Technical data
Measurement Setup 15
Agilent N8201A Performance Downconverter Synthetic Instrument Module, 250 kHz to 26.5 GHz 297
Optimize Ref Level
Sets the input attenuator and reference level to optimize the robustness of the
measurement, in which it is free from errors due to input compression and log amp range
limitations. The input attenuator setting will not necessarily give the optimum dynamic
range, nor the optimum accuracy. No single setting can optimize both, and the optimum
setting often depends on the signal characteristics.
There will always be a minimum of 2 dB of attenuation set to protect the N8201A input.
Key Path: Meas Setup
State Saved: Not saved.
Remote Command:
[:SENSe]:POWer[:RF]:RANGe:AUTO ONCE
Example:
POW:RANG:AUTO ONCE