Specifications
Test Record Forms
N8924A/N8944A
N8924A/N8944A Test Record Report Number ______ Date__________
Test Description Model Min. Specs Results Max. Specs
With Remote Sensing
Voltage Programming & Readback
Minimum voltage (Vout):
Voltage measured over interface:
High voltage (Vout):
Voltage measured over interface:
Both
Both
Both
Both
36.75 V
Vdmm – 750 mV
711.75 V
Vdmm – 750 mV
_______
_______
_______
_______
38.25 V
Vdmm + 750 mV
713.25 V
Vdmm + 750 mV
With Local Sensing
Voltage Programming & Readback
Minimum voltage (Vout):
Voltage measured over interface:
High voltage (Vout):
Voltage measured over interface:
Both
Both
Both
Both
36.75 V
Vdmm – 750 mV
711.75 V
Vdmm – 750 mV
_______
_______
_______
_______
38.25 V
Vdmm + 750 mV
713.25 V
Vdmm + 750 mV
CV Load Effect: Both – 375 mV _______ + 375 mV
CV Ripple and Noise
peak-to-peak:
rms:
Both
Both
N/A
N/A
_______
_______
+ 800 mV
+ 200 mV
Transient response @ 1.5 ms: Both – 7.5 V _______ + 7.5 V
Current Programming & Readback
Minimum current (Iout):
Current measured over interface:
High current (Iout):
Current measured over interface:
Both
Both
Both
Both
0.96 A
Idmm – 40 mA
18.96 A
Idmm – 40 mA
_______
_______
_______
_______
1.04 A
Idmm + 40 mA
19.04 A
Idmm + 40 mA
CC Load Effect: Both – 30 mA _______ + 30 mA
Test Description Electronic Load Setting Instrument Setting
Voltage Programming & Readback Min Voltage:
Voltage Programming & Readback High Voltage:
CV Load Effect:
CV Ripple and Noise:
Transient Response:
Current Programming & Readback Min Current:
Current Programming & Readback High Current:
CC Load Effect:
CC, 2 A
CC, 2 A
CC, 0.2 A to 19 A
CC, 19 A
CC, 2 A to 18 A
CV, 15 V
CV, 15 V
CV, 15 V to 712.5 V
37.5 V, 20 A
712.5 V, 20 A
187.5 V, 20 A
187.5 V, 20 A
187.5 V, 20 A
20 V, 1 A
20 V, 19 A
750 V, 2 A
Agilent N8900 Series Operating and Service Guide 135