Technical data
64 Programmer’s Guide
5 Command Reference
DC Power In Type
:SYSTem:CONFigure:DCPI STANDBY|PWRON
:SYSTem:CONFigure:DCPI?
This command toggles the DC power in type between standby and
power on. When it is set to standby, the analyzer will be in standby
mode after the power is plugged in. When it is set to power on, the
analyzer will be in power on mode once the power is plugged in.
Key access: Shift > System > Pwr On/Off Preset > DC Pwr In
Low Frequency Channel Status
:SYSTem:CONFigure:LFCHannel OFF|ON|0|1
:SYSTem:CONFigure:LFCHannel?
Use this command to turn on/off the low frequency channel status.
Key access: Freq > More > Low Frequency
Power Reset
:SYSTem:POWer:RESet
Use this command to restart the instrument.
Power Off
:SYSTem:POWer:OFF
Use this command to turn off the instrument.
Speaker Volume
:SYSTem:SPEaker <value>
:SYSTem:SPEaker?
Use this command to adjust the volume of the speaker.
Example: :SYSTem:SPEaker 20