Product specifications

28
Extensive device protection
To safeguard your device from
damage, the N5700 series power
supplies provide over-temperature,
over-current and over-voltage pro-
tect (OVP) to shut down the power
supply output when a fault occurs.
They also offer an undervoltage
limit (UVL) that prevents adjust-
ment of the output voltage below
a certain limit. The combination
of UVL and OVP capabilities lets
you create a protection window
for sensitive load circuitry.
Simplify system connection
The N5700 offers many system
oriented features to simplify and
accelerate test system development.
They support the industry standard
SCPI commands and come standard
with software drivers.
With built-in GPIB, Ethernet/LAN,
and USB 2.0 interfaces, the N5700
gives you the flexibility to use your
I/O interface of choice today and
in the future.
Additionally, the built-in Web
server lets you operate, configure,
and monitor the N5700 remotely
via a standard browser such as
Microsoft Internet Explorer.
Command compatibility
The N5700 includes a compatibility
command set for the Xantrex XFR
series power supplies, the Sorensen
DLM series power supplies, and the
Agilent 603x series power supplies.
This simplifies system integration
when converting to the N5700.
Single-Output 750 W & 1500 W GPIB, LAN, USB
(Continued)
More detailed specifications at
www.agilent.com/find/N5700
Basic DC Power Supplies essential features for a tight budget
Supplemental Characteristics
(Non-warranted characteristics determined by design
that are useful in applying the product)
Output response time
(settle to within ±1.0% of the
rated output, with a resistive load)
Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s
Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s
Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s
Remote sense compensation
Volts/load lead 1 V 1 V 1 V 1 V 1.5 V 2 V
Output ripple and noise
2
CC rms 200 mA 180 mA 120 mA 76 mA 63 mA 48 m
Programming resolution/
measurement resolution
Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV
Current 12 mA 10.8 mA 7.2 mA 4.56 mA 3 mA 2.3 mA
N5741A N5742A N5743A N5744A N5745A N5746A
Spe cif icati ons
(at 0° to 55°C unless
otherwise specified)
Notes:
2
From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load
(for 6 V units from 33% to 100% of output voltage)
+S+LS NC-LC-S
SW1
GPIB
ANALO G PROGR AMMING
NOT A CTIVE
AC IN PUT
J2
J1
TX
LINK
ON
OFF
10/10 0 Ethern et
422.8 mm
+V –V
1 2 3 4 5 6 7 8 9
DC AMPSDC VOLTS
PROT FINE LIMIT
POWER
UVL
OVP
OCP REM OUT ON
VOLTAGE CURRENT
N5749A
100 V / 7.5 A / 750 W
Sytem DC Power Supply
482.8 mm
43.6 mm
507.0 mm
433.0 mm
57.8
mm
92.0 mm 92.0 mm
21.0 mm
A A A