Specifications
14
The field strength measurement
automatically takes into the account of
the antenna factor. The antenna table
is definable by the standard N9340B PC
software.
Field strength measurement
Electric field strength measurements are frequently required for field testing
of transmitter and antenna coverage. Field strength measurements are now a
standard function in the N9340B. Calibrated field strength measurements are
easy to make once the antenna factors are loaded into the analyzer via the
provided PC software based antenna template. Either field strength (in dBμV/m,
dBmV/m, or V/m) or power flux density (in dBm/m or W/m) can be displayed.
With the amplitude offset function, the user can correct gain or loss. And finally
together with the user-definable multi-limit line function, the N9340B offers the
user quick and convenient field strength measurements and analysis.