User manual
Operating Procedures 4
N9360A Multi UE Tester W-CDMA User Manual 4-23
Entering Channel Attenuation on the [Configuration: Test
Sequence] Screen
This section describes correction for the RF Test results in
Automatic Test. Each radio frequency channel (RFCH) path loss
can be set in the [Configuration: Test Sequence] screen. This is
the RF test correction function in addition to the loss function
in the [Configuration] screen.
As well as entering the loss values in the [Configuration] screen,
the user can also enter the attenuation values to be used to
correct the RF test results for each RFCH in the Automatic Test
mode.
Determine and enter the appropriate attenuation values,
caused by the antenna coupler, RF cable or shield case
connecting the mobile phone to the tester, for each RFCH.
The following is the procedure to accomplish the above:
1 Press the W-CDMA softkey on the [Top Menu] screen to
activate W-CDMA system. Refer to
“System Selection" on
page 4-14 for more details.
2 Press the Config softkey on the [Initial] screen and then
the Test Se que nce softkey on the [Configuration] screen to
display the [Configuration: Test Sequence] screen.