return: Returns to the [Configuration] screen. Automatic Test Flow Refer to the following description and Table 5-45 to set test items for Automatic Test.
Description of Screens 5 Table 5-45Combination of test item settings (1xEV-DO) Test step Item Test 1 UATI Assignment Run Run Run Run 2 BS Call Run Run Run Run 3 RF Test Run Run – – 4 Softer Handoff Run – Run – 5 Connection Close Run Run Run Run 6 Session Close Run Run Run Run Screen Field Set the input items required to execute tests, referring to the description shown in Table 5-46.
5 Description of Screens Table 5-46 Input items on the [Configuration: Test Sequence] (continued)Screen (1xEV-DO) Input Item Description BS Level (Band) Sets output signal level from the Tester for each band. Band: Selects the band to set the BS level. • 0: Band 0 (Cel US) • 1: Band 1 (PCS US) • 3: Band 3 (Cel JP) • 4: Band 4 (PCS KR) • 6: Band 6 (IMT-2K) BS Level: Sets the BS level for the protocol test and the Access Probe Power measurement. • –115.0 to –18.0 dBm (0.
Description of Screens 5 Table 5-46 Input items on the [Configuration: Test Sequence] (continued)Screen (1xEV-DO) Input Item Description 3GPP System Sets the value for W-CDMA system. This input field exists on the Sequence 1 screen regardless of the radio system setting. * A changing magnification softkey is available. Refer to Storing Numeric Values and Changing Magnification Softkey.
5 Description of Screens Configuration: Test Condition Screen When the Test Condition softkey on the [Configuration] screen, the [Configuration: Test Condition] Screen (MC-1x) as Figure 5-70 or the [Configuration: Test Condition] Screen (1xEV-DO) as Figure 5-71 is displayed depending on the setting of CDMA Mode. When the cdma mode is in MC-1x mode Figure 5-70 shows the [Configuration: Test Condition] screen when cdma mode is set to MC-1x mode.
Description of Screens 5 • Limit: Displays the [Configuration: Test Condition (Limit)] screen. • Return: Returns to the [Configuration] screen. Screen Field Before starting the Automatic Test, Manual Test or TX Analyzer, set the input items required to execute tests, referring to the description shown in Table 5-48. Table 5-48 [Configuration: Test Condition] Screen Input Field (MC-1x) Input Field Description CDMA Mode Sets the CDMA mode to either MC-1x or 1xEV-DO.
5 Description of Screens Table 5-48 [Configuration: Test Condition] Screen Input Field (MC-1x) (continued) Input Field Description Base Station * Set parameters for the base station.
Description of Screens 5 Table 5-48 [Configuration: Test Condition] Screen Input Field (MC-1x) (continued) Input Field Description FER * Set parameters for FER measurement. Set items and the allowable range are as follows: • Max Frames • 25 - 10000000 (107) for a step • Confidence • Set either Off or 95%. Connection Wait * Set connection suspense time for MS Call in a manual test.
5 Description of Screens * A changing magnification softkey is available. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on page 4-13. When CDMA Mode is in 1xEV-DO Mode Figure 3.71 shows the [Configuration: Test Condition] Screen (1xEV-DO) when CDMA mode is set to 1xEV-DO mode.
Description of Screens 5 • Limit: Displays the [Configuration: Test Condition (Limit)] screen. • Return: Returns to the [Configuration] screen. Screen Field Before starting the Automatic Test, Manual Test or TX Analyzer, set the input items required to execute tests, referring to the description shown in Table 5-49. Table 5-49 [Configuration: Test Condition] Screen Input Field (1xEV-DO) Input Field Description CDMA Mode Sets the CDMA to either MC-1x or 1xEV-DO. This is the setting for a manual test.
5 Description of Screens Table 5-49 [Configuration: Test Condition] Screen Input Field (1xEV-DO) (continued) Input Field Description Access Probe * Set parameters for the access probe. Setting Open Loop Adj (Open Loop Adjust) • 0 to -255 (1 dB step) Setting Probe Init Adj (Probe Initial Adjust) • -16 to +15 (1 dB step) Setting Probe Num Step (Probe Num Step) • 1 to 15 Setting Power Step (Power Step) • 0 to 15 (1 step) × 0.
Description of Screens 5 * A changing magnification softkey is available. Refer to Storing Numeric Values on page 4-10 and Changing Magnification Softkey on page 4-13. Configuration: Test Condition (Loss) Screen When the Loss softkey is pressed, [Configuration: Test Condition (Loss)] as Figure 5-72 is displayed.
5 Description of Screens Screen Field Before starting the measurement, set the input items required to execute tests, referring to the description shown in Table 5-50. Table 5-50 Input field on the [Configuration: Test Condition (Loss)] screen Input Field Description Loss* Sets path losses generated by the coupler and cable used to connect mobile phones and radio signals by band. Select On or Off. • On: Take coupling loss setting for RF In/Out into consideration.
Description of Screens 5 Figure 5-73 [Configuration: Test Condition (Limit)] Screen (MC-1x) Softkey Menu Field • Print Screen: Prints a hardcopy of the screen or stores the screen image in a USB memory device, according to the Printer field on the [Configuration] screen. • Return: Returns to the [Configuration: Test Condition] screen. Screen Field The test limits are used by the Tester to judge Pass/Fail for each test in Automatic Test, Manual Test, and TX Analyzer modes.
5 Description of Screens Table 5-51[Configuration: Test Condition (Limit)] Measurement Item (MC-1x) Measurement Item Description CDMA Mode Sets the CDMA Mode to MC-1x or 1xEV-DO. Band Sets the Band to either of: • B0: Cel US • B1: PCS US • B3: Cel JP • B4: PCS KR • B6: IMT-2K Access Probe Power Sets high and low measurement limits of the Access Probe Power. The allowable range is from –99.9 to +99.9 dBm in 0.1 dB steps.
Description of Screens 5 Configuration: Test Condition (Limit) Screen (1xEV-DO) Figure 5-74 shows the [Configuration: Test Condition (Limit)] Screen (MC-1x). Figure 5-74 [Configuration: Test Condition (Limit)] Screen (1xEV-DO) Softkey Menu Field • Print Screen: Prints a hardcopy of the screen or stores the screen image in a USB memory device, according to the Printer field on the [Configuration] screen. • Return: Returns to the [Configuration: Test Condition] screen.
5 Description of Screens Before entering the test limits, make sure that the CDMA Mode and the frequency band are selected correctly for the test limits you are entering. Table 5-52[Configuration: Test Condition (Limit)] Measurement Item (1xEV-DO) Measurement Item Description CDMA Mode Sets the CDMA Mode to MC-1x or 1xEV-DO. Band Sets the Band to either of: • B0:Cel US • B1:PCS US • B3:Cel JP • B4:PCS KR Access Probe Power Sets high and low measurement limits of the Access Probe Power.
Description of Screens 5 Table 5-52[Configuration: Test Condition (Limit)] Measurement Item (1xEV-DO) Measurement Item Description Sensitivity/PER Test 3 (95%) This item is displayed only when the 3GPP2 Config is set to 3 or 4 (1xEV-DO Rev. A). Sets high measurement limit of the Sensitivity/PER Test 3 when the Confidence is set to 95%. The allowable setting range is from 0.0 to 5.0% (0.5% steps).
5 Description of Screens Figure 5-75 [Configuration: File Management] screen Softkey Menu Field Softkey Menu 1 • Save: Saves a file including all test parameters which are currently set into the HDD or a USB memory device. Refer to Saving a Test Setup File. • Recall: Recall one of the test parameter files from the HDD or a USB memory device into the Tester. Refer to Saving a Test Setup File. • Delete: Deletes the test parameter file selected by the CURSOR CONTROL knob.
Description of Screens 5 Softkey Menu 2 • Print Screen: Prints a hardcopy of the screen or saves a graphic file of the screen in a USB memory device depending on the setting of the Printer input field on the [Configuration] screen. • File Replace HDD <- USB: This is displayed when HDD is selected with HDD/USB softkey. Display the file copying screen. Refer to File Replace Confirmation screen (when HDD selected). This softkey is enabled when the following conditions are satisfied.
5 Description of Screens Saving a Test Setup File Save a new parameter file with the following procedure: 1 If you save a file including all parameters that are currently set in a USB memory device, go to step 2. Or, go to step 3 to save a file to the HDD. 2 Insert a USB memory device into the USB Connector on the front panel of the Tester. 3 Select a device you want to use to save a parameter file by toggling the HDD/USB softkey. The selected device, either HDD or USB, is underlined.
Description of Screens 5 Figure 5-77 [Configuration: File Management] Save-2 screen Softkey Menu • Save Now: Saves the parameter file in the HDD or USB memory device. Press this softkey after entering a filename and comment. • Cancel: Cancels saving and returns to the screen in step 4. 6 Change the file name. Press the CURSOR CONTROL knob once to activate the Editor scrolling field.
5 Description of Screens Figure 5-78 [Configuration: File Management] Save-3 screen 7 Turn or press the CURSOR CONTROL knob to select alphanumeric characters and symbols and edit the file name.
Description of Screens 5 Figure 5-79 [Configuration: File Management] Save-4 screen Softkey Menu • Done: Determines the words entered. • Cancel: Cancels editing. • Caps On/Off: Selects upper case or lower case of characters. •On: Selects upper case character •Off: Selects lower case character • Over/Ins: Selects Over (overwrite) or Ins (insert). •Over: Overwrite (erase and replace) characters selected.
5 Description of Screens rectangular cursor is placed at the first position of the Comment field enabling you to enter the first character of a comment. Create a comment with similar operation to that for editing a file name. Refer to step 7 and step 8 to complete creating a comment. Figure 5-80 [Configuration: File Management] Save-5 screen Softkey Menu • Save Now: Executes saving. • Cancel: Cancels entering and returns to the screen in step 5.
Description of Screens NOTE 5 Remove the USB memory device after returning to the [Configuration] screen by pressing the Return softkey. The USB memory device should not be removed while the [File Management] screen is displayed. Otherwise, the parameter files may be damaged. Confirmation message as Figure 3.81 is displayed when you select an existing file and save it as the same file name. Figure 5-81 [Configuration: File Management] Overwrite Screen Softkey menu • Yes: Executes saving.
5 Description of Screens Calling up a test setup file Call up a test setup file in the following procedure. 1 If you recall a file containing test parameters from a USB memory device, go to step 2. Or, go to step 3 to recall a file from the HDD. 2 Insert a USB memory device into the USB Connector to obtain the parameter file list. 3 Select a device you use to recall a test parameter file by pressing the HDD/USB softkey. The selected device, either HDD or USB, is underlined.
Description of Screens 5 Figure 5-83 [Configuration: File Management] Call up-2 screen Softkey • Yes: Executes restoring the parameter file. • No: Cancels recalling the parameter file and returns to step 4. 6 Respond to the operation message Ok to recall? in the message field by pressing the Yes softkey. If there is something to revise, press the No softkey to go back to step 4. 7 When the file has been called up properly in the tester, the file name is displayed in the Procedure area on the table.
5 Description of Screens Figure 5-84 [Configuration: File Management] Call up-3 screen NOTE Remove the USB memory device after returning to the [Configuration] screen by pressing the Return softkey. The USB memory device should not be removed while the [File Management] screen is displayed. Otherwise, the parameter files may be damaged.
Description of Screens 5 4 Move the cursor to the file number of which you want to delete the test parameter file. Figure 5-85 [Configuration: File Management] Delete-1 screen 5 Press the Delete softkey, and then the File Name, Date, Time and Comment fields are highlighted.
5 Description of Screens Figure 5-86 [Configuration: File Management] Delete-2 screen Softkey • Yes: Executes deleting the parameter file. • No: Cancels deleting the parameter file and returns to step 4. 6 Respond to the operation message Ok to delete? in the message field by pressing the Yes softkey. Or, press the No softkey to go back to step 4. 7 When the file is successfully deleted, the file disappears and the softkey menu returns to the initial menu.
Description of Screens 5 Figure 5-87 [Configuration: File Management] Delete-3 screen NOTE Remove the USB memory device after returning to the [Configuration] screen by pressing the Return softkey. The USB memory device should not be removed while the [File Management] screen is displayed. Otherwise, the parameter files may be damaged.
5 Description of Screens File Replace Confirmation screen (when HDD selected) When copying all the test parameter files to a USB memory device, select the HDD with the HDD/USB softkey, and then, press the More (1 of 2) and File Replace HDD > USB softkeys on the [Configuration: File Management] screen. Then, the confirmation screen shown in this Figure 5-88 is displayed. NOTE After this operation, all existing test parameter files in the USB memory device are deleted.
Description of Screens 5 Screen Field The following message appears in the message display area. The selecting procedure file is copied from the hard disk to a USB memory device. When this operation is done, all existing procedure files in the USB memory device are deleted. NOTE If you have saved a new file in the USB memory containing some files copied before, you can restore previous test setup files using the Undo function. Refer to Undo Confirmation screen (when USB memory selected) for details.
5 Description of Screens File Replace Confirmation screen (USB Memory Device is selected) When you select USB memory on the [File Management] screen, press the File Replace HDD < USB softkey to copy the test setup file from USB memory to HDD. Then, the confirmation screen shown in this Figure 5-89 is displayed. NOTE After this operation, all existing test parameter files in the HDD are deleted.
Description of Screens 5 Screen Field The following message appears in the message display area. The selecting procedure file is copied from a USB memory device to the hard disk. When this operation is done, all existing procedure files in hard disk are deleted. NOTE If you have saved a new file on the HDD containing some files copied before, you can restore previous test setup files using the Undo function. Refer to Undo Confirmation screen (when HDD selected) for details.
5 Description of Screens Softkey Menu Field Softkey Menu • Undo Now HDD: Restores all the test parameter files in the HDD before the file replace operation was executed. After this operation, all existing test parameter files in the HDD are deleted. • Cancel: Cancels Undo and returns to the [Configuration: File Management] screen as Figure 5-75. Screen Field The following message appears in the message display area.
Description of Screens 5 Figure 5-91 Undo Confirmation screen (when USB memory selected) Softkey Menu Field Softkey Menu • Undo Now USB: Restores all the parameter files in the USB memory device before the file replace operation was executed. After this operation, all existing test parameter files in the USB memory device are deleted. • Cancel: Cancels Undo and returns to the [Configuration: File Management] screen as Figure 5-75. Screen Field The following message appears in the message display area.
5 Description of Screens Configuration: Network Setting When the Network Setting softkey on the [Configuration] screen is pressed, the [Network Setting] screen as shown in Figure 5-92 appears. Figure 5-92 [Configuration: Network Setting] screen Softkey Menu Field Softkey Menu • Print Screen: Prints the hard-copy of the screen or stores the screen image in the USB memory, according to the Printer setting on the [Configuration] screen.
Description of Screens 5 Screen Field Set the input items required to execute tests, referring to the description shown in Table 5-54. Table 5-54[Configuration: Network Setting] screen Input Item Description IP Addr Set an IP address of the Tester. Possible values are as follows: Allowable range of address values • 1.0.0.1 to 223.255.255.255 (From 192.168.1.1 to 192.168.1.255 are unavailable to setting.) • The IP address setting supports Class A through C.
5 Description of Screens Table 5-54[Configuration: Network Setting] screen (continued) Input Item Description Setting 1 through 5 Set Act/None (active/inactive) of the gateway and the address. The allowable range is as follows: Possible flag values: • None: A default gateway should not be set. • ACT: A default gateway should be set. • If you select None, the field to set an address will be grayed out and cannot be selected.
Description of Screens 5 Table 5-54[Configuration: Network Setting] screen (continued) Input Item Description CIDR Set masks (in CIDR format) for Setting 1 through 5. Possible values are as follows: Possible values for CIDR: • None|1 to 31 • If the CIDR is set to None, the value that is set in Host/Net will be treated as a Host address. • If the CIDR is set to other than None, the value that is set in Host/Net will be treated as a Net address.
5 Description of Screens 5-196 N9360A Multi UE Tester CDMA2000 User Manual
Agilent N9360A Multi UE Tester CDMA2000 User Manual 6 Troubleshooting Items to be checked 6-2 Error Information 6-4 This chapter describes solutions for troubles and error information displayed on the screen.
6 Troubleshooting Items to be checked The symptoms listed below may not be caused by Tester failure. Check the following items before requesting repair. Also, refer to the N9360A Multi UE Tester Installation Guide. Table 6-1 Items to be checked Symptom Section to be checked Remedy The Tester is not activated. Is the external reference A message ERROR!! 0000 signal connected correctly? 1002 Unit initialization failure. is displayed on screen.
Troubleshooting 6 Table 6-1 Items to be checked Symptom Section to be checked Remedy Is the Call Drop Timer set to Off? Set the Call Drop Timer to On. Is there interference from the Shut out external noise by using the shield case, etc. external noise? Is the path loss set correctly? Set the path loss between the Tester and the mobile phone correctly in the Loss field on the [Configuration: Test Condition (Loss)] screen. Connection is lost in the Max TX Power measurement.
6 Troubleshooting Error Information Error Screen Figure 6-1 is an example of the screen that is displayed when an error occurs. The output device (EPSON PM-G800 or USB Memory) is displayed on the lower right corner of the screen when pressing the Print Screen softkey. Figure 6-1 An example of [Error] screen Softkey Menu Print Screen: Prints a hardcopy of the screen or stores the screen image in a USB memory device, according to the Printer field on the [Configuration] screen.
6 Troubleshooting Error codes displayed on error screens Table 6-2 and Table 6-3 list error codes for [Error] screens. If the following guidelines do not help you to remove the errors, contact the Agilent Sales Department or an authorized distributor. Table 6-2 Alarm Notification Error Code Error Code Error Content Action 0000 Abnormal internal temperature 0001 The cooling fan stopped. Turn off power and disconnect the AC plug and contact our sales department or authorized distributor.
6 Troubleshooting Table 6-2 Alarm Notification Error Code Error Code Error Content Action 5001 Time out for waiting for reception of SC response A firmware error occurred. Reboot the Tester.
Troubleshooting 6 Table 6-3 UI Timer Error Code Error Code Error Content 5102 UI timer processing error (2: No relevant timer number for stop order) 5200 UI internal error 6000 UI firmware update error 6100 UI procedure file Check Sum Error Action SC: The application module in the tester N9360A Multi UE Tester CDMA2000 User Manual 6-7
6 Troubleshooting THIS PAGE IS INTENTIONALLY LEFT BLANK.
Agilent N9360A Multi UE Tester CDMA2000 User Manual 7 Performance and Specifications Measurement Performance 7-2 This chapter lists the performance and specifications of the N9360A Multi UE Tester CDMA2000 User Manual. Refer to the N9360A Multi UE Tester Installation Guide about the common specification of the Tester. Refer to the N9360A Multi UE Tester GSM User Manual and N9360A Multi UE Tester WCDMA User Manual for N9360A GSM options and N9360A W-CDMA options respectively.
7 Performance and Specifications Measurement Performance MC-1x Power Measurement Power Measurement specifications are shown on Table 7-1. Table 7-1 Power Measurement Item Specification Unit Measurement range –60 to +36 dBm Resolution 0.01 dB Measurement accuracy –53 to +36 dBm ±1.0 (25 °C ± 5 °C) Remarks Downlink Output Level dB : <–50 dBm ±1.5 (0 °C ± 50 °C) –60 to –53.01 dBm ±1.5 (25 °C ± 5 °C) dB ±2.
7 Performance and Specifications Waveform Quality (Rho/Multi-Code Rho) measurement The specifications of Waveform Quality (Rho/Multi-Code Rho) Measurement are shown on Table 7-3. Table 7-3 Waveform Quality (Rho/Multi-Code Rho) measurement Item Specification Input Level –20 to +36 Measurement Range 0.900 to 0.999 Resolution 0.001 Residential Rho ≥0.990 Unit Remarks dBm Downlink Output Level : <–50 dBm Time Offset measurement Time Offset Measurement specifications are shown on Table 7-4.
7 Performance and Specifications Maximum TX Power Measurement Maximum TX Power Measurement specifications are shown on Table 7-5. Table 7-5 Maximum TX Power Measurement Item Specification Unit Remarks Measurement Range –60 to +36 Resolution 0.01 dB Measurement Accuracy –53 to +36 dBm ±1.0 (25 °C ±5 °C) ±1.5 (0 °C ±50 °C) dB –60 to –53.01 dBm ±1.5 (25 °C ±5 °C) ±2.
Performance and Specifications 7 Access Probe Power Measurement Access Probe Power Measurement specification is shown on Table 7-7. Table 7-7 Access Probe Power Measurement Item Specification Input Level –40 to +36 Unit Remarks dBm Origin Offset Measurement Origin Offset Measurement specifications are shown on Table 7-8. Table 7-8 Origin Offset Item Specification Unit Input Level –20 to +36 dBm Measurement Range –20 to –50 dBc Resolution 0.
7 Performance and Specifications 1xEV-DO Power Measurement Power Measurement specifications are shown on Table 7-10. Table 7-10Power Measurement Item Specification Unit Measurement range –60 to +36 dBm Resolution 0.01 dB Measurement accuracy –53 to +36 dBm ±1.0 (25 °C ±5 °C) ±1.5 (0 °C ±50 °C) dBm –60 to –53.01 dBm ±1.5 (25 °C ±5 °C) ±2.0 (0 °C ±50 °C) dB Remarks Downlink Output Level : <–50 dBm Frequency Error Measurement Frequency Error Measurement specifications are shown on Table 7-11.
7 Performance and Specifications Waveform Quality (Rho/Multi-Code Rho) measurement The specifications of Waveform Quality (Rho/Multi-Code Rho) measurement are shown on Table 7-12. Table 7-12 Waveform Quality (Rho/Multi-Code Rho) measurement Item Specification Input Level –20 to +36 Measurement Range 0.900 to 0.999 Resolution 0.001 Residential Rho ≥0.990 Unit Remarks dBm Downlink Output Level : <–50 dBm Time Offset measurement Time Offset Measurement specifications are shown on Table 7-4.
7 Performance and Specifications Maximum TX Power Measurement Maximum TX Power Measurement specifications are shown on Table 7-14. Table 7-14 Maximum TX Power Measurement Item Specification Unit Remarks Measurement Range –60 to +36 Resolution 0.01 dB Measurement Accuracy –53 to +36 dBm ±1.5 (25 °C ±5 °C) ±1.5 (0 °C ±50 °C) dB –60 to –53.01 dBm ±1.5 (25 °C ±5 °C) ±2.
Performance and Specifications 7 Access Probe Power Measurement Access Probe Power Measurement specification is shown on Table 7-16. Table 7-16 Access Probe Power Measurement Item Specification Input Level –40 to +36 Unit Remarks dBm Origin Offset Measurement Origin Offset Measurement specifications are shown on Table 7-17. Table 7-17 Origin Offset Item Specification Unit Input Level –20 to +36 dBm Measurement Range –20 to –50 dBc Resolution 0.
7 Performance and Specifications THIS PAGE IS INTENTIONALLY LEFT BLANK.
Agilent N9360A Multi UE Tester CDMA2000 User Manual A Appendix A Input Items and Allowable Options or Ranges This chapter contains a table of the input items and allowable options or ranges of values for test parameters and test items. This table is also useful for configuring the [Configuration: Test Sequence] and [Configuration: Test Condition] screens. Refer to the N9360A Multi UE Tester GSM User Manual and N9360A Multi UE Tester WCDMA User Manual when you specify GSM or W-CDMA in the Test Sequence.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges Screen Set Item Set Value Automatic Test RFCH (Band + Channel) BAND 0 (Cel US): 1024 to 1323, 991 to 1023, 1 to 799 |BAND 1 (PCS US): 0 to 1199| BAND 3 (Cel JP): 1041 to 1199, 1201 to 1600, 801 to 1039, 1 to 799 | BAND 4 (PCS KR): 0 to 599 | BAND 6 (IMT-2K): 0 to 1199 BAND 15 (AWS)1:0 ~ 899 Caller ID Manual Test MC-1x CDMA Value Max.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Manual Test (continued) MC-1x (continued) Set Value CDMA (continued) CDMA (continued) –20.00 to –2.50 Averaging Off| 2 to 99 RF Output Off| On Caller ID Value Max. 32 digits, including arbitrary digits (0 to 9) and symbols (2 and #). RX Power Off| On RFCH BAND 0 (Cel US): 1024 to 1323, 991 to 1023, 1 to 799 BS Level –115.0 to –18.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Manual Test (continued) 1xEV-DO (continued) Set Value BAND 0: Cel US BAND 1: PCS US BAND 3: Cel JP BAND 4: PCS KR BAND 6: IMT-2K Configuration (Top Menu) RFCH BAND 0 (Cel US): 1024 to 1323, 991 to 1023, 1 to 799 BS Level –115.0 to –18.0 Per BS Level –115.0 to –18.0 RFCH BAND 1 (PCS US): 0 to 1199 BS Level –115.0 to –18.0 Per BS Level –115.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Configuration (Top Menu)(continued ) GP-IB Set Value Address 1~15 EOI On | Off Terminator CR | LF | CR+LF Date/Time 1990 ~ 2037 MM 1~12 DD 1~31 HH 0~23 MM 0~59 Printer USB Memory | EPSON PM-G800 Beeper On | Off AutoBoot Configuration YYYY Application None |FUNC GSM | FUNC WCDMA | FUNC CDMA2000 Timer 10 ~ 60 Panel Key Serial Port GP-IB
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Configuration (contiinued) System Time Set Value Date/Time Network Setting Ethernet YYYY 1980 to 2030 MM 01 to 12 DD 01 to 31 HH 00 to 23 MM 00 to 59 YYYY 1990 to 2037 MM 01 to 12 DD 01 to 31 HH 00 to 23 MM 00 to 59 IP Addr 1.0.0.1 to 223.255.255.255 CIDR(Mask) 1 to 31 Default Gateway ACT| None Addr 1.0.0.1 to 223.255.255.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Network Setting (continued) Ethernet (continued) Test Condition MC-1x/ 1xEV-DO Common MC-1x Set Value Gateway Setting5 (continued) Host/Net 1.0.0.1 to 223.255.255.255 CIDR (MASK) 1 to 31 | None Gateway 1.0.0.1to 223.255.255.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Test Condition (continued) MC-1x (continued) 1xEV-DO Set Value Off | On Max Slot Cycle Index 0 to 7 Nom Pwr -8 to 7 Init Pwr -16 to +15 Pwr Step 0 to 7 Num Step 0 to 15 Max Req Seq, Max Rsp Seq 1 to 15 Max Tx Power BS Level -115.0 to -18.0 Min Tx Power BS Level -115.0 to -18.
Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Set Value Loss Loss Off | On RF In RF Out Limit A MC-1x B0: Cel US 0.0 to 99.9 B1: PCS US 0.0 to 99.9 B3: Cel JP 0.0 to 99.9 B4: PCS KR 0.0 to 99.9 B6: IMT-2K 0.0 to 99.9 B15: AWS1 0.0 ~ 99.9 B0: Cel US 0.0 to 99.9 B1: PCS US 0.0 to 99.9 B3: Cel JP 0.0 to 99.9 B4: PCS KR 0.0 to 99.9 B6: IMT-2K 0.0 to 99.9 B15: AWS1 0.0 ~ 99.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Limit (continued) MC-1x (continued) 1xEV-DO Set Value Test Item LO, HI Limit (continued ) A-10 MC-1x 0.0 ~ 5.0 Sens/TDSO FER(Off) 0.00 ~ 100.
Appendix A Input Items and Allowable Options or Ranges Table A-1 A Input fields and allowance choices or ranges (continued) Screen Set Item Test Sequence (continued) MC-1x (continued) Set Value MS EXT Control Off| On 3GPP System 1 to 9 Sequence No.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Test Sequence (continued) MC-1x (continued) A-12 Set Value Sequence No. 1 (continued) Service Option F1R1 Talk 1| 3 F2R2 Talk 17| 32768 F3R3 Talk 1| 3 F4R3 Talk 1| 3 F5R4 Talk 17|32768 F1R1 RF Test 2| 55 F2R2 RF Test 9| 55 F3R3 RF Test 2| 55 F4R3 RF Test 2| 55 F5R4 RF Test 9| 55 Wait before paging 0.0 to 99.
Appendix A Input Items and Allowable Options or Ranges Table A-1 A Input fields and allowance choices or ranges (continued) Screen Set Item Test Sequence (continued) MC-1x (continued) Set Value Sequence No. 1 (continued) Sequence No.2 Sensitivity/FER Execution/non-execution selection — | Run ATT In -9.9 to +9.9 ATT Out -9.9 to +9.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Test Sequence (continued) MC-1x (continued) A-14 Set Value Sequence No. 2 (continued) Service Option F1R1 Talk 1| 3 F2R2 Talk 17| 32768 F3R3 Talk 1| 3 F4R3 Talk 1| 3 F5R4 Talk 17| 32768 F1R1 RF Test 2| 55 F2R2 RF Test 9| 55 F3R3 RF Test 2| 55 F4R3 RF Test 2| 55 F5R4 RF Test 9| 55 Wait before paging 0.0 to 99.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Test Sequence (continued) MC-1x (continued) 1xEV-DO Set Value Sequence No. 2 (continued) Sensitivity/FER Execution/non-execution selection — | Run ATT In -9.9 to +9.9 Sequence No. 1 CDMA2000 1xEV-DO Sequence No. 2 CDMA2000 1xEV-DO| ———— Sequence No. 1 to 2 RF Output Auto| On 3GPP System 1 to 9 Sequence No.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Test Sequence (continued) 1xEV-DO (continued) Set Value Sequence No.1 (continued) Sequence No.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Test Sequence (continued) 1xEV-DO (continued) Set Value Sequence No.
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item TX Analyzer CDMA Set Value Radio System Modulation Mode Off| Pilot Only| Pilot+Sync+Pch+OCNS+Fch Pilot+Sync+Pch+OCNS+Fch +Sch| Cont Pilot| Pilot+MAC+Cntrl| Pilot+MAC+Cntrl+Tch| AM Modulation1| AM Modulation2 Modulation method QPSK | 8PSK | 16QAM Averaging Off| 2 to 99 RF Output Off| On RFCH BAND0 (Cel US): 1024 to 1323, 991 to 1023, 1 to 799 Amplitude
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Signal Generator CDMA Set Value Selection of measurement items Off| On Radio System Fixed to CDMA2000 Modulation Pilot Only| Pilot+Sync+Pch+OCNS+Fch Pilot+Sync+Pch+OCNS+Fch +Sch| Cont Pilot| Pilot+MAC+Cntrl| Pilot+MAC+Cntrl+Tch| AM Modulation1| AM Modulation2 Modulation method QPSK | 8PSK | 16QAM Subtype 0| 2 RF Output Off| On RFCH BAND0 (Cel US): 1
A Appendix A Input Items and Allowable Options or Ranges Table A-1 Input fields and allowance choices or ranges (continued) Screen Set Item Set Value Soft Key Screen Simple| Detail| Value Trigger Sing| Cont Magnification change x1| x10| x100| x1000 Caps Off| On Over/Ins Over| Ins 1 The Band15 (AWS Band) is available only when the Option C03 is installed in the Tester. 2 From 192.168.1.1 to 192.168.1.255 are unavailable to setting.
Appendix A Input Items and Allowable Options or Ranges A THIS PAGE IS INTENTIONALLY LEFT BLANK.
A A-22 Appendix A Input Items and Allowable Options or Ranges N9360A Multi UE Tester CDMA2000 User Manual
Agilent N9360A Multi UE Tester CDMA2000 User Manual B Appendix B General information on cdma2000 system Channel frequency and channel number B-2 Frequency band B-2 S/R frequency interval B-3 This appendix describes major information including frequency bands and parameters used in the cdma2000 system.
B Appendix B General information on cdma2000 system Channel frequency and channel number The channel frequencies and channel numbers for each band are shown in Table B-1.
B Appendix B General information on cdma2000 system S/R frequency interval S/R frequency interval is designed as shown in Table B-3.
B Appendix B General information on cdma2000 system 3GPP2 C.S0011-A Recommended minimum Performance Standards for cdma2000 Spread Spectrum Mobile Stations 4.4.5 Maximum RF Output Power 3GPP2 C.S0033A Recommended minimum Performance Standards for cdma2000 High Rate Packet Data Access Terminal 4.3.
Agilent N9360A Multi UE Tester CDMA2000 User Manual C Appendix C N9360A-A02 Antenna Coupler Introduction C-2 Specifications C-2 Operating the Antenna Coupler C-3 This chapter describes information of the Agilent N9360A-A02 Antenna Coupler.
C Appendix C N9360A-A02 Antenna Coupler Introduction Agilent Technologies N9360A-A02 Antenna Coupler enables you to make the RF connection easily between the mobile phone and the Agilent N9360A Multi UE Tester. The purpose of this guide is to provide you with the information on the Agilent N9360A-A02 Antenna Coupler.
Appendix C N9360A-A02 Antenna Coupler C • Inside Diameter: approximately 10 mm • Length: approximately 42 mm Operating the Antenna Coupler 1 If the antenna of the mobile phone can be stretched, fully stretch the antenna. 2 Connect the Antenna Coupler to the RF IN/OUT connector of the Agilent N9360A Multi UE Tester. 3 Insert the antenna into the hole of the Antenna Coupler pushing the Antenna Coupler down to the root of the antenna.
C Appendix C N9360A-A02 Antenna Coupler NOTE Make sure that the coupler is always placed exactly at the same position for each test with the same type antenna. Only in this way can consistent test conditions and test results be assured. 4 Set the attenuation (loss) values on the [Configuration: Test Condition (Loss)] screen. Refer to Entering Loss on the Configuration: Test Condition (Loss) Screen on page 4-22.
Agilent N9360A Multi UE Tester CDMA2000 User Manual D Appendix D Parameters of physical channels Table D-5 Details of the modulation set value in TX Analyzer and Signal Generator D-2 This chapter describes parameters for each physical channel.
D Appendix D Parameters of physical channels Table D-5 Details of the modulation set value in TX Analyzer and Signal Generator MC-1x 1xEV-DO D-2 Set value Modulation Method Remark Pilot Only — Code Channel • Pilot CH (0 dB) Pilot+Sync+Pch+OCNS+Fch — Code Channel • Pilot CH (-7 dB) • Sync CH (-16 dB) • Paging CH (-12 dB) • FCH (-7.4 dB) • OCNS Radio Config: F3R3 FCH Data Rate: 9.
D Appendix D Parameters of physical channels Table D-5 Details of the modulation set value in TX Analyzer and Signal Generator 1xEV-DO (continued) Set value Modulation Method Remark Pilot+MAC+Control+Tch QPSK Code Channel When the 3GPP2 Config is 1 or 2, or the 3GPP2 Config is 3 or 4 and the subtype is 0: • Pilot CH • MAC RA • MAC RPC / DRCLock • DATA CH • Control CH When the 3GPP2 Config is 3 or 4 and the subtype is 2: • Pilot CH • MAC RA • MAC RPC • MAC DRC Lock • DATA CH • Control CH Data Rate a
D Appendix D Parameters of physical channels Table D-5 Details of the modulation set value in TX Analyzer and Signal Generator Set value Modulation Method Remark 1xEV-DO (continued) Pilot+MAC+Control+Tch (continued) 16QAM Code Channel When the 3GPP2 Config is 1 or 2, or the 3GPP2 Config is 3 or 4 and the subtype is 0: • Pilot CH • MAC RA • MAC RPC / DRCLock • DATA CH • Control CH When the 3GPP2 Config is 3 or 4 and the subtype is 2: • Pilot CH • MAC RA • MAC RPC • MAC DRC Lock • DATA CH • Control CH
Agilent N9360A Multi UE Tester CDMA2000 User Manual E Appendix E Softkey Menu Multi-language Introduction 2 This chapter describes the Softkey Menu Multi-language capability of the Tester.
E Appendix E Softkey Menu Multi-language Introduction The Softkey Menu Multi-language is the Tester's capability to switch the softkey menu to the different one. This capability is for the user to operate the Tester by using the softkey menu of the local language. The capability is applicable only to the softkey menu, but not to the screen display.