101
Multiple-Input: 150 W to 600 W (Continued)
N3300A N3301A
Operating temperature range 0°C to 55°C 0°C to 55°C
Input ratings
Operating range 100 - 250 VAC 100 - 250 VAC
48 - 63 Hz 48 - 63 Hz
Input current 4.2 A @ 100 - 127 VAC 2.3 A @ 100 - 250 VAC
2.2 A @ 200 - 250 VAC
Input VA 440 VA 230 VA
Inrush current 38 A 18 A @ 115 VAC
36 A @ 230 VAC
More detailed specifications at
www.agilent.com/find/N3300
DC Electronic Loads maximize throughput with real-life loading conditions
Table A-3
Supplemental Characteristics
Supplemental characteristics
for all model numbers
Analog programming bandwidth:
10 kHz (-3 db frequency) in CC mode only
Analog programming voltage:
Voltage: 0 - 10 V
Current: 0 - 10 V
Analog monitor ports:
Voltage: 0 - 10 V
Current: 0 - 10 V
Remote sensing:
5 VDC between sense and load input
Digital/trigger inputs:
V
il
= 0.9 V max at I
il
= -1 mA
V
ih
- 3.15 V min
(pull-up resistor on input)
Digital/trigger outputs:
V
ol
= 0.72 V max at I
ol
= 1 mA
V
oh
= 4.4 V min at I
oh
= -20 µA
Agilent Models: N3300A
425.5 mm
16.75"
571.5 mm
22.5"
177.8 mm
7.0"
50.8 mm
2.0"
190.5 mm
7.5"
12.7 mm
0.5"
Top
Side
Rear