Product specifications

53
Application notes
10 Practical Tips You Need to
Know About Your Power Products
5965-8239E
Understanding Linear
Power Supply Operation
(AN1554)
5989-2291EN
Agilent DC Power Supplies
for Base Station Testing
5988-2386EN
Single-Output: 500 W (Continued)
Spe cif icati ons
(at 0° to 55°C unless
otherwise specified)
More detailed specifications at
www.agilent.com/find/6550
High Performance DC Power Supplies speed and accuracy for test optimization
6551A-J01 6551A-J03 6553A-J04 6553A-J17
Special order Special order Special order Special order
option option option option
Number of outputs 1 1 1 1
GPIB No No No No
Output ratings
Output voltage 10 V 6 V 40 V 30 V
Output current (40°C) 50 A 60 A 12.5 A 17.5 A
Maximum current (50°C/55°C)
45 A/42.5 A 54 A/51 A 11.25 A/10.6 A 15.75 A/14.87 A
Programming accuracy
at 25°C ±5°C
Voltage 0.06% + 6 mV 5 mV 17.5 mV 15 mV
Current 0.15% + 60 mA 75 mA 13 mA 16 mA
Ripple and noise
from 20 Hz to 20 MHz
Voltage rms 300 µV 300 µV 1.6 mV 400 µV
peak-peak 3 mV 3 mV 5 mV 4 mV
Current rms 25 mA 30 mA 5 mA 6 mA
Load regulation
Voltage 1 mV 1 mV 3.5 mV 3 mV
Current 2 mA 6.5 mA 1 mA 0.5 mA
Line regulation
Voltage 0.5 mV 0.5 mV 1 mV 1 mV
Current 2 mA 2 mA 0.75 mA 0.75 mA
Transient response time Less than 100 µs for the output voltage to recover to its previous level
(within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater)
following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 2.5 mV 2 mV 12 mV 10 mV
Current 15 mA 18 mA 4 mA 5 mA
OVP 16 mV 12 mV 65 mV 54 mV
OVP accuracy 200 mV 160 mV 750 mV 700 mV