Product specifications

More protection, more convenience —
for less
It’s often difficult to find a power
supply that is just right for your
test requirements and your budget.
Whether you’re manufacturing
consumer products, testing
electronic components, or simply
looking for reliable, affordable
power, Agilent’s family of basic
power supplies now includes single
output, non-programmable models
in the 90 W to 150 W power range.
With capabilities typically found
only in programmable supplies, you
get excellent value along with great
efficiency in your work. As a result,
you can minimize setup time and
measurement errors and maximize
device reliability. You’ll get the right
power with a difference — backed by
stringent safety certifications and
Agilent quality standards — at an
affordable price.
The Agilent U8000 Series offers
90 W to 150 W single output, non-
programmable DC power supplies
that include features typically found
only in costly programmable
supplies. The U8000 Series delivers
excellent value by providing reliable
DC power, efficient setup capabilties,
and important security features that
let you address a variety of applica-
tions in electronics manufacturing
and educational settings.
Basic DC Power Supplies essential features for a tight budget
Spe cif icati ons U8001A U8002A
(at 0° to 40°C unless
otherwise specified)
More detailed specifications at
www.agilent.com/find/lowcostpower
14
90 W to 150 W outputs, up to 30 V and 5 A
Single output models in half rack width size
Low noise, linear regulation
Single range output provides more current at lower voltage settings
U8001A-U8002A
Single-Output
90-150 W
Output ratings (at 0°C to 40°C) 0 to +30 V 0 to +30 V
0 to 3 A 0 to 5 A
Line and load regulation CV: <0.01% +2 mV CV: <0.01% +2 mV
CC: <0.02% +2 mA CC: <0.02% +2 mA
Ripple and noise (25°C ±5°C) CV: 12 mVp-p, <1 mVrms; CV: 12 mVp-p, <1 mVrms;
CC: 3 mArms CC: 3 mArms
Load transient response time <50 µs <50 µs
(within 15 mV from full load to half load
and from half load to full load)
Programming accuracy
1
(25°C ±5°C) <0.35% +20 mV <0.35% +20 mV
<0.35% +20 mA <0.35% +20 mA
Readback accuracy
1
(25°C ±5°C) <0.35% +20 mV <0.35% +20 mV
<0.35% +20 mA <0.35% +20 mA
Meter resolution Voltage: 10 mV Voltage: 10 mV
Current: 10 mA Current: 10 mA
Maximum output float voltage ±240 VDC ±240 VDC
Supplemental Characteristics
(Non-warranted characteristics determined by design
that are useful in applying the product)
Temperature coefficient (for 12 months) CV: <100 ppm/ °C CV: <100 ppm/ °C
CC: <380 ppm/ °C CC: <380 ppm/ °C
Output voltage overshoot <1 V <1 V
(during turn-on or turn-off of AC power state
with the output control set to less than 1 V)
Voltage programming speed,
to within 1% of total excursion
Up full load 150 ms 150 ms
No load 100 ms 100 ms
Down full load 30 ms 30 ms
No load 450 ms 450 ms
Last memory setting enabled Yes Yes
Overvoltage protection response time <1.5 ms when the trip voltage is equal to or greater
than 3 V and <10 ms when the trip voltage is less than
3 V (average time for output to drop from 90% of
output voltage to 1 V after OVP condition occurred)