Specifications

Load Transient Recovery (assumes standard
GSM pulse test as defined in the figure below)
Transient Voltage Dip
3
75 mV 75 mV
Time
4
< 45 μs < 45 μs
Transient Voltage Dip with Disconnect Rely installed
90 mV 90 mV
Time with Disconnect Relay Installed
4
< 75 μs < 75 μs
Remote Sense Capability
Outputs can maintain DC specifications with up to a 0.5-volt drop per load lead.
Maximum sense lead resistance is limited to 300 mΩ/lead.
Down-programming Capability
Continuous power 12 W 12 W
Continuous current
5
2 A 2 A
Supplemental
N6783A-BAT N6783A-MFG
Characteristics
93
The N6783A-MFG, when used in
the N6700B Low-Profile mainframe,
offers industry-leading output den-
sity with up to 4 outputs in 1U of
rack space. GPIB, LAN, USB, and
LXI Class C compliance are standard.
Part of a Modular Power System
The N6783A-BAT and N6783A-MFG
modules can be used with the N6700
low-profile mainframes for auto-
mated test and with the N6705 DC
power analyzer mainframe for R&D.
Select from more than 20 different
DC power modules ranging in capa-
bility from basic to high precision,
and in power from 20-300 W; see
N6700 Low Profile Modular Power
System section for details.
Ordering Information
N6783A-BAT Battery Charge/Discharge
Module
N6782A-MFG Mobile Communications
DC Power Module
N6705B-056 Software License to Control
N6705A/B with 14585A Control and
Analysis Software (Option to the N6705B
when ordered new)
N6705U-056 Upgrade an N6705A/B DC
Power Analyzer with14585A Software
License
Application Specific Modules
N6783A-BAT, N6783A-MFG (Continued)
More detailed specifications at www.agilent.com/find/N6783A-BAT
www.agilent.com/find/N6783A-MFG
Application Specific DC Power Supplies tailored solutions for specific needs
Notes:
3
Voltage measured at the sense point
4
Time for the output to recover to 20 mV below its final setting
5
Applies above 0.50 V out
N6700B - N6702B
N6705B