Agilent N9340B Handheld Spectrum Analyzer (HSA) 3 GHz Technical Overview Field testing just got easier
Front panel 1 6 2 3 7 4 5 8 Top panel 9 10 12 11 13 14 15 Front panel Top panel 1. 6.5 TFT display 9. RF INPUT (50 Ω) 2. Light sensor 10. EXT TRIG IN/EXT REF IN 3. Speaker 11. RF OUT (50 Ω) 4. Soft keys 12. Power input (55 W Max) 5. Back-lit keys 13. USB connectors 6. Power on/off 14. Headphone connector 7. Function keys 15. LAN connector 8.
N9340B superior performance ensures the field test confidence • Superior sensitivity: Lowest DANL in-the-class • Fastest sweep time • Narrowest resolution available • Frequency range: 100 kHz to 3 GHz (tunable to 9 kHz) 1 • DANL: (RBW = 30 Hz, 10 MHz < fc ≤ 1.
N9340B applications for field test • Aerospace and defence: Radio and radar test, interference analysis, on-site repair • Wireless service providers: Interference analysis, on-site repair • TV and broadcasting: Interference analysis, channel power check • Spectrum management authority: Spectrum monitoring N9340B is now equipped with powerful features to address field applications using a handheld spectrum analyzer. An analysis is identifying interfering signals.
Extended spectrogrammonitoring (Option INM) Option INM extends the N9340B spectrogram capability further with the ability to continuously monitor and save spectrogram data over time not only to the analyzer’s internal memory or a USB flash drive, but also directly to a PC. With option INM users can save more than 1,500 continuous frames of data depending on the size of the USB flash drive or PC memory. Option INM also supports an Automatic Save function.
DSL measurements (Option XDM) xDSL (ADSL and VDSL) is widely used for broadband internet connections at homes and businesses. Service providers occasionally face problems with interference on their xDSL lines. The interference is mainly intermittent intrusion from nearby external sources such as electric motors, elevators, and appliances. In order to monitor, capture and remove intermittent interference, the engineer may need to work in the field for extended periods of time.
IBOC measurements (Option IBC) N9340B IBC also supports a onebutton auto-tune function that greatly simplifies the otherwise complex user setup required to capture and measure IBOC signals of interest. The auto-tune function will automatically set the frequency span, RBW, Average and Detector types, etc. It only takes seconds for the auto-tune function to display the correct measurement results.
One-button measurement The Agilent N9340B supports one-button measurements of occupied bandwidth, channel power and adjacent channel power ratio. This virtually eliminates set-up time in the field. Occupied bandwidth (OBW) An occupied bandwidth measurement integrates the power of the displayed spectrum and puts one pair of vertical lines at the frequencies between which the interested signal is contained.
Channel power Use channel power to measure both power and power spectral density in a user-specified channel bandwidth. One pair of vertical lines on the display indicates the edges of the channel bandwidth. It is quick and easy to set center frequency integration bandwidth, and channel bandwidth. Adjacent channel power ratio (ACPR) Wireless service providers need to minimize the interference caused by power leaking into adjacent transmit channels.
Spectrum emission mask (SEM) The new N9340B adds Spectrum Emission Mask (SEM) as a standard feature. SEMis a mask for out-of-channel emissions measurement. The SEMis defined relative to in-channel power. The user can set the parameters of the main channel, out-of-channel frequency bands, and the limit lines. Included is Pass/Fail testing for the overall spectrum emission mask and each individual out-of-channel frequency range.
AM/FM modulation analysis (Option AMA) Optional AM/FM modulation analysis shows the metrics you need, including carrier power, modulation rate, AM depth/FM deviation, SINAD and carrier frequency offset. User definable limits provide Pass/Fail indicators in 4 cases: higher than carrier power, larger than AM modulation index or FM deviation, lower than AM modulation index or FM deviation, or larger than carrier frequency offset.
ASK/FSK modulation analysis (Option DMA) Optional ASK/FSK modulation analysis is now available. Amplitude Shift Keying (ASK) is used in RFID and optical systems. Frequency Shift Keying (FSK) is used in many applications including cordless phone, paging system and RFID. N9340B with option DMA supports 4 display modes: Symbol, Waveform, ASK/FSK Error, and Eye Diagram.
High accuracy power measurement The N9340B now supports high-accuracy, USB plug-and-play power measurements as standard when connected to an Agilent U2000 series USB power sensor. Make true average power measurements for all signal types with wide dynamic range up to 18 GHz with just the push of a button. The Agilent U2000 USB sensors require no external power supplies and with internal zeroing eliminate the need for external calibration.
Field strength measurement Electric field strength measurements are frequently required for field testing of transmitter and antenna coverage. Field strength measurements are now a standard function in the N9340B. Calibrated field strength measurements are easy to make once the antenna factors are loaded into the analyzer via the provided PC software based antenna template. Either field strength (in dBμV/m, dBmV/m, or V/m) or power flux density (in dBm/m or W/m) can be displayed.
Channel table For the users who prefer to tune the spectrum analyzer according to channel numbers rather than center frequency, you will find the new Channel Table feature easy-to-use. The Channel Table includes the major wireless communication standards, such as AMPS, GSM/EDGE/GPRS, CDMA, CDMA2000 etc. The Channel Table can also be edited by the user with the included N9340 PC Software. The revised Channel Table can be downloaded to the analyzer via a PC USB cable or a USB memory stick.
N9340B optimized usability to enhance field test productivity • 6.5’’ TFT screen with bright display for use indoors and outdoors • Back-lit keys for night use • Four-hour battery life • Modern USB and LAN connectivity for data transfer and remote control • Multi-language User Interface • Rugged design, MIL-PRF 28800F Class 2 compliance A standard soft carrying case provides further protection for your analyzer.
Modern USB and LAN connectivity Remote control N9340B via SCPI over USB/LAN is now available! Detailed analysis of results in the field is not Remote control N9340B via SCPI over USB/LAN is now available! always convenient or possible. You will need to store the results for later investigation. N9340B supports USB memory stick for data storage and retrival. It makes it easy to transfer and safeguard your measurement data. Connecting to a PC is simple and data transfer is fast via the USB cable.
Specifications Specifications apply under the following conditions: • After a warm-up time of 30 minutes, and at least two hours of operation or storage at operating temperature. • Within a valid calibration period • Data with no given tolerances are typical values only. Data designated as ‘typical’ is not covered by the product warranty.
Specifications (continued) Amplitude Measurement range Supplemental information Input attenuator range Displayed average noise level (DANL) to +20 dBm 0 to 51 dB, in 1 dB steps Average continuous power ≥ +33 dBm; 3 minutes maximum. Nominal DC voltage 50 VDC maximum Maximum safe input level Displayed average noise level Preamp off 100 kHz < fc ≤ 1 MHz 1 MHz < fc ≤ 10 MHz 10 MHz < fc ≤ 1.5 GHz 1.5 GHz < fc ≤ 3 GHz fc = 50 MHz fc = 1.
Specifications (continued) Amplitude (continued) RF Input VSWR (at tuned frequency) Attenuator setting 0 dB Attenuator setting 10 dB Supplemental information < 1.8 : 1 < 1.8 : 1 < 1.5 : 1 < 1.8 : 1 < 1.6 : 1 < 1.4 : 1 10 MHz to 3.0 GHz, Nominal 100 kHz to 10 MHz, Nominal 10 MHz to 2.5 GHz, Typical 2.5 GHz to 3.0 GHz, Typical 100 kHz to 10 MHz, Nominal 10 MHz to 3.
Specifications (continued) General Display Resolution Size and type Internal memory Supplemental information 640 x 480 pixels 6.
Specifications (continued) Options Spectrogram Monitoring (Option INM) 3 display modes Supplemental information Spectrogram Spectrum trace Combination of spectrogram and spectrum trace in one screen Low frequency performance enhancement and xDSL measurement capability (Option XDM) XDM channel DANL Preamp off 9 kHz to 12 MHz 30 Hz RBW, 3 Hz VBW, 50 Ω termination on input, 0 dB attenuation, RMS detector, Trace Average ≥ 40 9 kHz < fc ≤ 100 kHz 10 MHz < fc ≤ 12 MHz < –117 dBm, Nominal < –132 dBm, Nomina
Specifications (continued) Demodulation Frequency range Carrier power accuracy Carrier power displayed resolution AM measurement Modulation rate Accuracy Depth Accuracy FM measurement Modulation rate Accuracy Supplemental information 10 MHz to 3 GHz ± 2 dB ± 1 dB 0.01 dBm Typical 20 Hz to 100 kHz 1 Hz, nominal < 0.1% modulation rate, nominal 5 to 95% ± 4% Deviation Accuracy 20 Hz to 200 kHz 1 Hz, nominal < 0.
Ordering information Model number N9340B Options N9340B-INM N9340B-XDM N9340B-IBC N9340B-PA3 N9340B-TG3 N9340B-AMA N9340B-DMA N9340B-1TC N9340B-1DN N9340B-BAT N9340B-ADP N9340B-BCG N9340B-TAD N9340B-ABA N9340B-AB2 N9340B-ABJ Warranty Select coverage Included R-51B-001-5Z Calibration Select Agilent calibration plan R-50C-011-3 R-50C-011-5 Description Handheld spectrum analyzer 100 kHz to 3.
www.agilent.com www.agilent.com/find/hsa www.agilent.com/find/n9340b myAgilent myAgilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. Three-Year Warranty www.agilent.com/find/ThreeYearWarranty Beyond product specification, changing the ownership experience. Agilent is the only test and measurement company that offers threeyear warranty on all instruments, worldwide.