User manual
Screen Reference 5
N9360A Multi UE Tester W-CDMA User Manual 5-87
RFCH † Sets the uplink channel number to execute a test.
A band symbol is also displayed. Each band symbol corresponds to a band as follows.
• B1: Band 1
• B2: Band 2
• B3: Band 3
• B4: Band 4
• B5: Band 5
• B6: Band 6
The allowable range is as follows:
• Band 1:9600 to 9900 (1920.0 MHz to 1980.0 MHz)
• Band 2: 9250 to 9550 (1850.0 MHz to 1910.0 MHz)
12 (1852.5 MHz), 37 (1857.5 MHz),
62 (1862.5 MHz), 87 (1867.5 MHz),
112 (1872.5 MHz), 137 (1877.5 MHz),
162 (1882.5 MHz), 187 (1887.5 MHz),
212 (1892.5 MHz), 237 (1897.5 MHz),
262 (1902.5 MHz), 287 (1907.5 MHz)
• Band 3: 8550 to 8925 (1710.0 MHz to 1785.0 MHz)
• Band 4: 8550 to 8775 (1710.0 MHz to 1755.0 MHz)
1162 (1712.5 MHz), 1187 (1717.5 MHz),
1212 (1722.5 MHz), 1237 (1727.5 MHz),
1262 (1732.5 MHz), 1287 (1737.5 MHz),
1312 (1742.5 MHz), 1337 (1747.5 MHz),
1362 (1752.5 MHz)
• Band 5: 4120 to 4245 (824.0 MHz to 849.0 MHz)
782 (826.5 MHz), 787 (827.5 MHz),
807 (831.5 MHz), 812 (832.5 MHz),
837 (837.5 MHz), 862 (842.5 MHz)
• Band 6: 4150 to 4200 (830.0 MHz to 840.0 MHz)
812 (832.5 MHz), 837 (837.5 MHz)
BS Level † Sets a RF output level of the Tester. The allowable range is from -115.0 to -18.0 dBm in 0.1 dB
steps.
BS Call Selects "AMR" or "RMC" for BS Call in execution.
PWR CNTL Sets the power control level of the mobile phone to "HOLD", "CNT UP", or "CNT DWN" and also
sets a control value.
• HOLD: Sets HOLD
• CNT UP: Increases the power continuously.
• CNT DWN: Decreases the power continuously.
Set TPC Algorithm at "TPC Algorithm" field on the [Configuration: Test Condition] screen.
The allowable range for the control value is from 1 dB to 99 dB in 1 dB step.
Caller ID Sets if the Tester displays an addresser number on the screen or not.
• On: Displays the number
• Off: Not display the number
Table 5-23 [Manual Test] Measurement Result Screen Input Field
Input Field Description