Product specifications

72
Supplemental characteristics
for all model numbers
DC floating voltage: All outputs can be
floated up to ±240 VDC from chassis
ground
Remote sensing: Up to 1 V drop per
load lead. The drop in the load leads is
subtracted from the voltage available
for the load.
Command processing time: 7 ms typical
with front-panel display disabled
Down programming: Current sink limits
are fixed approximately 10% higher than
source limits for a given operating
voltage above 2.5 V
Input power: 550 W max., 720 VA max.
GPIB interface capabilities: SH1, AH1, T6,
L4, SR1, RL1, PP1, DC1, DT0.
Software driver:
VXIPlug&Play
Regulatory compliance: Listed to UL1244;
conforms to IEC 61010-1; carries the CE
mark.
Size: 425.5 mm W x 132.6 mm H x
497.8 mm D (16.75 in x 5.22 in x 19.6 in)
Weight: Net, 17.4 kg (38 lb);
shipping, 22.7 kg (50 lb)
Warranty: One year
Ordering information
Opt 100 87 to 106 VAC, 47 to 66 Hz input,
6.3 A (Japan only)
Opt 120 104 to 127 VAC, 47 to 63 Hz
Opt 220 191 to 233 VAC, 47 to 66 Hz, 3.0 A
Opt 240 209 to 250 VAC, 47 to 66 Hz, 3.0 A
Opt 750 Relay Control and DFI/RI
Opt S50 similar to option 750,
however the remote inhibit does
not latch
* Opt 908 Rack-mount kit (p/n 5062-3977)
* Opt 909 Rack-mount kit with handles
(p/n 5063-9221)
Opt 0L1 Full documentation on
CD-ROM, and printed standard
documentation package
Multiple-Output: 40 W-105 W GPIB (Continued)
Spe cif icati ons
(at 0° to 55°C unless
otherwise specified)
40 W 40 W 80 W 80 W 105 W
output output output output output
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average programming Voltage 6 mV 15 mV 6 mV 6 mV 10.5 mV
resolution
20 mV (high) 20 mV (high)
Current 25 mA 10 mA 50 mA 50 mA 15 mA
20 mA (high) 20 mA (high)
OVP 100 mV 250 mV 100 mV 2 50 mV 175 mV
Output programming response time 2 ms 6 ms 2 ms 6 ms 6 ms
(time to settle within 0.1% of full scale output,
after Vset command has been processed)
More detailed specifications at
www.agilent.com/find/6620
High Performance DC Power Supplies speed and accuracy for test optimization
Opt 0L2 Extra copy of standard
printed documentation package
Opt 0B0 Full documentation on
CD-ROM only
Opt 0B3 Service manual
* Support rails required
Output 2 Output 4
Output 3 Output 1
Top
Terminal Strip Detail
Output 2 & 3
Side
Rear
Output 1 & 4
425.5 mm
16.75"
497.8 mm
19.6"
518.2 mm
20.4"
128 mm
5.04"
-O V +O V -S
-V +V +S
+S +V -V +S +O V
-O V
12.7 mm
0.5"
132.6 mm
5.2"
Screw Size:
M35 x 0.6
Output 2 Output 4
Output 3 Output 1
Top
Terminal Strip Detail
Output 2 & 3
Side
Rear
Output 1 & 4
425.5 mm
16.75"
497.8 mm
19.6"
518.2 mm
20.4"
128 mm
5.04"
-O V +O V -S -V +V +S
+S +V -V +S +O V
-O V
12.7 mm
0.5"
132.6 mm
5.2"
Screw Size:
M3.5 x 0.6
Agilent Models: 6621A, 6622A, 6623A, 6624A, 6627A
Accessories
p/n 1494-0059 Rack slide kit
E3663A Support rails for
Agilent rack cabinets