Technical data
482 Agilent N8201A Performance Downconverter Synthetic Instrument Module, 250 kHz to 26.5 GHz
24 System
:DISPlay:ANNotation:CLOCk:DATE:FORMat?
Example:
DISP:ANN:CLOC:DATE:FORM DMY
Set Time
Enables you to set the time of the real-time clock. Enter the time in 24 hour HHMMSS format.
Key Path: System, Time/Date
State Saved: Survives Preset and power cycle, but not saved in Instrument State.
Range:
Hour (HH): 00 to 23.
Minute (MM): 00 to 59.
Second (SS): 00 to 59.
Remote Command:
:SYSTem:TIME <hour>,<minute>,<second>
:SYSTem:TIME?
Example:
SYST:TIME 12,42,00 Sets the clock to 12:42:00 PM.
Adjust Time Setting (Remote Command Only)
Adjust the instruments internal time by the value entered.
Key Path: System, Time/Date
DefaultTerminator seconds
Remote Command:
:SYSTem:TIME:ADJust <seconds>
Example:
SYST:TIME:ADJ 3600 will advance the time one hour.
SYST:TIME:ADJ -86400 will back the date up one day, without changing the time of
day (minutes or seconds).