User manual

Screen Reference 5
N9360A Multi UE Tester W-CDMA User Manual 5-155
Detail of RF Test Sets measurement methods for six channels.
RFCH †: Sets the uplink channel number to execute a test.
A band symbol is also displayed. Each band symbol corresponds to a band as follows.
B1: Band 1
B2: Band 2
B3: Band 3
B4: Band 4
B5: Band 5
B6: Band 6
The allowable range is as follows:
Band 1:9600 to 9900 (1920.0 MHz to 1980.0 MHz)
Band 2: 9250 to 9550 (1850.0 MHz to 1910.0 MHz)
12 (1852.5 MHz), 37 (1857.5 MHz),
62 (1862.5 MHz), 87 (1867.5 MHz),
112 (1872.5 MHz), 137 (1877.5 MHz),
162 (1882.5 MHz), 187 (1887.5 MHz),
212 (1892.5 MHz), 237 (1897.5 MHz),
262 (1902.5 MHz), 287 (1907.5 MHz)
Band 3: 8550 to 8925 (1710.0 MHz to 1785.0 MHz)
Band 4: 8550 to 8775 (1710.0 MHz to 1755.0 MHz)
1162 (1712.5 MHz), 1187 (1717.5 MHz),
1212 (1722.5 MHz), 1237 (1727.5 MHz),
1262 (1732.5 MHz), 1287 (1737.5 MHz),
1312 (1742.5 MHz), 1337 (1747.5 MHz),
1362 (1752.5 MHz)
Band 5: 4120 to 4245 (824.0 MHz to 849.0 MHz)
782 (826.5 MHz), 787 (827.5 MHz),
807 (831.5 MHz), 812 (832.5 MHz),
837 (837.5 MHz), 862 (842.5 MHz)
Band 6: 4150 to 4200 (830.0 MHz to 840.0 MHz)
812 (832.5 MHz), 837 (837.5 MHz)
"---" denotes skip. RFCH1 cannot be set to "---".
ATT In a: Sets attenuation values for receiving. The allowable range is -9.9 to +9.9 in 0.1 steps.
ATT Out a: Sets attenuation values for transmission. The allowable range is -9.9 to +9.9 in 0.1
steps.
Sets execution or skip for the following each RF test. Set each item to "Run" or "---".
Open Loop TX Power (only for CH1)
ILP (Inner Loop Power)
MAX TX Power
Frequency Error
EVM
Sensitivity/BER
Table 5-46 [Configuration: Test Sequence] Screen Input Field
Input Field Description