User manual
Screen Reference 5
N9360A Multi UE Tester W-CDMA User Manual 5-63
Softkey Menu 3
GSM: Changes the system to GSM. The G00 Option is required.
GPRS: Changes the system to GPRS. The G00 Option is required.
EGPRS: Changes the system to EGPRS. The G00 Option and G03
Option are required.
W-CDMA: This softkey is unavailable.
HSDPA: Changes the system to HSDPA. The W06 Option is
required.
CDMA2000>>: Displays the softkey menu 4 to select system of
cdma2000.
Cancel: Cancels selecting system and returns to the softkey
menu 2.
Softkey Menu 4
MC-1x: Changes the system to cdma2000 Mc-1x. The C00 Option
and C01 Option are required.
1xEV-DO: Changes the system to cdma2000 1xEV-DO. The C00
Option, C01 Option and C02 Options are required.
Cancel: Cancels selecting system and returns to the softkey
menu 3.
Screen Field
Set the input fields in the screen field according to the
description in Table 5-18 to execute a new test.
Table 5-18 [Manual Test: Stand-by] Screen Input Field
Input Field Description
Measurement item
selection
Sets whether or not to execute a group of measurement items or each measurement item.
• TX Power
• Frequency Error
• EVM, Origin Offset
• BER
• Selects "On" or "Off".
• On: Executes the measurement item.
• Off: Skips the measurement item.
• Refer to Tab le 5 -17 about the details of measurement items.