User manual
Screen Reference 5
N9360A Multi UE Tester W-CDMA User Manual 5-153
Screen Field
The following input fields need to be set in order to execute
Automatic Test. The descriptions of the fields are listed in
Table 5-46. This manual explains when W-CDMA is selected for
Sequence1 or Sequence2. Refer to the N9360A Multi UE Tester
GSM User Manual when you select "GSM850", "GSM900",
"DCS1800", or "PCS1900". Also, refer to the N9360A Multi UE
Tester cdma2000 User Manual when you select "MC-1x" or
"1xEV-DO".
System Handover test requires the following conditions:
• Select any band while Sequence1 is set to W-CDMA and
Sequence2 is set to GSM.
• Set 3GPP System to 2, 3, or 4.
When above two conditions are satisfied, BS Release/Handover
shift becomes available. Select Handover to execute System
Handover.
When Sequence 1 and Sequence 2 are set to W-CDMA, up to 12
channels can be measured by using Handover function. Set the
end of
BS Call (RMC) of Sequence 1 to Handover instead of BS Release.
Table 5-46 [Configuration: Test Sequence] Screen Input Field
Input Field Description
Radio System Sets the radio system of Sequence 1 and Sequence 2. Required options are in parentheses.
• GSM850, GSM900, DCS1800 or PCS1900 (G00)
• W-CDMA (W00)
• CDMA2000 MC-1x (C00, C01)
• CDMA2000 1xEV-DO (C00, C01, C02)
• "-----" (Displays in Radio System 2. When using only the Sequence 1, this item is selected.)
When "CDMA2000 1xEV-DO" is set in the Sequence 1 of the Radio System, "CDMA2000
1xEV-DO" is able to set in the Sequence 2.
Sequence No. Selects the number of the sequence to switch the screen between Sequence 1 and Sequence 2
in order to configure the screen of the Sequence.