User manual

5-162 N9360A Multi UE Tester W-CDMA User Manual
5 Screen Reference
W-CDMA Mode is set to HSDPA
Screen Field
The following input fields need to be set in order to initiate Test
Conditions. The descriptions of the fields are listed in
Table 5-49.
Table 5-49 [Configuration: Test Condition] Screen Input Field
Input Field Description
Current system Displays an active Tester.
Selects a test mode from "GSM", "W-CDMA" and "CDMA2000". GSM is valid when G00 Option
is installed in the Tester. CDMA2000 is valid when cdma2000 Option is installed in the Tester.
W-CDMA Mode Selects W-CDMA Mode from W-CDMA or HSDPA. This item is selectable only when the Option
W06 is installed and valid 3GPP system is existing in the Tester.
Band Sets a band to 1 or 6. This setting is for Manual Test, TX Analyzer and Signal Generator.
3GPP System Selects 3GPP version and the protocol.
This parameter is fixed to 4.
Signaling Pattern † Sets a signaling pattern. The allowable range is from 1 to 255 in 1 step.
Select 1 at present because settings over 2 will be extended in future.
BS Level † Sets a RF output level for selected band. This setting is for Manual Test, TX Analyzer and Signal
Generator. Also, this setting can be done on the each test screen. The allowable range is from
-115.0 to -18.0 dBm in 0.1 dB step.
Meas. Type † Sets measurement period mode and measurement period number.
Measurement period mode is selected from TTI and CQI.
Allowable range of measurement period number is from 1 to 100000 in 1 step.
TTI
Measurement period is defined by the TTI period shown by the measurement period number.
The parenthesized value is calculated by "measurement value * 2ms".
CQI
Measurement period is defined by how long it takes before attaining the CQI reporting value
shown by the measurement period number.
H-ARQ retrans Sets the time of retransmission of H-ARQ.
Select 1 or 4.
Data Sets the HSDPA transmission data.
This parameter is fixed to "PN15".
TPC Algorithm Sets the algorithm of power control to 1 or 2 for Manual Test. This parameter is fixed to 1 for
Automatic Test.