Technical data

140 Programmer’s Guide
5 Command Reference
CAT Amplitude Scale Per Division
[:SENSe]:CAT:SCALe:DIV <value>
[:SENSe]:CAT:SCALe:DIV?
This command defines the amplitude display scale per division.
Range: 0.1 to 10
Example: :CAT:SCALe:DIV 5
Key access: Meas > Start Distance
CAT Save Trace Data to Memory
[:SENSe]:CAT:TRACe:SAVE
Use this command to save the current trace data to memory.
Example: :CAT:TRACe:SAVE
Key access: Trace > Data >Mem
CAT Trace Display Type
[:SENSe]:CAT:TRACe:DISPlay DATA|MEM|DAM
[:SENSe]:CAT:TRACe:DISPlay?
This command toggles the trace display type. cable and antenna
measurement mode supports three display type, displaying current
measurement result, displaying the trace data saved in memory, and
display both the data saved in memory and current sweep result.
Range: DATA, MEM, DAM
Example: :CAT:TRACe:DISPlay MEM
Key access: Trace> Data / Memory / Data&Memory