Technical data
Measurement Setup 15
Agilent N8201A Performance Downconverter Synthetic Instrument Module, 250 kHz to 26.5 GHz 293
Ref BW
Sets the reference bandwidth (integration bandwidth) for each offset.
Key Path: Meas Setup, Offset Setup
State Saved: Saved in Instrument State.
Factory Preset: 2 MHz, if no radio standard (None) is selected.
If a radio standard is selected, the default value is defined by the selected standard. This
command, along with commands
[:SENSe]:ACPower:OFFSet:LIST[:FREQuency] and
[:SENSe]:ACPower:OFFSet:LIST:STATe are used to set an entire array of
values. The following table shows the default array if no radio standard (None) is selected.
Default Terminator: Hz
Range: 300 Hz to 500 MHz
Remote Command:
[:SENSe]:ACPower:OFFSet:LIST:BANDwidth|BWIDth
[:INTegration] <bw>,<bw>,<bw>,<bw>,<bw>,<bw>
[:SENSe]:ACPower:OFFSet:LIST:BANDwidth|BWIDth
[:INTegration]?
Remote Command Notes: If a radio standard is selected, the default value is defined by
the selected standard. This command, along with commands
[:SENSe]:ACPower:OFFSet:LIST[:FREQuency] and
[:SENSe]:ACPower:OFFSet:LIST:STATe are used to set an entire array of
values. The following table shows the default array if no radio standard (None) is selected.
Offset State Frequency Integ. BW
A ON 3 MHz 2 MHz
B OFF 0 Hz 2 MHz
C OFF 0 Hz 2 MHz
D OFF 0 Hz 2 MHz
E OFF 0 Hz 2 MHz
F OFF 0 Hz 2 MHz
Offset State Frequency Integ. BW
A ON 3 MHz 2 MHz