Product specifications

DC Power Supply
Feature Description Index
(Continued)
For more detailed specifications see the product manual at
www.agilent.com/find/power
12
DC range Max
200 W- 40 W- 40 W & 25 W & 200 W- 2000 W- 1200 W 30 W-
700 W- 50 W-
power
1000 W 100 W 80 W 50 W 500 W 6600 W 200 W 5000 W 500 W
Max voltage 500 V 100 V 50 V 50 V 120 V 120 V 200 V 60 V 600 V 150 V
Max current 120 A 10 A 10 A 2 A 50 A 875 A 16 A 20 A 400 A 50 A
Page 24 38, 40 71 73 42, 48
56
, 67, 69
88 20, 22 27, 32 75
Protection Features (Continued)
Discrete fault indicator/
• •
O
O
• • • • •
remote inhibit (DFI/RI)
Using these digital ports, power supplies
can be connected independently of the
GPIB. If any one experiences an error
condition (overvoltage, for example),
it can signal the other units to also
downprogram their outputs.
O = Optional
SRQ
• • • • • • • • •
Almost any fault condition or change of
state of the power supply can be enabled
to generate an SRQ. This signals the
computer to take the appropriate action.
Local lockout
• • • • • • • • • •
Front-panel or keyboard control can be
disabled. This keeps unauthorized operators
from changing the programmed states.
Fan-speed control
• • • • • •
Controls the fan-speed to provide only the
required cooling, reducing unnecessary
acoustic noise.
O = Optional
Active down-programming
•
P 6610-P F F P P P P
Active circuits quickly drain the energy 6630-F N6750
from the output when unit is programmed N6760
to a lower voltage. This means that a unit Only
under test can be safely removed from its
test fixture without danger of arcing.
F = Full-rated output current
P = Less than 100% rated output current
Maintenance Features
Electronic calibration in the rack
• • • • • • • • •
Calibration requires no internal adjustments.
Calibration security
•
P, S J J P, J P, J P, S P, J
*
*
Units can be protected from accidental P P
access to calibration routines by either a
password (P) or an internal jumper (J )
or switch (s).
Self-test
• • • • • • • • • •
Extensive self-test is triggered
automatically on power-up. Additional
tests can be initialed by user programming
or front-panel control.
*A nonvolatile status in SCPI mode only.
6030 Series Autorangers
6610 & 6630 Series Single-Output
6620 Series Multiple-Output
6620 Series Precision Multiple-Output
6640 & 6650 Series Single-Output
6670-6690 Series Single-Output
66000 Modular Power Systems
E3630 & E3640 Series Single & Multiple-Output
N5700 & N8700 Series Single-Output
N6700 Modular Power System Family