Appendix E Description of Radio Performance Test E
N9360A Multi UE Tester W-CDMA User Manual E-17
Minimum TX Power
The tester measures the minimum TX power while it controls
the TX power of the mobile phone by outputting the TPC (–1dB)
continuously.
The output level at the minimum TX power measurement can be
set by Measurement BS level on the [Configuration : Test
Sequence] screen.
ACLR DSB = 10LOG ( (Plower + Pupper)/P0) [dB]
Figure E-16 Minimum TX Power Measurement Image
ACLRDSB 10LOG
P
lower
P
upper
+
P
0
---------------------------------------
⎝⎠
⎛⎞
⎩⎭
⎨⎬
⎧⎫
dB[]=