User manual
5-64 N9360A Multi UE Tester W-CDMA User Manual
5 Screen Reference
Procedure Displays a list of parameter file names stored in the Tester for selection if the Tester contains
parameter files. Select a file to recall parameters for a test.
If the Tester is using a parameter file, the file name is shown in this field.
RFCH † Sets the uplink channel number to execute a test.
A band symbol is also displayed. Each band symbol corresponds to a band as follows.
• B1: Band 1
• B2: Band 2
• B3: Band 3
• B4: Band 4
• B5: Band 5
• B6: Band 6
The allowable range is as follows:
• Band 1: 9600 to 9900 (1920.0 MHz to 1980.0 MHz)
• Band 2: 9250 to 9550 (1850.0 MHz to 1910.0 MHz)
12 (1852.5 MHz), 37 (1857.5 MHz),
62 (1862.5 MHz), 87 (1867.5 MHz),
112 (1872.5 MHz), 137 (1877.5 MHz),
162 (1882.5 MHz), 187 (1887.5 MHz),
212 (1892.5 MHz), 237 (1897.5 MHz),
262 (1902.5 MHz), 287 (1907.5 MHz)
• Band 3: 8550 to 8925 (1710.0 MHz to 1785.0 MHz)
• Band 4: 8550 to 8775 (1710.0 MHz to 1755.0 MHz)
1162 (1712.5 MHz), 1187 (1717.5 MHz),
1212 (1722.5 MHz), 1237 (1727.5 MHz),
1262 (1732.5 MHz), 1287 (1737.5 MHz),
1312 (1742.5 MHz), 1337 (1747.5 MHz),
1362 (1752.5 MHz)
• Band 5: 4120 to 4245 (824.0 MHz to 849.0 MHz)
782 (826.5 MHz), 787 (827.5 MHz),
807 (831.5 MHz), 812 (832.5 MHz),
837 (837.5 MHz), 862 (842.5 MHz)
• Band 6: 4150 to 4200 (830.0 MHz to 840.0 MHz)
812 (832.5 MHz), 837 (837.5 MHz)
BS Level † Sets a RF output level of the Tester. The allowable range is from -115.0 to -18.0 dBm in 0.1 dB
steps.
BS Call Selects "AMR" or "RMC" for BS Call in execution.
PWR CNTL Sets the power control level of the mobile phone to "HOLD", "CNT UP", or "CNT DWN" and
also sets a control value.
• HOLD: Sets HOLD
• CNT UP: Increases the power continuously.
• CNT DWN: Decreases the power continuously.
Set TPC Algorithm at "TPC Algorithm" field on the [Configuration: Test Condition] screen.
The allowable range for the control value is from 1 dB to 99 dB in 1 dB step.
Table 5-18 [Manual Test: Stand-by] Screen Input Field
Input Field Description