Product specifications

DC Power Supply
Feature Description Index
(Continued)
For more detailed specifications see the product manual at
www.agilent.com/find/power
11
DC range Max
200 W- 40 W- 40 W & 25 W & 200 W- 2000 W- 1200 W 30 W-
700 W- 50 W-
power
1000 W 100 W 80 W 50 W 500 W 6600 W 200 W 5000 W 500 W
Max voltage 500 V 100 V 50 V 50 V 120 V 120 V 200 V 60 V 600 V 150 V
Max current 120 A 10 A 10 A 2 A 50 A 875 A 16 A 20 A 400 A 50 A
Page 24 38, 40 71 73 42, 48
56
, 67, 69
88 20, 22 27, 32 75
GPIB Programming Features
GPIB programming of voltage and current
Self-documenting programming commands GPIB GPIB
mean that programming is done in units LAN LAN
of volts and amps, not in percentages or USB USB
binary representations.
Measured voltage and current
read-back over the GPIB
The output is read back in
units of volts and amps.
Store-recall states
Complete operating states can be stored
in nonvolatile memory. Each state specifies
not only the output voltage and current,
but also many of the programmable
protection features.
Number nonvolatile states 0 4 0 4 5 6670-5 5 E363x-3 1 2
(One of these states is automatically 6680-4 E364x-5
accessed on turn-on) 6690-4
Number volatile states 16/5 0 10 7 0 0 5 0 16 0
Standard Commands for Programmable
Instruments (SCPI)
SCPI is the standard language for test and
measurement equipment. Standard codes
make a software writing and maintenance
more efficient. For example, using this
standard, the output voltage of the power
supply is measured with the same command
(MEASURE: VOLTAGE?) by either a DMM
or a power supply.
Protection Features
GPIB programmable overvoltage protection M
T T
T
T T
Can be enabled to quickly down-program M
the output and set SRQ and/or DFI/RI.
T = Can generate trigger.
M = Overvoltage, the level is set manually
with a front-panel control.
GPIB programmable overcurrent protection
T
E3632A T T
Can be enabled to quickly down-program E3633A
the output and set SRQ and/or DFI/RI. E3634A
T = Can generate trigger.
Overtemperature protection
T
T T
Will down-program the output and can
be enabled to set SRQ and/or DFI.
T = Can generate trigger.
6030 Series Autorangers
6610 & 6630 Series Single-Output
6620 Series Multiple-Output
6620 Series Precision Multiple-Output
6640 & 6650 Series Single-Output
6670-6690 Series Single-Output
66000 Modular Power Systems
E3630 & E3640 Series Single & Multiple-Output
N5700 & N8700 Series Single-Output
N6700 Modular Power System Family