Product specifications

100
Multiple-Input: 150 W to 600 W (Continued)
Table A-2 (Continued)
Supplemental Characteristics
Table A-2 lists the supplemental
characteristics, which are not
warranted but are descriptions of
typical performance determined
either by design or type testing.
Notes
2
Applies to all ranges.
N3302A N3303A N3304A N3305A N3306A N3307A
Programmable short
66 mΩ max. 200 mΩ max. 33 mΩ max. 33 mΩ max. 17 mΩ max. 33 mΩ max.
40 mΩ 100 mΩ 20 mΩ 25 mΩ 12 mΩ 20 mΩ
typical typical typical typical typical typical
Programmable open ≥20 kΩ ≥80 kΩ ≥20 kΩ ≥20 kΩ ≥20 kΩ ≥80 kΩ
Command processing time
Using discrete commands 3 ms 3 ms 3 ms 3 ms 3 ms 3 ms
Using list commands 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms
List dwell characteristics
Range 0 - 10 s 0 - 10 s 0 - 10 s 0 - 10 s 0 - 10 s 0 - 10 s
Resolution 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms
Accuracy 5 ms 5 ms 5 ms 5 ms 5 ms 5 ms
Measurement time
1000 samples (default) 20 ms 20 ms 20 ms 20 ms 20 ms 20 ms
(with specified (with specified (with specified (with specified (with specified (with specified
measurement measurement measurement measurement measurement measurement
accuracy) accuracy) accuracy) accuracy) accuracy) accuracy)
200 samples 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms
(with <6% (with <6% (with <6% (with <6% (with <6% (with <6%
additional additional additional additional additional additional
fixed offset) fixed offset) fixed offset) fixed offset) fixed offset)
fixed offset)
100 samples 9 ms 9 ms 9 ms 9 ms 9 ms 9 ms
(with <10% (with <10% (with <10% (with <10% (with <10% (with <10%
additional additional additional additional additional additional
fixed offset) fixed offset) fixed offset) fixed offset) fixed offset) fixed offset)
20 points 7 ms 7 ms 7 ms 7 ms 7 ms 7 ms
(with <30% (with <30% (with <30% (with <30% (with <30% (with <30%
additional additional additional additional additional additional
fixed offset) fixed offset) fixed offset) fixed offset) fixed offset) fixed offset)
<20 points 7 ms 7 ms 7 ms 7 ms 7 ms 7 ms
(with >30% (with >30% (with >30% (with >30% (with >30% (with >30%
additional additional additional additional additional additional
fixed offset) fixed offset) fixed offset) fixed offset) fixed offset) fixed offset)
Ripple and noise (20 Hz - 10 MHz)
Current (rms/peak to peak)
2 mA/20 mA 1 mA/10 mA 4 mA/40 mA 4 mA/40 mA 6 mA/60 mA 2 mA/20 mA
Voltage (rms) 5 mV
rms
12 mV
rms
6 mV
rms
10 mV
rms
8 mV
rms
10 mV
rms
External analog programming
Voltage programming accuracy
2
0.5% + 12 mV 0.5% + 48 mV 0.5% + 12 mV 0.5% + 30 mV 0.5% + 12 mV 0.5% + 30 mV
Current programming accuracy
2
0.25% + 4.5 mA 0.25% + 1.5 mA 0.25% + 9 mA 0.25% + 9 mA 0.25% + 18 mA 0.25% + 4.5 mA
External monitor ports
Voltage monitor accuracy
0.25% + 12 mV 0.25% + 48 mV 0.25% + 12 mV 0.25% + 30 mV 0.25% + 12 mV 0.25% + 30 mV
Current monitor accuracy
0.1% + 4.5 mA 0.1% + 1.5 mA 0.1% + 9 mA 0.1% + 9 mA 0.1% + 18 mA 0.1% + 4.5 mA
More detailed specifications at
www.agilent.com/find/N3300