Specifications
Specifications and Characteristics
Specification 10 kW
N8925A/
N8945A
N8926A/
N8946A
N8928A/
N8948A
N8929A/
N8949A
N8930A/
N8950A
DC Ratings
Voltage:
Current:
Power:
0 - 80 V
0 - 340 A
10 kW
0 - 200 V
0 - 140 A
10 kW
0 - 500 V
0 - 60 A
10 kW
0 - 750 V
0 - 40 A
10 kW
0 - 1000 V
0 - 30 A
10 kW
Output ripple & noise
1
CV rms:
CV peak-to-peak:
25 mV
320 mV
40 mV
375 mV/300 mV
70 mV
350 mV
200 mV
800 mV
350 mV
1600 mV
Load regulation
Voltage:
Current:
40 mV
510 mA
100 mV
210 mA
250 mV
90 mA
375 mV
60 mA
500 mV
53 mA/45 mA
Voltage programming &
measurement accuracy
2
≤ 80 mV ≤ 200 mV ≤ 500 mV ≤ 750 mV ≤ 1 V
Current programming &
measurement accuracy
2
≤ 680 mA ≤ 280 mA ≤ 120 mA ≤ 80 mA ≤ 60 mA
Transient response
3
Recovery Time:
Settling band:
≤ 1.5 ms
0.8 V
≤ 1.5 ms
2 V
≤ 1.5 ms
5 V
≤ 1.5 ms
7.5 V
≤ 1.5 ms
10 V
Specification 15 kW
N8931A/
N8951A
N8932A/
N8952A
N8934A/
N8954A
N8935A/
N8955A
N8937A/
N8957A
DC Ratings
Voltage:
Current:
Power:
0 - 80 V
0 - 510 A
15 kW
0 - 200 V
0 - 210 A
15 kW
0 - 500 V
0 - 90 A
15 kW
0 - 750 V
0 - 60 A
15 kW
0 - 1500 V
0 - 30 A
15 kW
Output ripple & noise
1
CV rms:
CV peak-to-peak:
25 mV
320 mV
40 mV
375 mV/300 mV
70 mV
350 mV
200 mV
800 mV
400 mV
2400 mV
Load regulation
Voltage:
Current:
40 mV
765 mA
100 mV
315 mA
250 mV
135 mA
375 mV
90 mA
750 mV
53 mA/45 mA
Voltage programming &
measurement accuracy
2
≤ 80 mV ≤ 200 mV ≤ 500 mV ≤ 750 mV ≤ 1.5 V
Current programming &
measurement accuracy
2
≤ 1.1 A ≤ 420 mA ≤ 180 mA ≤ 120 mA ≤ 60 mA
Transient response
3
Recovery Time:
Settling band:
≤ 1.5 ms
0.8 V
≤ 1.5 ms
2 V
≤ 1.5 ms
5 V
≤ 1.5 ms
7.5 V
≤ 1.5 ms
15 V
1
From 20 Hz to 300 kHz for rms noise; from 20 Hz to 20 MHz for peak-to-peak noise
2
Accuracy specifications are warranted at 23°C ±5°C
3
Time to recover to within the settling band following a load change from 10% to 90% of full load
10 Agilent N8900 Series Operating and Service Guide