Product specifications

DC Power Supply
Feature Description Index
(Continued)
For more detailed specifications see the product manual at
www.agilent.com/find/power
11
DC range Max
200 W- 40 W- 40 W & 25 W & 200 W- 2000 W- 1200 W 30 W-
700 W- 50 W-
power
1000 W 100 W 80 W 50 W 500 W 6600 W 200 W 5000 W 500 W
Max voltage 500 V 100 V 50 V 50 V 120 V 120 V 200 V 60 V 600 V 150 V
Max current 120 A 10 A 10 A 2 A 50 A 875 A 16 A 20 A 400 A 50 A
Page 24 38, 40 71 73 42, 48
56
, 67, 69
88 20, 22 27, 32 75
GPIB Programming Features
GPIB programming of voltage and current
• • • • • • • • • •
Self-documenting programming commands GPIB GPIB
mean that programming is done in units LAN LAN
of volts and amps, not in percentages or USB USB
binary representations.
Measured voltage and current
• • • • • • • • • •
read-back over the GPIB
The output is read back in
units of volts and amps.
Store-recall states
•
Complete operating states can be stored
in nonvolatile memory. Each state specifies
not only the output voltage and current,
but also many of the programmable
protection features.
Number nonvolatile states 0 4 0 4 5 6670-5 5 E363x-3 1 2
(One of these states is automatically 6680-4 E364x-5
accessed on turn-on) 6690-4
Number volatile states 16/5 0 10 7 0 0 5 0 16 0
Standard Commands for Programmable
• • • • • • • •
Instruments (SCPI)
SCPI is the standard language for test and
measurement equipment. Standard codes
make a software writing and maintenance
more efficient. For example, using this
standard, the output voltage of the power
supply is measured with the same command
(MEASURE: VOLTAGE?) by either a DMM
or a power supply.
Protection Features
GPIB programmable overvoltage protection M
•
T T
•
•
T
•
T T
Can be enabled to quickly down-program M
the output and set SRQ and/or DFI/RI.
T = Can generate trigger.
M = Overvoltage, the level is set manually
with a front-panel control.
GPIB programmable overcurrent protection
•
•
• • • •
T
E3632A T T
Can be enabled to quickly down-program E3633A
the output and set SRQ and/or DFI/RI. E3634A
T = Can generate trigger.
Overtemperature protection
•
•
• • • •
T
T T
Will down-program the output and can
be enabled to set SRQ and/or DFI.
T = Can generate trigger.
6030 Series Autorangers
6610 & 6630 Series Single-Output
6620 Series Multiple-Output
6620 Series Precision Multiple-Output
6640 & 6650 Series Single-Output
6670-6690 Series Single-Output
66000 Modular Power Systems
E3630 & E3640 Series Single & Multiple-Output
N5700 & N8700 Series Single-Output
N6700 Modular Power System Family