Screen Reference 5
N9360A Multi UE Tester W-CDMA User Manual 5-159
W-CDMA Mode Selects W-CDMA Mode from W-CDMA or HSDPA. This item is selectable only when the Option
W06 is installed and valid 3GPP system is existing in the Tester.
Band Sets a band to from 1 to 6. This setting is for Manual Test, TX Analyzer and Signal Generator.
3GPP System Selects 3GPP version and the protocol. Contact the Agilent Sales Department about
corresponding mobile phones.
The parameter is 1, 2, 3 or 4.
Signaling Pattern † Sets a signaling pattern. The allowable range is from 1 to 255 in 1 step.
Select 1 at present because settings over 2 will be extended in future.
BS Level † Sets a RF output level for selected band. This setting is for Manual Test, TX Analyzer and Signal
Generator. Also, this setting can be done on the each test screen. The allowable range is from
-115.0 to -18.0 dBm in 0.1 dB steps.
BER Frames † Sets the number of test frames for BER measurement. This setting is for Manual Test.
Also, this setting can be done on the [Manual Test] screen.
The allowable range is from 1 to 4100 in 1 step.
(1 Frame = 1 TTI)
Also, a bit number according to BER Frames is displayed between parentheses. The bit number
is calculated by an equation "BER Frames multiplied by 244". While BER Frames is entered, The
bit number is displayed in conjunction with the value of BER Frames.
Averaging Averages respective measurement values of Frequency Error and EVM.
Set the averaging number from 2 to 99 or "Off".
When this function is not required, select "Off".
This setting is for Automatic Test, Manual Test and TX Analyzer.
Also, this setting can be done on the [Manual Test] and the [TX Analyzer] screen.
Data Sets transmit data to "PN9" or "PN15".
This setting is for Automatic Test and Manual Test.
Loopback Delay Sets voice loopback delay for Talk test to "Short", "Mid" or "Long".
This setting is for Automatic Test and Manual Test.
Connection Wait Sets the connection response function for MS Call in Manual Test. The allowable range is from 0
to 120 in 1 sec step. A parameter value sets the way to respond.
• 0: The Tester automatically responds to MS Call immediately.
• 1 to 120: Sets a time out of waiting for response. After the time is over, the Tester
automatically responds to the call.
TPC Algorithm Sets the algorithm of power control to 1 or 2 for Manual Test. This parameter is fixed to 1 for
Automatic Test.
Table 5-47 [Configuration: Test Condition] Screen Input Field
Input Field Description