5 Screen Reference
† The changing magnification softkey is available. Refer to “Storing Numeric Values" on
page 4-10 and “Changing Magnification Softkey" on page 4-13.
‡ Refer to “Physical Channel Parameters of Signal Generator" on page D-2 about the
parameters of physical channel for transmitting and receiving in the Signal Generator
mode.
The following are also displayed on the screen field:
3GPP-SYS and SIG-PTN
The 3GPP system and the signaling pattern that are
currently set on the Configuration: Test Condition
screen are displayed at the lower-right corner of the
screen.
RF On indicator
"RF On" indicator at the lower-left corner of the screen is
displayed only when the RF signal from the tester is
output to the RF In/Out connector.
UE Category (Option
W06)
Sets UE Category.
Allowable range is from 1 to 6, 11, and 12.
The setting range of Modulation Type and Ec/Ior are varied by the combination of FRC Type and
UE Category.
Refer to Ta ble 5-2 9.
Ec/Ior
(Option W06)
Sets the code power of the DPCH, HS-SCCH, HS-PDSCH by fixed combination.
The available combination is defined by the combination of the FRC Type, Modulation Type, UE
Category.
The HS-PDSCH code power stated above is the total amount of HS-PDSCH code power of each
Channlisation Code.
Refer to Ta ble 5-2 9.
OCNS Selects "On" or "Off".
On: Adds OCNS to Modulation signal.
Off: Does not add OCNS to Modulation signal.
When Modulation is set to IDLE, OCNS setting is invalid and "---" is displayed.
When IDLE+DPCH + H-Set1 to H-Set5 or CQI-1 to CQI-30 are selected for Modulation, OCNS is
fixed to "On”.
Table 5-43 [Signal Generator] Screen Input Field
Input Field Description