Automatic Test
Overview
Feature of Automatic Test
Pass/Fail test results in the test flow and measurement
items are automatically obtained.
This function executes RF test switching frequencies on
up to six channels automatically. Combining Sequence 1
and Sequence2 enables measurement on up to 12
channels in one test.
System handover from Sequence1 to Sequence2 can be
executed when the G00 Option is installed.
Automatic Test Setting in Configuration Mode
Parameters:
The parameters used in Automatic Test are set in the
Configuration: Test Sequence and the Configuration:
Test Condition screen.
Loss:
The path loss values for each band can be entered on the
Configuration screen to correct the RF attenuation
between the mobile phone and the Tester. Refer to
“Actual Input/Output Level and Correction" on page 4-19
for correction of input/output signal.
ATT In/Out:
The path loss values for each RFCH can be set on the
Configuration: Test Sequence screen to correct the RF
test results at each RFCH in a band.
Sequence:
Up to two test sequences can be set in the Configuration:
Test Sequence screen.
Each of W-CDMA and GSM can be set for Sequence 1 and Sequence 2. To
execute system handover from Sequence 1 to Sequence 2, set the
Sequence 1 to W-CDMA and the Sequence 2 to GSM.
This manual explains test items only for W-CDMA. Refer to the N9360A
Multi UE Tester GSM User Manual and the N9360A Multi UE Tester
cdma2000 User Manual for GSM and cdma2000 test items.