Product specifications

113
For a sine wave with a resistive
load at 0° to 40° C, within an output
frequency range of 45 Hz to 1000 Hz,
and in AC coupled mode after a
30 minute warm-up unless
otherwise noted.
Notes:
1
Product may be operated between
DC and 45 Hz subject to certain
deratings. Measurements may be
extended to 4.5 Hz at full accuracy
only by selecting a digitization rate
of 250 µ seconds per point. Frequency
content of the measured signal must
be limited to 4 kHz or less to avoid
aliasing effects.
2
Select low measurement range
for improved accuracy (10:1)
for lower power measurements.
AC Power Source/Analyzers: 375-1750 VA
(Continued)
Spe cif icati ons
(at 0° to 55°C unless
otherwise specified)
More detailed specifications at
www.agilent.com/find/6800
AC Power Source/Analyzers an integrated AC power solution
6811B 6812B 6813B
Measurement Accuracy (
25°C
±
55°C)
Rms. voltage (45 - 100 Hz) 0.03% + 100 mV
1
0.03% + 100 mV
1
0.03% + 100 mV
1
DC voltage 0.05% + 150 mV
1
0.05% + 150 mV
1
0.05% + 150 mV
1
RMS current (45 - 100 Hz)
2
High range 0.05% + 10 mA 0.05% + 10 mA 0.05% + 10 mA
Low range 0.05% + 1.5 mA 0.05% + 1.5 mA 0.05% + 1.5 mA
Power (VA) (45-100 Hz)
2
0.1% + 1.5 VA + 0.1% + 1.5 VA + 0.1% + 1.5 VA +
High range 12 mVA/V 12 mVA/V 12 mVA/V
Low range 0.1% + 1.5 VA + 0.1 % + 1.5 VA + 0.1% + 1.5 VA +
1.2 mVA/V 1.2 mVA/V 1.2 mVA/V
Power (watts) (45-100 Hz)
2
0.1% + 0.3 W + 0.1% + 0.3 W + 0.1% + 0.3 W +
High range 12 mW/V 12 mW/V 12 mW/V
Low range 0.1% + 0.3 W + 0.1% + 0.3 W + 0.1% + 0.3 W +
1.2 mW/V 1.2 mW/V 1.2 mW/V
Frequency 0.01% + 0.01 Hz 0.01% + 0.01 Hz 0.01% + 0.01 Hz
Power factor 0.01 0.01 0.01
Current magnitude Fundamental 0.03% + 1.5 mA 0.03% + 1.5 mA 0.03% + 1.5 mA
Low range Harmonics 2-49 0.03% + 1 mA + 0.03% + 1 mA + 0.03% + 1 mA +
0.2%/kHz 0.2%/kHz 0.2%/kHz
Current magnitude Fundamental 0.05% + 5 mA 0.05% + 5 mA 0.05% + 5 mA
High range Harmonics 2-49 0.05% + 3 mA + 0.05% + 3 mA + 0.05% + 3 mA +
0.2%/kHz 0.2%/kHz 0.2%/kHz
Supplemental Characteristics (Non-warranted characteristics determined by design that are
useful in applying the product)
Average programming accuracy
(% of output + offset) rms current 1.2% + 50 mA 1.2% + 50 mA 1.2% + 50 mA
Average programming resolution
rms voltage 125 mV 125 mV 125 mV
DC voltage 250 mV 250 mV 250 mV
Overvoltage programming (OVP) 2 V peak 2 V peak 2 V peak
rms current 2 mA 4 mA 4 mA
Peak current 12.5 mA 25 mA 25 mA
Output frequency 10 µHz 10 µHz 10 µHz
Phase N/A N/A N/A