User manual

E-4 N9360A Multi UE Tester W-CDMA User Manual
E Appendix E Description of Radio Performance Test
Maximum Output Power
The Tester controls the output power of the mobile phone to the
maximum by transmitting TPC (+1dB) continuously. The Tester
measures the output power of the mobile phone at this time and
the measurement unit is dBm.
The Tester output level for Maximum Output Power can be set at
the Measurement BS Level input field on the [Configuration: Test
Sequence] screen.
Figure E-3 Maximum Output Power Measurement Image
Figure E-4 Maximum Output Power Measurement Flow
Start maximum o utput po wer
measurement
Measurement
End measurement
Display the measurement
result on the screen
Go to the next test
Set the Tester o utput
power to -93dBm
Continuous transmission o f
TPC[+1dB]
Mobile phone:
Maximum o utput po wer